Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Transistor step stress program for JANTX2N2432A

Power/temperature step stress was applied to the transistor JANTX2N2432A manufactured by Crystalonics and Texas Instruments. A total of 48 samples from each manufacturer were submitted to the process outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point.

Source record↗

Diode step stress program for JANTX1N5552

The effect of power/temperature step stress when applied to the switching diode JANTX1N5554 manufactured by Semtech and Micro Semiconductor was evaluated. A total of 48 samples from each manufacturer were submitted to the process outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Diode step stress program for JANTX1N645-1

The diode JANTX1N645-1 manufactured by Semtech and Micro Semiconductor was subjected to power/temperature step stress in order to assess its reliability. All test samples were subjected to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented in tabular form.

Source record↗

Transistor step stress program for JANTX2N2219A

Power/temperature step stress was applied to the dual transistor JANTX2N2219A manufactured by Texas Instruments and National Semiconductor. A total of 48 samples from each manufacturer were submitted to the process outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to electrical tests after completing the prior power/temperature step stress point.

Source record↗

Diode step stress testing program for JANTX1n5420

Data compiled for the purpose of evaluating the effect of power/temperature step stress when applied to the diode JANTX1N5420 manufactured by Unitrode and Micro-Semiconductor is presented. A total of 48 samples from each manufacturer was submitted to the processes outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

2019 ARIA Proposal Final Report Public Abstract: What Happens to Life in an Ocean World Plume?

The NASA Cassini mission to Saturn discovered persistent jets of water being ejected into space from a subsurface ocean on the small moon Enceladus and evidence that this ocean is habitable for life. The ice resulting from these plumes forms the E Ring of Saturn. Missions are under study to fly through these plumes and collect and analyze samples to look for evidence of life. To support design and instrument selection for these missions, there is a critical need to understand what happens to microbial life adapted to a liquid environment when suddenly ejected into the vacuum of space. We experimentally determined the structural changes in microbial cells in liquid medium when ejected into vacuum. We first developed a vacuum chamber fitted with a feedthrough and nozzle allowing fluid to be injected into vacuum. The nozzle dispersed the fluid into micron-sized droplets. Fluid containing a population of E. Coli microbes was injected into the chamber and droplets were collected on microscope slides and small cups for imaging with a Scanning Electron Microscope (SEM). Epifluorescence microscopy, using a lipid stain, and SEM imaging were used to evaluate the cellular integrity of E. coli after injection through the pressurized nozzle into vacuum. The experimental samples showed a 94% decrease in visible intact E. coli cells as compared with control samples but showed a fluorescent residue in the shape of the sublimated droplets that indicated the presence of lipids. E. coli was selected for testing although other cell types could vary physiologically which could affect their response to a vacuum environment. More testing is needed to determine whether other types of microbial cells can survive the plume environment. However, these results suggest that lipids may be directly detectable evidence of life in icy world plumes, but organisms are unlikely to survive due to disruption of their cell walls.

C. R. Stoker↗

Pre-Flight Characterization of Samples for the MISSE-7 Spacesuit Fabric Exposure Experiment

A series of six sample spacesuit pressure garment assembly (PGA) fabric samples were prepared for the Materials International Space Station Experiment 7 (MISSE-7) flight experiment to test the effects of damage by lunar dust on the susceptibility of the fabrics to radiation damage. These included pristine Apollo-era fluorinated ethylene-propylene (FEP) fabric, Apollo-era FEP fabric that had been abraded with JSC-1A lunar simulant, and a piece of Alan Bean s Apollo 12 PGA sectioned from near the left knee. Also included was a sample of pristine orthofabric, and orthofabric that had been abraded to two different levels with JSC-1A. The samples were characterized using optical microscopy, field emission scanning electron microscopy, and atomic force microscopy. Two sets of six samples were then loaded in space environment exposure hardware, one of which was stored as control samples. The other set was affixed to the MISSE-7 experiment package, and will be mounted on the International Space Station, and exposed to the wake-side low Earth orbit environment. It will be retrieved after an exposure of approximately 12 months, and returned for post flight analysis.

Gaier, James R.↗

Effect of Ionizing Radiation on the Mechanical and Structural Properties of Graphite Fiber Reinforced Composites

Graphite/epoxy (T300/5208) and graphite/polyimide composites (C6000/PMR 15) were exposed to various levels of 0.5 MeV electron radiation with the maximum dose being 10,000 Mrad. A three point bending test was used to evaluate the ultimate stress and modulus of the composites. In all composites except transverse samples of C6000/PMR 15 ultimate stress values remained approximately constant or increased slightly. The modulus values remained approximately constant for all composite types regardless of the radiation level. Interfacial aspects of composites were studied. Interlaminar shear tests were performed on T300/5208 and C6000/PMR 15 composites irradiated to 10,000 Mrad. There was an initial increase in interlaminar shear strength (up to 1,000 Mrad) followed by a sharp decrease with further radiation exposure. Using scanning electron microscopy no visual differences in the mode of fracture could be detected between ruptured control samples and those exposed to various levels of radiation. Electron spectroscopy for chemical analysis (ESCA) revealed little change in the surface elements present in control and highly irradiated T300/5208 composite samples.

Wolf, Kay Woodroof↗

Diode step stress program for JANTX1N4570A

The effect of power/temperature step stress when applied to a variety of semiconductor devices was evaluated. Performance of the zener diode JANTX1N4570A manufactured by Siemens and Motorola is reported. A total of 48 samples from each manufacturer was submitted to the process outlined in Table 1. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

Transister step stress testing program for JANTX2N3811

The effect was studied of power/temperature step stress when applied to the dual transistor JANTX2N3811 manufactured by Motorola and National Semiconductor. A total of 48 samples from Motorola and 47 from National Semiconductor was submitted to the processes. In addition, two control sample units were maintained for verification of the electrical parametric testing. The tests for determining power/temperature stresses are described, and test results are discussed. Failure analyses for power stress, and temperature stress are presented.

Source record↗

The effect of space flight on monoclonal antibody synthesis in a hybridoma mouse cell line

The hybridoma cell line, 3G10G5, producing a monoclonal antibody to the major capsid protein VP1 from the avian polyomavirus budgerigar fledgling disease virus, was produced from a Balb/C mouse. This cell line was used to test the effects of microgravity on cellular processes, specifically protein synthesis. A time course study utilizing incorporation of [35S]methionine into newly synthesized monoclonal antibody was performed on STS-77. After 5.5 days, it was observed that cell counts for the samples exposed to microgravity were lower than those of ground-based samples. However, radiolabel incorporation of the synthesized monoclonal antibody was similar in both orbiter and ground control samples. Overall, microgravity does not seem to have an effect on this cell line's ability to synthesize IgG protein.

manned↗

Transistor step stress program for JANTX2N2920

Data on the effect of power/temperature step stress when applied to the dual transistor JANTX2N2920 manufactured by Fairchild and National Semiconductor are presented. Fifty one (51) samples from Fairchild and 44 from National Semiconductor were submitted to the process outlined. In addition, two control sample units were maintained for verification of the electrical parametric testing.

Source record↗

A Digital Control Algorithm for Magnetic Suspension Systems

An ongoing program exists to investigate and develop magnetic suspension technologies and modelling techniques at NASA Langley Research Center. Presently, there is a laboratory-scale large air-gap suspension system capable of five degree-of-freedom (DOF) control that is operational and a six DOF system that is under development. Those systems levitate a cylindrical element containing a permanent magnet core above a planar array of electromagnets, which are used for levitation and control purposes. In order to evaluate various control approaches with those systems, the Generic Real-Time State-Space Controller (GRTSSC) software package was developed. That control software package allows the user to implement multiple control methods and allows for varied input/output commands. The development of the control algorithm is presented. The desired functionality of the software is discussed, including the ability to inject noise on sensor inputs and/or actuator outputs. Various limitations, common issues, and trade-offs are discussed including data format precision; the drawbacks of using either Direct Memory Access (DMA), interrupts, or program control techniques for data acquisition; and platform dependent concerns related to the portability of the software, such as memory addressing formats. Efforts to minimize overall controller loop-rate and a comparison of achievable controller sample rates are discussed. The implementation of a modular code structure is presented. The format for the controller input data file and the noise information file is presented. Controller input vector information is available for post-processing by mathematical analysis software such as MATLAB1.

Britton, Thomas C.↗

Understanding the Feasibility of MAB Phase Structures for Lunar Applications

During the ten-week internship, my work focused on synthesis, characterization, and tailoring the flowability of the MAB phase powders for improving the surface finish and decreasing porosity of 3D-printed MAB phase structures. My mentor for the project was Dr. Samuel Hocker from NASA Langley and my faculty advisor was Dr. Surojit Gupta from the University of North Dakota. I also collaborated with Daniel Trieff from the University of North Dakota in developing characterization paradigm of 3D printed samples. The microencapsulation was performed via novel solvent casting-based microencapsulation process pioneered in UND, wherein a polymer (PLA, PHA) was dissolved into dichloromethane and precipitated onto the surface of the MoAlB particles. Two 100mL samples of microencapsulated powder was outsourced to Particle Technology Labs for flowability testing along with a 100mL control sample to determine if microencapsulation is a valid method for improving the flowability. The microencapsulated powders were characterized using SEM, Differential Scanning Calorimetry, and optical microscopy. The SEM images showed no change between the pure and microencapsulated powders. The optical microscopy analysis indicated a reduction in reflectivity for the PLA microencapsulated powders as well as hydrophobic properties. Both results suggest that microencapsulation was successful as PLA is a hydrophobic polymer and the change in reflectivity could be a result of the light being dispersed through the polymer coating. A reflectivity analysis will be done to bring more perspective to these observations. If powder flowability is improved, then the project will move forward with testing the printability of the microencapsulated powders and characterizing the structures using the designed characterization protocol. We are waiting for the DSC results. The characterization protocol for the 3D-printed MAB structures included a visual inspection of the plates to rule out any samples that had spalled or delaminated, optical microscopy to document surface features, porosity, and decomposition, and cleaning of the plates using an ultrasonic bath in preparation for SEM, EDS, and profilometry analyses.

MAB Phase↗

Further Investigations of the Passive Optical Sample Assembly (POSA) - I Flight Experiment

The Passive Optical Sample Assembly-I (POSA-I), part of the Mir Environmental Effects Payload (MEEP), was designed to study the combined effects of contamination, atomic oxygen, ultraviolet radiation, vacuum, then-nal cycling, and other constituents of the space environment on spacecraft materials. The MEEP program is a Phase I International Space Station Risk Mitigation Experiment. Candidate materials for the International Space Station (ISS) were exposed in a specially designed "suitcase" carrier, with identical specimens facing either Mir or space. The payload was attached by EVA to the exterior of the Mir docking module during the STS-76 mission (f'ig. 1). It was removed during the STS-86 mission after an 18-month exposure. During the mission, it received approximately 7 x 1019 atoMS/CM2 atomic oxygen, as calculated by polymer mass loss, and 413 ESH of solar ultraviolet radiation on the Mir-facing side. The side facing away from Mir received significant contaminant deposition, so atomic oxygen fluence has not been reliably determined. The side facing away from Mir received 571 ESH of solar UV. Contamination was observed on both the Mir-facing and space-facing sides of the POSA-I experiment , with a greater amount of deposition on the space facing side than the Mir side. The contamination has been determined to be outgassed silicone photofixed by ultraviolet radiation and converted to silicate by atomic oxygen interaction. Electron spectroscopy for chemical analysis (ESCA) with depth profiling indicated the presence of 26 - 31 nm silicate on the Mir-facing side and 500 - 1000 nm silicate on the space-facing side. The depth profiling also showed that the contaminant layer was uniform, with a small amount of carbon present on the surface and trace amounts of nitrogen, phosphorus, sulfur, and tin. The surface carbon layer is likely due to post-flight exposure in the laboratory and is similar to carbonaceous deposits on control samples. EDAX and FTIR analysis concurred with ESCA for the presence of silicon, oxygen, and carbon. Nearly 400 samples were exposed on POSA-I, which included materials such as thermal control coatings polymeric films, optical materials, and multi-layer insulation blankets. A previous paper discussed the effects of the space environment exposure and contaminant deposition on candidate materials for ISS, including Z93P inorganic thermal control coating, various anodizes, and multi-layer insulation blankets. This paper details the investigation of environmental effects on the remainder of POSA-I samples, particularly the innovative conductive thermal control coatings developed by AZ Technology of Huntsville, AL and HT Research Institute of Chicago, IL. The silicone/silicate contamination had a significant impact on the solar absorptance of white inorganic thermal control coatings on the space-facing side of POSA-I. The effect of contamination on electrical conductivity is discussed. Samples of conductive anodized aluminum developed by Boundary Technologies of Buffalo Grove, IL were also exposed on POSA-I. The effects of the space environment and contaminant deposition on the optical and electrical properties of the conductive anodized aluminum are discussed.

Finckenor, Miria M.↗

Effects of high energy radiation on the mechanical properties of epoxy/graphite fiber composites

Studies on the effects of high energy radiation on graphite fiber reinforced composites are summarized. Studies of T300/5208 and C6000/PMR15 composites, T300 fibers and the resin system MY720/DDS (tetraglycidyl-4,4'-diaminodiphenyl methane cured with diaminodiphenyl sulfone) are included. Radiation dose levels up to 8000 Mrads were obtained with no deleterious effects on the breaking stress or modulus. The effects on the structure and morphology were investigated using mechanical tests, electron spin resonance, X-ray diffraction, and electron spectroscopy for chemical analysis (ESCA or X-ray photoelectron spectroscopy). Details of the experiments and results are given. Studies of the fracture surfaces of irradiated samples were studied with scanning electron microscopy; current results indicate no differences in the morphology of irradiated and control samples.

Fornes, R. E.↗