Device failure analysis by scanning electron microscopy
Scanning electron microscopy for semiconductor device failure analysis
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Scanning electron microscopy for semiconductor device failure analysis
Scanning electron microscopes are used to determine both user-induced damages and manufacturing defects subtle enough to be missed by conventional light microscopy. Method offers greater depth of field and increased working distances.
X-ray nanotomography and focused ion beam scanning electron microscopy (FIB-SEM) have been applied to investigate the complex 3D microstructure of solid oxide fuel cell (SOFC) electrodes at spatial resolutions of 45 nm and below. The application of near edge differential absorption for x-ray nanotomography and energy selected backscatter detection for FIB-SEM enable elemental mapping within the microstructure. Using these methods, non-destructive 3D x-ray imaging and FIB-SEM serial sectioning have been applied to compare three-dimensional elemental mapping of the LSM, YSZ, and pore phases in the SOFC cathode microstructure. The microstructural characterization of an SOFC cathode is reported based on these measurements. The results presented demonstrate the viability of x-ray nanotomography as a quantitative characterization technique and provide key insights into the SOFC cathode microstructure.
Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.
In-situ tensile tests have been performed in a dual beam focused ion beam and scanning electron microscope on as-grown and prestrained single-crystal molybdenum-alloy (Mo-alloy) fibers. The fibers had approximately square cross sections with submicron edge lengths and gauge lengths in the range of 9–41 μm. In contrast to previously observed yield strengths near the theoretical strength of 10 GPa in compression tests of ~1–3-μm long pillars made from similar Mo-alloy single crystals, a wide scatter of yield strengths between 1 and 10 GPa was observed in the as-grown fibers tested in tension. Deformation was dominated by inhomogeneous plastic events, sometimes including the formation of Lüders bands. In contrast, highly prestrained fibers exhibited stable plastic flow, significantly lower yield strengths of ~1 GPa, and stress–strain behavior very similar to that in compression. A simple, statistical model incorporating the measured dislocation densities is developed to explain why the tension and compression results for the as-grown fibers are different.
The scanning electron microscope is becoming a popular tool to perform tasks that require positioning, manipulation, characterization, and assembly of micro-components. However, some of these applications require a higher level of performance with respect to dynamics and precision of positioning. One limiting factor is the presence of unidentified noises and disturbances. This work aims to study the influence of mechanical disturbances generated by the environment and by the microscope, identifying how these can affect elements in the vacuum chamber. To achieve this objective, a dedicated setup, including a high-resolution vibrometer, was built inside the microscope. This work led to the identification and quantification of main disturbances and noise sources acting on a scanning electron microscope. Furthermore, the effects of external acoustic excitations were analysed. Potential applications of these results include noise compensation and real-time control for high accuracy tasks.
Channel electron multipliers for cathode luminescent collection of topographic details
A scanning transmission electron microscopy (STEM) system is disclosed. The system may make use of an electron beam scanning system configured to generate a plurality of electron beam scans over substantially an entire sample, with each scan varying in electron-illumination intensity over a course of the scan. A signal acquisition system may be used for obtaining at least one of an image, a diffraction pattern, or a spectrum from the scans, the image, diffraction pattern, or spectrum representing only information from at least one of a select subplurality or linear combination of all pixel locations comprising the image. A dataset may be produced from the information. A subsystem may be used for mathematically analyzing the dataset to predict actual information that would have been produced by each pixel location of the image.
Not provided.
Scanning electron microscope images obtained on a cross-section of a sputtered multilayer structure have proven to be crucial for qualifying these films for their intended use as a multilayer Laue lens. The quality of the linear Fresnel zone structure is assessed by means of image processing and analyses, and these analyses are then used to qualify the structure for further lens processing. The image analysis as well as problematic SEM artifacts are discussed.
Introduction: Scanning electron microscopy (SEM) in concert with element identification by energy dispersive Xray (EDX) spectroscopy has become an indispensable tool in the analyses of extraterrestrial materials. Nevertheless, to-date, SEM-EDX instrumentation has remained purely in the purview of terrestrial laboratories due to their size, complexity, and operational requirements. However, in January 2022 a miniaturized SEM-EDX called MOCHII became the first successful space-based instrument of its kind, following its deployment onboard the International Space Station (ISS). It represents the culmination of nearly 40 years of technological development. We have performed an on-orbit study with MOCHII with the goal of evaluating its potential as the progenitor of a new generation of spacecraftbased instruments for use in future manned and robotic planetary exploration missions. Out goal has been to validate the on-orbit investigation of samples relevant to astromaterials and astrobiology. We have performed in-situ analyses on standards and a freshly fractured fragment of the Martian meteorite Allan Hills 84001 which was first analyzed, prior to launch, using an engineering MOCHII ground unit located at Johnson Space Center in Houston. Results of both imaging and compositional analyses substantiates the utility of remote SEM-EDX analyses in low Earth orbit (LEO).
Environmental Scanning Electron Microscopy (ESEM) is used to study the origin of micro-crack healing in an Engineered Cementitious Composite (ECC). ESEM images were acquired from ECC specimens cut from pre-cracked, dog-bone samples which then subjected to submerged curing followed by exposure to the natural environment. The mineralogical and chemical compositions of the healing products were determined using the EDX facility in the ESEM. It is shown that the precipitation of calcium carbonate is the main contributor to micro-crack healing at the crack mouth. The healing products initially appeared in an angular rhombohedral morphology which then underwent a discernable transformation in size, shape and surface texture, from relatively flat and smooth to irregular and rough, resembling the texture of the original surface areas surrounding the micro-cracks. It is also shown that exposure to the natural environment, involving intermittent wetting/drying cycles, promotes additional crystal growth, which indicates enhanced self-healing capability in this environment. - Highlights: •ESEM with EDX used to characterize the origin of micro-crack healing in an ECC •Evolution of healing precipitates studied at three specific locations over four weeks •Specimens exposed to laboratory environment, followed by the natural environment •Calcium carbonate is the main contributor to crack healing at the crack mouth. •Outdoor exposure involving intermittent rain promotes additional crystal growth.
Nonplanar field emission from electrochemically etched tungsten field emitters has been observed using near field emission scanning electron microscopy. Close-proximity field emission in adequate ultrahigh vacuum conditions was implemented to attain Fowler-Nordheim plots using typical imaging parameters. The emission radii deduced via a detailed, spherical surface field emission theory, by [Edgcombe and de Jonge, J. Phys. D 40, 4123 (2007)], reveal that our sharpest tip asperities are less than a nanometer. This yields a spatial resolution on the order of one nanometer.
Superhydrophobic surfaces (SHSs) show promise as promoters of dropwise condensation. Droplets with diameters below {approx}10 {mu}m account for the majority of the heat transferred during dropwise condensation but their growth dynamics on SHS have not been systematically studied. Due to the complex topography of the surface environmental scanning electron microscopy is the preferred method for observing the growth dynamics of droplets in this size regime. By studying electron beam heating effects on condensed water droplets we establish a magnification limit below which the heating effects are negligible and use this insight to study the mechanism of individual drop growth.
Scanning electron mirrors microscope design and development
Scanning electron microscopy (SEM) is ubiquitous for imaging but is not generally regarded as a tool for thermal measurements. Here, the temperature dependence of secondary electron (SE) emission from a sample's surface is investigated. Spatially uniform SEM images and the net charge flowing through a sample were recorded at different temperatures to quantify the temperature dependence of SE emission and electron absorption. The measurements also demonstrated charge conservation during thermal cycling by placing the sample inside a Faraday cup to capture the emitted SEs and back-scattered electrons from the sample. The temperature dependence of SE emission was measured for four semiconducting materials (Si, GaP, InP, and GaAs) with response coefficients found to be of magnitudes ~100-1000 ppm/K. The detection limits for temperature changes were no more than ±8 °C for 60 s acquisition time.
Field emission scanning electron microscopy (FESEM) is a powerful tool for analyzing surface structures of biological and nonbiological samples. However, when it is used to study fine structures of nanometer-sized microfibrils of epidermal cell walls, one often encounters tremendous challenges to acquire clear and undistorted images because of two major issues: (1) Preparation of samples suitable for high resolution imaging; due to the delicateness of some plant materials, such as onion epidermal cell walls, many things can happen during sample processing, which subsequently result in damaged samples or introduce artifacts. (2) Difficulties to acquire clear images of samples which are electron-beam sensitive and prone to charging artifacts at magnifications over 100,000×. In this chapter we described detailed procedures for sample preparation and conditions for high-resolution FESEM imaging of onion epidermal cell walls. Lastly, the methods can be readily adapted for other wall materials.