FY26 Efforts to Revive and Update the ANS-54.8 Liquid Metal Fire Protection Standard
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The purpose of this project is to design the demolition and installation of a deluge valve swap from a DV-5 to a DV-5A valve.
Solid polymer electrolytes based on plastic crystals are promising for solid-state sodium metal (Na 0 ) batteries, yet their practicality has been hindered by the notorious Na 0 -electrolyte interface instability issue, the underlying cause of which remains poorly understood. Here, in this study, by leveraging a model plasticized polymer electrolyte based on conventional succinonitrile plastic crystals, we uncover its failure origin in Na 0 batteries is associated with the formation of a thick and non-uniform solid electrolyte interphase (SEI) and whiskery Na 0 nucleation/growth. Furthermore, we design a new additive-embedded plasticized polymer electrolyte to manipulate the Na 0 deposition and SEI formulation. For the first time, we demonstrate that introducing fluoroethylene carbonate (FEC) additive into the succinonitrile-plasticized polymer electrolyte can effectively protect Na 0 against interfacial corrosion by facilitating the growth of dome-like Na 0 with thin, amorphous, and fluorine-rich SEIs, thus enabling significantly improved performances of Na//Na symmetric cells (1,800 h at 0.5 mA cm −2 ) and Na//Na 3 V 2 (PO 4 ) 3 full cells (93.0 % capacity retention after 1,200 cycles at 1 C rate in coin cells and 93.1 % capacity retention after 250 cycles at C/3 in pouch cells at room temperature). Our work provides valuable insights into the interfacial failure of plasticized polymer electrolytes and offers a promising solution to resolving the interfacial instability issue.
In some crewed-spacecraft applications, onboard materials are intentionally selected to function as hazard control barriers to prevent powered hardware and/or ignited flammable items from igniting nearby flammable materials by acting as non-breaching, non-flammable containment (e.g., cargo transfer bags, zero gravity stowage racks, and jettison stowage bags on the International Space Station). Historically, flammability self-extinguishment testing of broad acreage or outermost layer materials alone was believed to be sufficient to verify overall flammability compliance. Though required, testing on design features such as threaded seams and zippers was not performed due to the incorrect assumption that flammability performance would not be impacted. However, recent coupon level testing of layups and configurations consisting of multiple materials have revealed that these features may be more susceptible to ignition and fire propagation than the bulk material. Additionally, configurational coupon ignition and propagation testing does not explicitly determine a material’s ability to provide protection to vulnerable flammable hardware. The need to evaluate this gap in assessing material or layup effectiveness as fire barriers between ignition sources and flammable materials led to the development of a new configuration-based fire barrier test. Test setup, relevant configurations, and test validation are discussed. The new barrier test method establishes a configuration for the test apparatus, identifies a conservative ignitor configuration, and defines pass/fail criteria. Test setup, relevant configurations, and test validation are discussed.
Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A method of making thin films of sodium fluorides and their derivatives by atomic layer deposition (“ALD”). A sodium precursor is exposed to a substrate in an ALD reactor. The sodium precursor is purged, leaving the substrate with a sodium intermediate bound thereon. A fluorine precursor is exposed to the bound sodium intermediate in the ALD reactor. The fluorine precursor is purged and a sodium fluoride film is formed on the substrate.
Explore the source record for details and available documents.
Proceedings of conference on materials for improved fire safety with application to design and development of spacecraft and support equipment
The Ford Motor Company published papers describing new types of secondary battery comprised of: solid, sodium ion conducting electrolyte; liquid metal electrode; redox electrode; operating temperature between 300 and 400 deg. C; specific energy of 150 Wh/kg; and a nominal voltage of 2.0 V.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present preliminary results on the development of a fire detection system for partial and low gravity environments. A significant challenge is the design of a system with a low false alarm rate. The detection system therefore has to discriminate between combustion particles, cabin, and lunar dust. Aerosol properties are measured and cross referenced to the target detectors at the Gases and Aerosols from Smoldering Polymers (GASP) Laboratory located at the NASA Glenn Research Center. A computational fluid dynamics plume model is also employed to determine the smoke transport properties of the targeted habitats.
Not provided.
Solid-state amine absorbent materials, including those containing guanidine derivatives, have received tremendous attention as the world combats the challenges of climate change.
Explore the source record for details and available documents.