Engineering PapersSearch

SEARCH · Engineering Papers

Results for “High resolution spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES

CH3OH and HCN in Interstellar Comet 3I/ATLAS Mapped with the ALMA Atacama Compact Array: Distinct Outgassing Behaviors and a Remarkably High CH3OH/HCN Production Rate Ratio

We report the detection of methanol (CH3OH) toward interstellar comet 3I/ATLAS using the At-acama Compact Array of the Atacama Large Millimeter/Submillimeter Array (ALMA) on UT 2025 August 28, September 18 and 22, and October 1, and of hydrogen cyanide (HCN) on September 12 and 15. These observations spanned pre-perihelion heliocentric distances (r H ) of 2.6 – 1.7 au. The molecules showed outgassing patterns distinct from one another, with HCN production being depleted in the sunward hemisphere of the coma, whereas CH3OH was enhanced in that direction. Statistical analysis of molecular scale lengths in 3I/ATLAS indicated that CH3OH included production from coma sources at Lp > 258 km at 99% confidence. However low signal-to-noise on long baselines, which sample emission on small spatial scales closest to the nucleus, prevented definitively ruling out CH3OH as purely a parent species. In contrast, HCN production was indistinguishable from direct nucleus sublimation. The CH3OH production rate increased sharply from August through October, including an uptick near the inner edge of the H2O sublimation zone at rH = 2 au. Compared to comets measured to date at radio wavelengths, the derived CH3OH/HCN ratios in 3I/ATLAS of 124+30−34 and 79+11−14on September 12 and 15, respectively, are among the most enriched values measured in any comet, surpassed only by anomalous solar system comet C/2016 R2 (PanSTARRS)

Comae

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Detecting Magnon-phonon coupling in yttrium iron garnet with variable temperature STEM-EELS

Magnons, quanta of spin wave excitations in magnetically ordered materials, have been identified as candidates for several potentially transformative technologies in recent years. Macroscopic techniques, such as neutron scattering or Raman spectroscopy, can be used to identify and analyze magnons, but provide relatively delocalized information about the sample. Understanding how the bonding and local structure of a material interacts with, and influences, the magnon population in a material is a crucial step toward the ability to produce any real-world application utilizing magnons. By leveraging the combined spatial resolution of scanning transmission electron microscopy (STEM) and the energy resolution of monochromated electron energy-loss spectroscopy (EELS) nanoscale analysis of magnons can be performed. While the weak interaction of magnons with the electron beam makes magnon EELS challenging on reasonable timescales, magnon-phonon coupling can be leveraged to understand magnons through their effect on the more easily measured phonons. Here, we examine yttrium iron garnet (YIG) flakes, and demonstrate non-linear, temperature-dependent shifts in the phonon frequencies, consistent with previously described magnon-phonon coupling effects. The ability to measure the temperature-dependence of vibrational frequencies with high precision in individual nanoscale flakes, demonstrates the ability to study magnon-phonon coupling in the STEM with unprecedented spatial resolution.

Reifsnyder, Alexander [ORNL]

Uncovering the linear boron environment in Na 3 BP 2 through solid-state 11 B NMR spectroscopy

Boron-based compounds exhibit a wide range of structural diversity, with potential applications spanning organic and inorganic chemistry. Herein, we focus on the characterization of the linear boron-phosphorus unit P═B═P in Na 3 BP 2 using solid-state nuclear magnetic resonance (ssNMR) spectroscopy and density functional theory (DFT) calculations. High-resolution 11 B ssNMR spectra were recorded at two fields, and key parameters such as chemical shift anisotropy (CSA), quadrupolar coupling constants (C Q ), and electric field gradient (EFG) tensors were extracted. The 11 B NMR results revealed a distinct chemical environment for the two-coordinate boron atom, with a CSA span (Ω) of 280 ppm and a C Q of 3.0 MHz. These values were further validated through periodic plane-wave DFT calculations, which showed good agreement with experimental results. The obtained spectral parameters are compared to other linear boron units, such as the BO 2 motif, providing a broader context for understanding boron coordination in inorganic compounds. This work expands the body of NMR knowledge on boron-containing materials, particularly for linear boron motifs. The findings contribute to the growing field of boron chemistry and its potential applications in advanced materials.

Porter, Andrew P. [Ames Laboratory (AMES), Ames, I

Fingerprinting Uranium Oxides with Electron Energy Loss Spectroscopy Supported by Theoretical Computations

Uranium oxides occur in a variety of phases that differ in crystal structure and uranium oxidation states. Electron energy loss spectroscopy (EELS) is one of the few techniques that has sufficient spatial resolution and sensitivity to electronic structure to distinguish amongst phases at the nanoscale. However, beam-sensitive materials such as uranium oxides are subject to spectral modification due to interactions with the electron beam. Therefore, theory support is essential to reliably exclude the impact of beam damage and generate true reference datasets. Here we use a comparison of theoretical and experimental spectra to probe the impact of beam damage on O K-edge and U N-edge (N6,7 and N4,5) EELS spectra of various single-valent and mixed-valence uranium oxide bulk phases. Using a low-dose experimental set-up, we show that the O K-edge theoretical spectra are in excellent agreement with experiment for both peak positions and relative intensities of respective peaks. In contrast, U N-edge features are less distinguishing due to the partially localized nature of the U 5f orbitals and overlapping multiplet and spin–orbit coupling effects. This work demonstrates that O K-edge EELS is sufficiently diagnostic to distinguish a wide range of uranium oxides and that the experimental approach used here minimizes beam damage and allows valence state discrimination across the U(IV), U(V) and U(VI) series. When combined with imaging modes available in electron mi-croscopy, the work enables detailed investigation and characterization of uranium redox transformations at the nanoscale.

Carbone, Jacopo

High-Resolution Global Ocean Simulation in the SWOT ERA: Introducing ECCO Llc4320v2

The Surface Water and Ocean Topography (SWOT) mission is opening up new opportunities to evaluate and drive improvement in km-scale global ocean and atmosphere-ocean models via its simultaneous swath observations of sea-surface height, wind speed, and significant wave height down to 2 km scales globally. Motivated by this, we have initiated a collaborative effort at NASA Ames to run a new global ocean-sea-ice simulation in MITgcm at a nominal 1/48-deg resolution of the year 2023 that enables direct comparisons with SWOT observations. New features relative to a prior simulation at a similar resolution of the year 2012 include much more realistic tidal forcing, thermodynamic coupling in ice-shelf cavities, high-frequency hourly atmospheric forcing, much improved river runoff, double the vertical resolution in the deep ocean (173 vs 90 levels), updated bathymetry including improvements in finescale bathymetry derived from SWOT, and updated vertical mixing scheme parameters that improve the equatorial Pacific circulation.

ECCO

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi

Passive Remote Sensing of Stratospheric and Mesospheric Winds

A passive infrared sensor is described for remote sounding of the wind field in the stratosphere and mesosphere from near Earth orbital spacecraft. The instrument uses gas correlation spectroscopy together with electro-optic phase modulation techniques to measure winds in the 20- to 120-km altitude range globally, both in the day and at night, and with a vertical resolution of better than the atmospheric scale height. Measurement of temperature and the amounts of key atmospheric species may also be made simultaneously and in coincident fields of view with the wind observations. The sensor is currently being developed at the Jet Propulsion Laboratory as a candidate for the upcoming NASA Earth Observation System.

Daniel J Mccleese

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences

First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF

This work details the construction and first in operando transient grating spectroscopy measurements conducted on PISCES-RF during plasma operation. A preliminary study on a tungsten sample with varied plasma species (Ar and D 2 ), ion flux (4 × 10 21 to 6 × 10 22 ion/m 2 /s), ion energy (5 to 80 eV), and surface temperature (20 to 200 °C) is presented. Prior to plasma exposure, the thermal diffusivity and surface acoustic wave (SAW) speed, (6.9 ± 0.2) × 10 −5 m 2 /s and (2.66 ± 0.02) km/s, were measured in situ with a thermal grating period of 12.5 μm. During Ar plasma exposure, these two quantities vary according to the sample surface temperature. At low flux and varied ion energy, D 2 plasma exposure also results in thermal diffusivity and SAW speed varying with surface temperature alone. At high flux, D 2 plasma exposure results in no convincing change to the thermal diffusivity, but the SAW speed is reduced. After returning to 20 °C, post plasma exposures, the thermal diffusivity and SAW speed almost recover to the initial value prior to exposure.

Surface acoustic wave SAW