Engineering Papers⌕ Search

Engineering topics

Das, H.

Publications and source records attributed to Das, H..

At least 19 records

Magnetic Core/Shell Nanocomposites MgFe{sub 2}O{sub 4}/SiO{sub 2} for Biomedical Application: Synthesis and Properties

Magnetic core/shell (CS) nanocomposites (MNCs) are synthesized using a simple method, in which a magnesium ferrite nanoparticle (MgFe{sub 2}O{sub 4}) is a core, and an amorphous silicon dioxide (silica SiO{sub 2}) layer is a shell. The composition, morphology, and structure of synthesized particles are studied using X-ray diffraction, field emission electron microscopy, transmission electron microscopy (TEM), energy-dispersive spectroscopy (EDS), scattering electrophoretic photometer, thermogravimetric analysis (TGA), and Mössbauer spectroscopy. It is found that the MgFe{sub 2}O{sub 4}/SiO{sub 2} MNC has the core/shell structure formed by the Fe‒O–Si chemical bond. After coating with silica, the MgFe{sub 2}O{sub 4}/SiO{sub 2} MNC saturation magnetization significantly decreases in comparison with MgFe{sub 2}O{sub 4} particles without a SiO{sub 2} shell. Spherical particles agglomerated from MgFe{sub 2}O{sub 4} nanocrystallites ∼9.6 and ∼11.5 nm in size function as cores coated with SiO{sub 2} shells ∼30 and ∼50 nm thick, respectively. The total size of obtained CS MNCs is ∼200 and 300 nm, respectively. Synthesized CS MgFe{sub 2}O{sub 4}/SiO{sub 2} MNCs are very promising for biomedical applications, due to the biological compatibility of silicon dioxide, its sizes, and the fact that the Curie temperature is in the region required for hyperthermal therapy, 320 K.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Bainitic Microstructure on Ballistic Performance of Armour Steel Weld Metal Using Developed High Ni-Coated Electrode

Welding of armour steel has gained significant importance during the past few years as recent civilian and military requirements demand weld metal properties matching with base metal having good ballistic performance along with high strength and toughness at − 40 °C as per specification. The challenge of armour steel welding therefore lies in controlling the weld metal composition which is strongly dependent on welding electrode/consumables, resulting in desired weld microstructure consisting of lower bainite along with retained austenite. The performance of butt-welded armour steel joints produced by the developed electrodes was evaluated using tensile testing, ballistic testing, impact toughness at room temperature and subzero temperature. Microstructures of weld metals are exclusively characterized by x-ray diffraction technique, scanning electron microscope and transmission electron microscopy with selected area diffraction pattern. Experimental results show that weld metal with relatively lower carbon, higher manganese and lower nickel content was attributed to lower bainite with film type of retained austenite may be considered as a most covetable microstructure for armour steel weld metal.

36 MATERIALS SCIENCE↗

RoboPol: first season rotations of optical polarization plane in blazars

Here, we present first results on polarization swings in optical emission of blazars obtained by RoboPol, a monitoring programme of an unbiased sample of gamma-ray bright blazars specially designed for effective detection of such events. A possible connection of polarization swing events with periods of high activity in gamma-rays is investigated using the data set obtained during the first season of operation. It was found that the brightest gamma-ray flares tend to be located closer in time to rotation events, which may be an indication of two separate mechanisms responsible for the rotations. Blazars with detected rotations during non-rotating periods have significantly larger amplitude and faster variations of polarization angle than blazars without rotations. Our simulations show that the full set of observed rotations is not a likely outcome (probability ≤1.5 × 10 -2 ) of a random walk of the polarization vector simulated by a multicell model. Furthermore, it is highly unlikely (~5 × 10 -5 ) that none of our rotations is physically connected with an increase in gamma-ray activity.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct band gaps in multiferroic h-LuFeO{sub 3}

We measured the optical properties of epitaxial thin films of the metastable hexagonal polymorph of LuFeO{sub 3} by absorption spectroscopy, magnetic circular dichroism, and photoconductivity. Comparison with complementary electronic structure calculations reveals a 1.1 eV direct gap involving hybridized Fe 3d{sub z{sup 2}}+O 2p{sub z}→Fe d excitations at the Γ and A points, with a higher energy direct gap at 2.0 eV. Both charge gaps nicely overlap the solar spectrum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pharmacotherapeutics of Intranasal Scopolamine: FDA Regulations and Procedures for Clinical Applications

Space Motion Sickness (SMS) is commonly experienced by astronauts and often requires treatment with medications during the early flight days of a space mission. Bioavailability of oral (PO) SMS medications is often low and highly variable; additionally, physiological changes in a microgravity environment exacerbate variability and decrease bioavailability. These factors prompted NASA to develop an intranasal dosage form of scopolamine (INSCOP) suitable for the treatment of SMS. However, to assure safety and efficacy of treatment in space, NASA physicians prescribe commercially available pharmaceutical products only. Development of a pharmaceutical preparation for clinical use must follow distinct clinical phases of testing, phase I through IV to be exact, before it can be approved by the FDA for approval for clinical use. After a physician sponsored Investigative New Drug (IND) application was approved by the FDA, a phase I clinical trial of INSCOP formulation was completed in normal human subjects and results published. The current project includes three phase II clinical protocols for the assessment of pharmacokinetics and pharmacodynamics (PK/PD), efficacy, and safety of INSCOP. Three clinical protocols that were submitted to FDA to accomplish the project objectives: 1) 002-A, a FDA Phase II dose ranging study with four dose levels between 0.1 and 0.4 mg in 12 subjects to assess PK/PD, 2) 002-B, a phase II clinical efficacy study in eighteen healthy subjects to compare efficacy of 0.2 (low dose) and 0.4 mg (high dose) INSCOP for prophylactic treatment of motion-induces (off-axis vertical rotation) symptoms, and (3) 002-C, a phase II clinical study with twelve subjects to determine bioavailability and pharmacodynamics of two doses (0.2 and 0.4 mg) of INSCOP in simulated microgravity, antiorthostatic bedrest. All regulatory procedures were competed that include certification for Good laboratory Procedures by Theradex , clinical documentation, personnel training, selection of clinical research operations contractor, data capturing and management, and annual reporting of results to FDA were successfully completed. Protocol 002-A was completed and sample and data analysis is currently in progress. Protocol 002-B is currently in progress at Dartmouth Hitchcock Medical Center and Protocol 002-C has been submitted to the FDA and will be implemented at the same contractor site as 002-A. An annual report was filed as required by FDA on the results of Protocol 002-A. Once all the three Phase II protocols are completed, a New Drug Administration application will be filed with FDA for Phase III clinical assessment and approval for marketing of the formulation. A commercial vendor will be identified for this phase. This is critical for making this available for treatment of SMS in astronauts and military personnel on duty. Once approved by FDA, INSCOP can be also used by civilian population for motion sickness associated with recreational travel and other ailments that require treatment with anticholinergic drugs.

Das, H.↗

Pharmacodynamics of Promethazine in Human Subjects

Promethazine (PMZ) is the drug of choice for the treatment of symptoms associated with space motion sickness in astronauts. Side effects of PMZ include sedation, dizziness and cognitive performance impairment. In this study, we examined pharmacodynamics (PD) in human subjects and validated methods for evaluating cognitive performance effects of medications in space. METHODS: PMZ (12.5,25, and 50 mg) or placebo was administered by IM injection to human subjects in a randomized double-blind treatment design. Samples and data were collected for 72 h post dose. PD evaluation was performed using a battery of performance tests administered using WinSCAT (Windows based Space Cognitive Assessment Test) on a laptop computer, and ARES (ANAM Readiness Evaluation System) on a PDA, plasma concentrations of PMZ were measured using a LC-MS method. RESULTS: Results indicate a linear correlation between PMZ concentration and cognitive performance parameters (p<0.01). Test accuracy decreased and test completion time and response time increased significantly with increasing plasma PMZ concentration. CONCLUSIONS: These results suggest a concentration dependent decrement in cognitive performance associated with PMZ. WinSCAT and ARES are sensitive tools for the assessment PMZ PD and may be applicable for such evaluations with other neurocognitive drugs.

Gatlin, K. T.↗

The CLARAty architecture for robotic autonomy

This paper presents an overview of a newly developed Coupled Layer Architecture for Robotic Autonomy (CLARAty), which is designed for improving the modularity of system software while more tightly coupling the interaction of autonomy and controls.

robotics autonomy architecture software Mars↗

Ultrasonic Motors (USM) - an emerging actuation technology for planetary applications

A hybrid model that addressed a complete ultrasonic motor as a system was developed. The model allows using powerful commercial FE package to express dynamic characteristics of the stator and the rotor in engineering practice. An analog model couples the finite element models for the stator and rotor for the stator-interface layer-rotor syste. The model provides reasonably accurate results for CAD.

electroactive polymers actuators EAP materials art↗

Autonomous Vision-Based Manipulation from a Rover Platform

Current rover designs use on-board manipulators to enhance their capabilities for planetary exploration and in-situ science. In this paper, we describe how these manipulators can be used to perform two types of operations: rock sample aquisition for return to earth and instrument placement for in-situ science meausrements.

autonomous manipulation rock acquisition instrumen↗

An Integrated Architecture for Cooperation Rovers

The paper presents a rover execution architecture for controlling multiple, cooperating rovers. The overall goal of this architecture is to coordinate multiple rovers in performing complex tasks for planetary science.

multi-rover↗

Autonomous Rover Technology for Mars Sample Return

This paper summarizes a series of experimental results in the evaluation and demonstration of planetary rover autonomy, with a particular emphasis on rover system technology capabilities under development for a 2005 Mars sample return mission and its precursor missions.

rovers↗

Robot Manipulator Technologies for Planetary Exploration

NASA exploration missions to Mars, initiated by the Mars Pathfinder mission in July 1997, will continue over the next decade. The missions require challenging innovations in robot design and improvements in autonomy to meet ambitious objectives under tight budget and time constraints. The authors are developing design tools, component technologies and capabilities to address these needs for manipulation with robots for planetary exploration. The specific developments are: 1) a software analysis tool to reduce robot design iteration cycles and optimize on design solutions, 2) new piezoelectric ultrasonic motors (USM) for light-weight and high torque actuation in planetary environments, 3) use of advanced materials and structures for strong and light-weight robot arms and 4) intelligent camera-image coordinated autonomous control of robot arms for instrument placement and sample acquisition from a rover vehicle.

Das, H.↗