Sensitivity of Tropical Anvils to Ice Aggregation
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
There is a growing body of theoretical and experimental evidence suggesting that the uniformity, rate, adhesion, quality, and other key properties of Chemical Vapor Deposition (CVD) diamond coatings are influenced by the gas mixing kinetics in the thermal plasma environment of the reaction chamber. The implementation of, for example, Microwave Plasma Enhanced Chemical Vapor Deposition (MPECVD) process in microgravity has, thus, been suggested. Such a diamond deposition system, which overcomes the limitations of present systems and which is distiguishable from them by the use of high pressure MPECVD and recirculation of the would be effluent hydrogen and carbon, is described. Given the key fact that there is nothing in the effluent of the MPECVD process that is truly a byproduct or 'waste', the system can, at least in principle, lend itself to being closed loop yet dynamic. The exhaust contains hydrogen and carbon species which can be recirculated to the plasma reactor, that is, since there are no unusable reaction byproducts, the effluent can be fed back to the reaction chamber with no detriment, thus allowing deployment in a microgravity environment.
Infrared-blocking, aerogel-based scattering filters have a broad range of potential applications in astrophysics and planetary science instruments in the far-infrared, sub-millimeter, and microwave regimes. This paper demonstrates the ability of conductively-loaded, polyimide aerogel filters to meet the mechanical and science instrument requirements for several experiments, including the Cosmology Large Angular Scale Surveyor (CLASS), the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), and the Sub-millimeter Solar Observation Lunar Volatiles Experiment (SSOLVE). Thermal multi-physics simulations of the filters predict their performance when integrated into a cryogenic receiver. Prototype filters have survived cryogenic cycling to 4 K with no degradation in mechanical properties. Measurement of total hemispherical reflectance and transmittance, as well as cryogenic tests of the aerogel filters in a full receiver context, allow estimates of the integrated infrared emissivity of the filters. Knowledge of the emissivity will help instrument designers incorporate the filters into future experiments in planetary science, astrophysics, and cosmology.
The objective of the Phillips Laboratory (PL) Long Duration Exposure Facility (LDEF) experiment is to determine the adverse effects of the natural space environment on laser optical component and coating materials. The LDEF experiment provides a unique opportunity for the study of optical material response to an extended low earth orbit space exposure. The PL samples consist of 10 sets of the six materials each. The materials are uncoated fused silica, magnesium fluoride coated fused silica, uncoated molybdenum, molybdenum coated with chromium, silver and thorium fluoride, diamond turned copper, and diamond turned nickel plated copper. Performance degradation will be correlated to establish trends between sample location, duration of exposure, atomic oxygen exposure and other space environmental conditions. This paper discusses the results of the tests thus far performed on the LDEF samples and the plans for the future.
Explore the source record for details and available documents.
Biosatellite fuel cell/battery power system
Explore the source record for details and available documents.
A battery cell balancing system is operable to utilize a relatively small number of transformers interconnected with a battery having a plurality of battery cells to selectively charge the battery cells. Windings of the transformers are simultaneously driven with a plurality of waveforms whereupon selected battery cells or groups of cells are selected and charged. A transformer drive circuit is operable to selectively vary the waveforms to thereby vary a weighted voltage associated with each of the battery cells.
Thin coating of high-temperature epoxy resin provides necessary electrical insulation, as well as good thermal conductivity between battery cells. Insulation increases efficiency of nickel-cadmium battery, as it would any multicell battery assembly in which cell-to-cell thermal balance is critical.
Test of electrochemical cell and local action mechanisms of wet cell battery for space probe applications
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Topics considered include: Battery design, cell design, the 'VHS' type design, positive and negative electrodes, separator, electrolite, life test, performance test, accelerated cycle test.
The objective of the research covered by this viewgraph presentation is to understand the thermal characteristics of a cylindrical aerospace battery cell by studying the surface thermal properties. The batteries tested include a nickel hydrogen cell (NiH2), and a lithium-ion cell (Li-ion).
The Power Systems Department of Eagle-Picher Industries, Inc., located in Colorado Springs, Colorado, had developed a long-life advanced Nickel-Cadmium battery cell for aerospace applications. This battery cell, known as the MAGNUM NiCd cell, offers significant life expectancy increase over traditional NiCd battery cells. In addition, it offers significant cost reduction from the Super NiCd battery cell (developed by Hughes Aircraft Company and manufactured by the Power Systems Department of Eagle-Picher Industries, Inc.).
A document discusses the use of saturating transformers in a matrix arrangement to address individual cells in a high voltage battery. This arrangement is able to monitor and charge individual cells while limiting the complexity of circuitry in the battery. The arrangement has inherent galvanic isolation, low cell leakage currents, and allows a single bad cell in a battery of several hundred cells to be easily spotted.
Percent recharge unit permits each cell of a rechargeable battery to be charged to a preset capacity of the cell. The unit automatically monitors and controls a rechargeable battery subjected to charge-discharge cycling tests.
Explore the source record for details and available documents.