Flammability Test Method for Materials Intended for Use as Fire Barriers in Crewed Habitats

Abstract

In some crewed-spacecraft applications, onboard materials are intentionally selected to function as hazard control barriers to prevent powered hardware and/or ignited flammable items from igniting nearby flammable materials by acting as non-breaching, non-flammable containment (e.g., cargo transfer bags, zero gravity stowage racks, and jettison stowage bags on the International Space Station). Historically, flammability self-extinguishment testing of broad acreage or outermost layer materials alone was believed to be sufficient to verify overall flammability compliance. Though required, testing on design features such as threaded seams and zippers was not performed due to the incorrect assumption that flammability performance would not be impacted. However, recent coupon level testing of layups and configurations consisting of multiple materials have revealed that these features may be more susceptible to ignition and fire propagation than the bulk material. Additionally, configurational coupon ignition and propagation testing does not explicitly determine a material’s ability to provide protection to vulnerable flammable hardware. The need to evaluate this gap in assessing material or layup effectiveness as fire barriers between ignition sources and flammable materials led to the development of a new configuration-based fire barrier test. Test setup, relevant configurations, and test validation are discussed. The new barrier test method establishes a configuration for the test apparatus, identifies a conservative ignitor configuration, and defines pass/fail criteria. Test setup, relevant configurations, and test validation are discussed.

Keep this discovery

BibTeXRIS

Susana Harper, Stephen Peralta, Patrick Simpkins, Morgan B Abney, Sara Wilson, Alfredo Juarez, Emily Hacopian, Stephen Herald. Flammability Test Method for Materials Intended for Use as Fire Barriers in Crewed Habitats. https://ntrs.nasa.gov/citations/20260003508

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Flammability Testing Configuration and Approach of Barrier Material Assemblies Designed for Space Flight Applications

The NASA Engineering and Safety Center (NESC) partnered with Materials and Processes and Flammability subject matter experts from the Johnson Space Center, White Sands Test Facility, and the Marshall Space Flight Center to design and develop a test for evaluating the effectiveness of material assemblies to serve as a barrier between a potential cabin ignition source based on typical flammable materials in the habitable volume of spacecraft.

Morgan Abney

Risks of Depress as a Fire Suppression Technique in Spacecraft

Spacecraft are designed to prevent fires through careful material selection and configuration control combined with electrical design controls and isolation of ignition sources. Despite these best efforts, fire risk still exists due to the potential for configuration changes with the introduction of crew and the potential for a ‘failure of imagination’ by designers in anticipating all fuel and ignition sources. Therefore, fire suppression is a critical capability for any crewed spacecraft as a last resort for crew survival. Many spacecraft suppression methods have relied on fire suppressants such as compressed carbon dioxide, nitrogen, and water. A proposed alternative is depressurization of the cabin as a method to extinguish a fire. Limited testing was conducted during Skylab and showed that depress could result in stirring the air flow and aggravating a fire before extinguishing. However, limited information was available on how the test was conducted. To better characterize the approach, testing was conducted at NASA’s White Sands Test Facility to evaluate the effect of depressurization on material extinguishment. The results showed that depressurization does not provide a safe and effective fire suppression capability. The testing approach, results, and conclusions are described and discussed.

Toni Griego