Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Common Cause Failure Analysis for Nuclear Power Plant Instrumentation and Control Systems

This presentation is prepared for the IAEA Virtual Consultancy Meeting on Preparation of a Coordinated Research Project on Common Cause Failures in Nuclear Power Plant Instrumentation and Control Systems from February 5 ? 8, 2024. It provides an overview of the INL activities on the common cause failure analysis for instrumentation and control system in nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

In-device Battery Failure Analysis

Lithium-ion batteries are indispensable power sources for a wide range of modern electronic devices. However, battery lifespan remains a critical limitation, directly affecting the sustainability and user experience. Conventional battery failure analysis in controlled lab settings may not capture the complex interactions and environmental factors encountered in real-world, in-device operating conditions. Here, this study analyzes the failure of commercial wireless earbud batteries as a model system within their intended usage context. Through multiscale and multimodal characterizations, the degradations from the material level to the device level are correlated, elucidating a failure pattern that is closely tied to the specific device configuration and operating conditions. The findings indicate that the ultimate failure mode is determined by the interplay of battery materials, cell structural design, and the in-device microenvironment, such as temperature gradients and their fluctuations. This holistic, in-device perspective on environmental influences provides critical insights for battery integration design, enhancing the reliability of modern electronics.

36 MATERIALS SCIENCE↗

Failure Analysis of Nonvolatile Residue (NVR) Analyzer Model SP-1000

National Aeronautics and Space Administration (NASA) subcontractor Wiltech contacted the NASA Electrical Lab (NE-L) and requested a failure analysis of a Solvent Purity Meter; model SP-IOOO produced by the VerTis Instrument Company. The meter, used to measure the contaminate in a solvent to determine the relative contamination on spacecraft flight hardware and ground servicing equipment, had been inoperable and in storage for an unknown amount of time. NE-L was asked to troubleshoot the unit and make a determination on what may be required to make the unit operational. Through the use of general troubleshooting processes and the review of a unit in service at the time of analysis, the unit was found to be repairable but would need the replacement of multiple components.

Potter, Joseph C.↗

Interfacing LabVIEW With Instrumentation for Electronic Failure Analysis and Beyond

The Laboratory Virtual Instrumentation Engineering Workstation (LabVIEW) software is designed such that equipment and processes related to control systems can be operationally lined and controlled by the use of a computer. Various processes within the failure analysis laboratories of NASA's Kennedy Space Center (KSC) demonstrate the need for modernization and, in some cases, automation, using LabVIEW. An examination of procedures and practices with the Failure Analaysis Laboratory resulted in the conclusion that some device was necessary to elevate the potential users of LabVIEW to an operational level in minimum time. This paper outlines the process involved in creating a tutorial application to enable personnel to apply LabVIEW to their specific projects. Suggestions for furthering the extent to which LabVIEW is used are provided in the areas of data acquisition and process control.

Buchanan, Randy K.↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

The Reconstruction and Failure Analysis of the Space Shuttle Columbia

Several days following the Columbia accident a team formed and began planning for the reconstruction of Columbia. A hangar at the Kennedy Space Center was selected for this effort due to it's size, available technical workforce and materials science laboratories and access to the vehicle ground processing infrastructure. The Reconstruction team established processes for receiving, handling, decontamination, tracking, identifying, cleaning and assessment of the debris. Initially, a 2-dimensional reconstruction of the Orbiter outer mold line was developed. As the investigation progressed fixtures which allowed a 3-dimensional reconstruction of the forward portions of the left wing's leading edge was developed. To support the reconstructions and forensic analyses a Materials and Processes (M&P) 'team was formed. This M&P team established processes for recording factual observations, debris cleaning, and engineering analysis. Fracture surfaces and thermal effects of selected airframe debris were assessed, and process flows for both nondestructive and destructive sampling and evaluation of debris were developed. The Team also assessed left hand airframe components that were believed to be associated with a structural breach of Columbia. A major portion of this analysis was evaluation of metallic deposits were prevalent on left wing leading edge components. Extensive evaluation of the visual, metallurgical and chemical nature of the deposits provided conclusions that were consistent with the visual assessments and interpretations of the NASA lead teams and the findings of the Columbia Accident Investigation Board. Analytical data collected by the M&P Team showed that a significant thermal event occurred at the left wing leading edge in the proximity of LH RCC Panels 8-9, and a correlation was formed between the deposits and overheating in these areas to the wing leading edge components. The analysis of deposits also showed exposure to temperatures in excess of 1649 C (3200 F), which would severely degrade support structure, tiles, and RCC panel materials. The integrated failure analysis of wing leading edge debris and deposits strongly supported the hypothesis that a breach occurred at LH RCC Panel 8.

Russell, Richard↗

Failure analysis and design principles of silicon-based lithium-ion batteries using micron-sized porous silicon/carbon composite

Significant progresses have been made to overcome the fundamental challenges in silicon (Si)-based lithium-ion batteries (LIBs). However, much less work have been reported on the design and failure analysis these batteries for practical applications. In this work, we analyzed various cell design parameters affecting the performance of pouch cells using micron-sized porous Si with nano-pore structure and coated by pitch-carbon (p-Si/C). The correlation among particle level, electrode level, and cell level properties, especially the effect of electrode density on the volumetric capacity density of Si anode and full batteries have been systematically investigated. It is found that the corrosion of p-Si/C particle surface is the main failure mechanisms on the eventual capacity loss, while Li plating on anode electrode surface is the main reason for the fast capacity loss in later stage of cycling. The volumetric capacity of Si anode highly depends on both electrode density and the Si content. Moreover, the prelithiation of Si anodes is found to increase energy density while decreasing cycle life of Si-based full cells. Finally, the pathways and strategies for adoption of micron-sized p-Si/C anodes in LIBs have been proposed for their practical applications.

25 ENERGY STORAGE↗

Develop and Connect TRISO Failure Analysis and Uncertainty Quantification to Fission Product Release Calculation Capability

The U.S. Department of Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program aims to develop predictive capabilities by applying computational methods to the analysis and design of advanced reactor and fuel cycle systems. This program has been providing engineering-scale support for the development of BISON, a high-fidelity and high-resolution fuel performance tool. Stress-based failure probability has been developed and analyzed to assess the integrity of tri-structural isotropic (TRISO) fuel particles during fuel life cycles. While simple, stress-based approaches to failure probability leveraging the Weibull statistical distribution entails a number of drawbacks when stress concentration occurs near crack tips, including finite element mesh size dependency. In this report, we use an interaction integral approach to the computation of stress intensity factors in functionally graded materials (FGM) for axisymmetric models. The inner pyrolytic carbon (IPyC) cracking induced silicon carbide (SiC) failure is one of the dominated failure modes in TRISO failure analysis. In this study, we consider a crack in the IPyC layer perpendicular to the SiC layer. The interface between these two TRISO layers is considered to be porous, which we simulate considering a transition of mechanical properties over the porous length. These aspects are considered in the computation of stress intensity factor (SIF) from a fracture mechanics approach and compared with the known stress-based failure probability approach.

42 ENGINEERING↗

Assessment of Intralaminar Progressive Damage and Failure Analysis Using an Efficient Evaluation Framework

Reducing the timeline for development and certification for composite structures has been a long standing objective of the aerospace industry. This timeline can be further exacerbated when attempting to integrate new fiber-reinforced composite materials due to the large number of testing required at every level of design. computational progressive damage and failure analysis (PDFA) attempts to mitigate this effect; however, new PDFA methods have been slow to be adopted in industry since material model evaluation techniques have not been fully defined. This study presents an efficient evaluation framework which uses a piecewise verification and validation (V&V) approach for PDFA methods. Specifically, the framework is applied to evaluate PDFA research codes within the context of intralaminar damage. Methods are incrementally taken through various V&V exercises specifically tailored to study PDFA intralaminar damage modeling capability. Finally, methods are evaluated against a defined set of success criteria to highlight successes and limitations.

Hyder, Imran↗

A Framework for Performing Multiscale Stochastic Progressive Failure Analysis of Composite Structures

A framework is presented that enables coupled multiscale analysis of composite structures. The recently developed, free, Finite Element Analysis - Micromechanics Analysis Code (FEAMAC) software couples the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) with ABAQUS to perform micromechanics based FEA such that the nonlinear composite material response at each integration point is modeled at each increment by MAC/GMC. As a result, the stochastic nature of fiber breakage in composites can be simulated through incorporation of an appropriate damage and failure model that operates within MAC/GMC on the level of the fiber. Results are presented for the progressive failure analysis of a titanium matrix composite tensile specimen that illustrate the power and utility of the framework and address the techniques needed to model the statistical nature of the problem properly. In particular, it is shown that incorporating fiber strength randomness on multiple scales improves the quality of the simulation by enabling failure at locations other than those associated with structural level stress risers.

Bednarcyk, Brett A.↗

A Framework for Performing Multiscale Stochastic Progressive Failure Analysis of Composite Structures

A framework is presented that enables coupled multiscale analysis of composite structures. The recently developed, free, Finite Element Analysis-Micromechanics Analysis Code (FEAMAC) software couples the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) with ABAQUS to perform micromechanics based FEA such that the nonlinear composite material response at each integration point is modeled at each increment by MAC/GMC. As a result, the stochastic nature of fiber breakage in composites can be simulated through incorporation of an appropriate damage and failure model that operates within MAC/GMC on the level of the fiber. Results are presented for the progressive failure analysis of a titanium matrix composite tensile specimen that illustrate the power and utility of the framework and address the techniques needed to model the statistical nature of the problem properly. In particular, it is shown that incorporating fiber strength randomness on multiple scales improves the quality of the simulation by enabling failure at locations other than those associated with structural level stress risers.

Bednarcyk, Brett A.↗

Review of the probabilistic failure analysis methodology and other probabilistic approaches for application in aerospace structural design

Probabilistic structural analyses and design methods are steadily gaining acceptance within the aerospace industry. The safety factor approach to design has long been the industry standard, and it is believed by many to be overly conservative and thus, costly. A probabilistic approach to design may offer substantial cost savings. This report summarizes several probabilistic approaches: the probabilistic failure analysis (PFA) methodology developed by Jet Propulsion Laboratory, fast probability integration (FPI) methods, the NESSUS finite element code, and response surface methods. Example problems are provided to help identify the advantages and disadvantages of each method.

Townsend, J.↗

Multiscale Failure Analysis of Laminated Composite Panels Subjected to Blast Loading Using FEAMAC/Explicit

This preliminary report demonstrates the capabilities of the recently developed software implementation that links the Generalized Method of Cells to explicit finite element analysis by extending a previous development which tied the generalized method of cells to implicit finite elements. The multiscale framework, which uses explicit finite elements at the global-scale and the generalized method of cells at the microscale is detailed. This implementation is suitable for both dynamic mechanics problems and static problems exhibiting drastic and sudden changes in material properties, which often encounter convergence issues with commercial implicit solvers. Progressive failure analysis of stiffened and un-stiffened fiber-reinforced laminates subjected to normal blast pressure loads was performed and is used to demonstrate the capabilities of this framework. The focus of this report is to document the development of the software implementation; thus, no comparison between the results of the models and experimental data is drawn. However, the validity of the results are assessed qualitatively through the observation of failure paths, stress contours, and the distribution of system energies.

Pineda, Evan J.↗

Failure Analysis Results and Corrective Actions Implemented for the Extravehicular Mobility Unit 3011 Water in the Helmet Mishap

Water entered the Extravehicular Mobility Unit (EMU) helmet during extravehicular activity (EVA) no. 23 aboard the International Space Station on July 16, 2013, resulting in the termination of the EVA approximately 1 hour after it began. It was estimated that 1.5 liters of water had migrated up the ventilation loop into the helmet, adversely impacting the astronaut's hearing, vision, and verbal communication. Subsequent on-board testing and ground-based test, tear-down, and evaluation of the affected EMU hardware components determined that the proximate cause of the mishap was blockage of all water separator drum holes with a mixture of silica and silicates. The blockages caused a failure of the water separator degassing function, which resulted in EMU cooling water spilling into the ventilation loop, migrating around the circulating fan, and ultimately pushing into the helmet. The root cause of the failure was determined to be ground-processing shortcomings of the Airlock Cooling Loop Recovery (ALCLR) Ion Filter Beds, which led to various levels of contaminants being introduced into the filters before they left the ground. Those contaminants were thereafter introduced into the EMU hardware on-orbit during ALCLR scrubbing operations. This paper summarizes the failure analysis results along with identified process, hardware, and operational corrective actions that were implemented as a result of findings from this investigation.

Steele, John↗

Failure Analysis Results and Corrective Actions Implemented for the EMU 3011 Water in the Helmet Mishap

During EVA (Extravehicular Activity) No. 23 aboard the ISS (International Space Station) on 07/16/2013 water entered the EMU (Extravehicular Mobility Unit) helmet resulting in the termination of the EVA (Extravehicular Activity) approximately 1-hour after it began. It was estimated that 1.5-L of water had migrated up the ventilation loop into the helmet, adversely impacting the astronauts hearing, vision and verbal communication. Subsequent on-board testing and ground-based TT and E (Test, Tear-down and Evaluation) of the affected EMU hardware components led to the determination that the proximate cause of the mishap was blockage of all water separator drum holes with a mixture of silica and silicates. The blockages caused a failure of the water separator function which resulted in EMU cooling water spilling into the ventilation loop, around the circulating fan, and ultimately pushing into the helmet. The root cause of the failure was determined to be ground-processing short-comings of the ALCLR (Airlock Cooling Loop Recovery) Ion Filter Beds which led to various levels of contaminants being introduced into the Filters before they left the ground. Those contaminants were thereafter introduced into the EMU hardware on-orbit during ALCLR scrubbing operations. This paper summarizes the failure analysis results along with identified process, hardware and operational corrective actions that were implemented as a result of findings from this investigation.

Steele, John↗

Testing Recommendations for Thermal Failure Analysis

Minimizing ranges of uncertainty in failure QOIs is vital for making informed engineering decisions. To improve our decision-making ability, it is necessary to have a QOI representation that captures more complex failure modes. Capturing the physics of complex time-dependent temperature failure in explicit detail can be computationally and experimentally expensive. To avoid this blooming of complication and costs, an empirical QOI component-level failure/damage model may be sufficient to help identify component-level failure. In this context, failure and damage are abstractions of more complicated processes that lead to the cessation of normal operating behavior, not a representation of mechanical damage, such as void formation. Such a model requires minimal increases in computational cost and experimental burden. The proposed QOI serves as an indicator that something has likely failed, similar to the previous critical failure temperatures or pressures. This QOI will not replace any existing failure QOIs. It will be calculated alongside them, allowing for preservation of legacy style QOI measurements with new context from the new QOI.

36 MATERIALS SCIENCE↗