Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Shielding design for a chip irradiation test facility at SNS - Paper 119

As digital and analog circuits are more and more sophisticatedly integrated, they become increasingly susceptible to single event upsets (SEU), a cause of electronic equipment malfunction induced by cosmic rays with particular hazard potential for aviation equipment. Electronic chips sensitive to SEU have to be tested in a simulated comic ray environment to ensure their reliability. It is found that the spallation induced fast neutron spectrum is very close to the neutron spectrum of the cosmic ray. Hence, a conceptual design study of a chip irradiation test facility is funded by FAA to be carried out at SNS, the world's most powerful accelerator driven facility for neutron scattering studies on materials. Compared to existing/being construct chip irradiation test facilities at LANL and ISIS, SNS can provide wider neutron energy range and much higher fluxes. This study focuses on the aspect of shielding design for such a chip irradiation facility. A number of medium-weighted and heavy materials were examined for efficiency in reducing radiation dose rate. In general, the smaller the target monolith is while satisfying the personnel-protection-driven radiation dose rate limit at its outside, the closer to the target chips could be placed and thus less beam power it demands to satisfy a given irradiation flux requirement. Before proceed to the shielding design, the neutron source coming off the target has to be determined for selecting a best spot for chip irradiation test, in which the incoming fast neutron spectrum approximate most to the atmospheric radiation condition. It also provides a source term for the following shielding design of the irradiation enclosure. (authors)

36 MATERIALS SCIENCE↗

Effects of Gain Changes on RPM Performance

The mission of the U.S. Department of Energy/National Nuclear Security Administration's (DOE/NNSA's) Office of the Second Line of Defense (SLD) is to strengthen the capability of foreign governments to deter, detect, and interdict the illicit trafficking of special nuclear and other radioactive materials across international borders and through the global maritime shipping system. The goal of this mission is to reduce the probability of these materials being fashioned into a weapon of mass destruction or radiological dispersal device that could be used against the United States or its international partners. This goal is achieved primarily through the installation and operation of radiation detection equipment at border crossings, airports, seaports, and other strategic locations around the world. In order to effectively detect the movement of radioactive material, the response of these radiation detectors to various materials in various configurations must be well characterized. Oak Ridge National Laboratory (ORNL) investigated two aspects of Radiation Portal Monitor (RPM) settings, based on a preliminary investigation done by the Los Alamos National Laboratory (LANL): source-to-detector distance effect on amplifier gain and optimized discriminator settings. This report discusses this investigation. A number of conclusions can be drawn from the ORNL testing. First, for increased distance between the source and the detector, thus illuminating the entire detector rather than just the center of the detector (as is done during detector alignments), an increase in gain may provide a 5-15% increase in sensitivity (Fig. 4). However, increasing the gain without adjusting the discriminator settings is not recommended as this makes the monitor more sensitive to electronic noise and temperature-induced fluctuations. Furthermore, if the discriminators are adjusted in relation to the increase in gain, thus appropriately discriminating against electronic noise, the sensitivity gains are less than 5% (Fig. 6). ORNL does not consider this slight increase in sensitivity to be a worthwhile pursuit. Second, increasing the ULD will increase sensitivity a few percent (Fig. 7); however, it is not clear that the slight increase in sensitivity is worth the effort required to make the change (e.g., reliability, cost, etc.). Additionally, while the monitor would be more sensitive to HEU, it would also be more sensitive to NORM. Third, the sensitivity of the system remains approximately the same whether it is calibrated to a small source on contact or a large source far away (Fig. 6). This affirms that no changes to the existing calibration procedure are necessary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic Carbon Capture Development (Final Report)

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant. The specific areas of work in this project are: Budget Period 1: 1) Selection of the most energy-efficient drying system for ambient-pressure flue gas. Sustainable Energy Solutions, LLC (SES) has successfully demonstrated a dryer that removes bulk water using a low-temperature brine to remove about 99% of the water followed by a mol sieve 3A desiccant dryer to remove the remaining 1% water; 2) Selection and demonstration of efficient solution to fouling due to dissolved CO 2 . SES has tested several commercial heat exchangers that purport to be able to handle fouling issues similar to those experienced in the contact liquid chiller. Replicated tests using the CCC ECL™ skid and dimpled brazed plate heat exchangers demonstrate that quick throttling of refrigerant combined with a burst of clean gas mitigate the fouling caused by CO 2 solubility in contact liquid with only minor increases in parasitic load. SES models indicate that parasitic load would increase by approximately 0.0125 GJ/tonne, an order of magnitude less than what was determined to be the maximum allowable additional parasitic load caused by this system; 3) Selection and demonstration of efficient and scalable solid–liquid separation system. The screw press technology met or exceeded the 70% solids loading benchmark during several test runs exceeding 24 hours on the CCC ECL™ skid. The average solids loading during the entire 50-hour run was 67%. The energy demand for this system is less than 0.1 GJ e /tonne of CO 2 processed; 4) Optimize design and demonstration of patented desublimating heat exchangers. We designed and built a hybrid spray tower that was tested over many hundreds of hours and a 50-hour continuous test run was completed capturing over 0.5 tonne CO 2 /day at >90% capture; (5) Plan for safe dilution of oxygen-depleted, cleaned flue-gas stream. The AERSCREEN simulator developed by the EPA modeled the dispersion of oxygen-depleted flue gas from the CCC process at a commercial plant. The results indicate that this plan effectively mitigates the flue gas hazards; (6) Simulation of and experimental work related to multi-pollutant capture. SES programmed an upgrade to its solid/vapor/liquid equilibrium (SVLE) algorithm. This enables simultaneous modeling of multiple pollutants (i.e., CO 2 , SO x , NO x , Hg, HCl). Budget Period 2; (7) Modify the CCC ECL™ skid for field testing and complete shakedown testing. The plans for modifying the CCC ECL™ skid were finalized and put into place. Shakedown testing of the updated CCC ECL™ skid occurred at SES using closed-loop mode (i.e., using a synthetic flue gas consisting of only N 2 and CO 2 ) and at the Hunter Power Plant using flue gas from the coal-fired boiler. Shakedown testing took longer than expected due to delays in receiving equipment and unexpected equipment performance in the field; (8) Operate the CCC ECL™ skid in the field. Longer testing of the CCC ECL™ skid occurred at the Hunter Power Plant. Multiple tests exceeding 35 hours were completed, with a total of over 600 hours of CO 2 capture completed using flue gas at the Hunter Power Plant with an average CO 2 capture rate of over 91% during those hours. Extensive notes and documentation were acquired informing improved methods for controls, startup, operation, and shut down; (9) Determine figures of merit and quantify process improvement. SES defined figures of merit for unit operation performance and overall CCC ECL™ process performance. All figures of merit were achieved or surpassed, except for 500 continuous hours of demonstration at the Hunter Power Plant; (10) Complete an Environmental Health and Safety Risk assessment by a third party. Tri-State completed an Environmental Health and Safety Risk assessment; (11) Update techno-economic analysis with third-party validation. The techno-economic analysis has been completed. It confirms the potential large reduction in energy and cost of the CCC process compared with leading alternatives and that the estimates and estimation techniques are reliable.

20 FOSSIL-FUELED POWER PLANTS↗

Fit Fly: A Case Study of Interconnect Innovation through Parallel Simulation

To meet the demand for exascale-level performance from high-performance computing (HPC) interconnects, many system architects are turning to simulation results for accurate and reliable predictions of the performance of prospective technologies. Testing full-scale networks with a variety of benchmarking tools, including synthetic workloads and application traces, can give crucial insight into what ideas are most promising without needing to physically construct a test network. While flexible, however, this approach is extremely compute time intensive. We address this time complexity challenge through the use of large-scale, optimistic parallel simulation that ultimately leads to faster HPC network architecture innovations. In this paper we demonstrate this innovation capability through a real-world network design case study. Specifically, we have simulated and compared four extreme-scale interconnects: Dragonfly, Megafly, Slim Fly, and a new dual-rail-dual-plane variation of the Slim Fly network topology. We present this new variant of Slim Fly, dubbed Fit Fly, to show how interconnect innovation and evaluation-beyond what is possible through analytic methods-can be achieved through parallel simulation. We validate and compare the model with various network designs using the CODES interconnect simulation framework. By running large-scale simulations in a parallel environment, we are able to quickly generate reliable performance results that can help network designers break ground on the next generation of high-performance network designs.

High Performance Computing↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of Building Energy Modeling using Flexible Research Platform

Recently, efforts have been made to provide reliable empirical data for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, to enable improved accuracy of building energy model (BEM) engines and improved characterization of their accuracy. The motivation for this effort is that the use of reliable empirical validation data sets in the evaluation of building energy modeling tools will lead to more consistent and validated simulation engines across all software vendors. This would expedite the use of building energy modeling in designing new buildings and retrofitting existing buildings, which delivers more energy efficient buildings.As part of a three-year multi-lab empirical validation project sponsored by U.S. DOE, this research project generated cooling season test plans by reviewing ASHRAE Standard 140, and the tests were performed based on the test plan. Finally, the experimental data sets were compared with the EnergyPlus model to demonstrate the validation procedure.

Im, Piljae↗

Joint Architecture Standard (JAS) Reliable Data Delivery Protocol (RDDP) specification.

The Joint Architecture Standard (JAS) program at Sandia National Laboratories requires the use of a reliable data delivery protocol over SpaceWire. The National Aeronautics and Space Administration at the Goddard Spaceflight Center in Greenbelt, Maryland, developed and specified a reliable protocol for its Geostationary Operational Environment Satellite known as GOES-R Reliable Data Delivery Protocol (GRDDP). The JAS program implemented and tested GRDDP and then suggested a number of modifications to the original specification to meet its program specific requirements. This document details the full RDDP specification as modified for JAS. The JAS Reliable Data Delivery Protocol uses the lower-level SpaceWire data link layer to provide reliable packet delivery services to one or more higher-level host application processes. This document specifies the functional requirements for JRDDP but does not specify the interfaces to the lower- or higher-level processes, which may be implementation-dependent.

99 GENERAL AND MISCELLANEOUS↗

Cryogenic Carbon Capture Development Final/Technical Report

This project extends and leverages the work completed under funding from ARPA-E and other sources by exploring aspects of the Cryogenic Carbon Capture™ (CCC) process and issues discovered during those projects, but that were not within the scope or budget of previous projects or that became apparent during field tests. Our successful completion of the tasks outlined in this project has increased the reliability, efficiency, and scalability of the CCC process and we are better prepared for pilot-scale testing. The first phase of this project improved key areas of the process through iterative design and experiment, culminating with recommendations for improvements to the existing skid-scale system developed under non-federal funding. The second phase of this project implemented the improved unit operations into the Cryogenic Carbon Capture External Cooling Loop (CCC ECL™) skid and field tests the improved system at a coal-fired power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Regional Soiling Stations for PV: Soling Loss Analysis

The soiling loss factor (SLF) of photovoltaic (PV) modules/system is an interplay between the dust frequency and intensity of the site, rain frequency and intensity of the site, tilt angle and height of the module installation, and wind speed and humidity of the site. The integrated area of the downward peaks of the SLF time series plots for a year provides the annual soiling loss for the system at each tilt angle. Sandia National Laboratories, in collaboration with Arizona State University, installed five regional soiling stations around the country and collected soiling loss data over a year. Four of these soiling stations are located at the U.S. Department of Energy Regional Test Centers (Florida, Albuquerque, Colorado and Vermont), while the fifth station is located at the Arizona State University Photovoltaic Reliability Lab (Arizona). This paper presents an analysis on the SLF for each test site at ten different tilt angles. Based on the analysis of a yearlong data obtained in 2015, it appears to indicate that the Arizona site experienced the highest annual soiling loss with a significant dependence on the tilt angle while the other four sites experienced a negligibly small annual soiling loss with practically no dependence on the tilt angle.

14 SOLAR ENERGY↗

Software-Defined Virtual Synchronous Condenser

Synchronous condensers (SCs) play important roles in integrating wind energy into relatively weak power grids. However, the design of SCs usually depends on specific application requirements and may not be adaptive enough to the frequently-changing grid conditions caused by the transition from conventional to renewable power generation. This paper devises a software-defined virtual synchronous condenser (SDViSC) method to address the challenges. Our contributions are fourfold: 1) design of a virtual synchronous condenser (ViSC) to enable full converter wind turbines to provide built-in SC functionalities; 2) engineering SDViSCs to transfer hardware-based ViSC controllers into software services, where a Tustin transformation-based software-defined control algorithm guarantees accurate tracking of fast dynamics under limited communication bandwidth; 3) a software-defined networking-enhanced SDViSC communication scheme to allow enhanced communication reliability and reduced communication bandwidth occupation; and 4) Prototype of SDViSC on our real-time, cyber-in-the-loop digital twin of large-wind-farm in an RTDS environment. Furthermore, extensive test results validate the excellent performance of SDViSC to support reliable and resilient operations of wind farms under various physical and cyber conditions.

17 WIND ENERGY↗

Modification of Central Solenoid Model Coil Test Facility for Rapid Testing of CICC

This document describes preliminary design modifications to the CSMC Test Facility in JAEA, Naka, Japan that will allow rapid test and change-out of CS conductor samples while simultaneously achieving more precise and reliable characterization of those samples than is presently achievable elsewhere. The current philosophy for CS conductor testing is to test an Insert in CSMC followed by SULTAN testing. The SULTAN facility has very short length in field and a short length between the High Field Zone and the joints. This makes it difficult to obtain uniform distribution of current in the cable at low voltage levels, which defines the current sharing temperature. In a real magnet, like ITER CS, there is a long length of conductor in the highest field. Such conditions provide a more uniform current distribution near current sharing. The modified facility will serve as an economical tool for ITER conductor testing. The test item will be a three turn sample, approximately 15 m long, placed in the background field of the CSMC. This new mode of operation will reduce the time of cool-down, warm-up and installation of the sample into the CSMC facility, which should significantly reduce the cost of a test per sample.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerated Stress Testing on Multichannel Drivers—Updated Test Results

This report is the second in a series of studies about accelerated stress testing (AST) of drivers used for SSL luminaires. Two-stage drivers intended for use in downlights, troffers and street lights were selected to undergo exposure to an AST environment consisting of 75°C and 75% relative humidity (7575). The 7575 AST environment was chosen for this study because a previous study demonstrated that 38% of a sample population of 6-inch downlights failed in less than 2,500 hours in these conditions. A mixture of single-channel (i.e., one output current channel designed for use with one LED primary) and multichannel (i.e., separate output current channels designed for use with multiple for LED primaries) two-stage drivers were exposed to the 7575 environment. This report provides updated AST test results for only the multichannel driver products. The multichannel driver population consisted of three products (with two-stage architecture) and a total of five samples. In addition to AST results, the product life distribution (Weibull analysis) of two-stage driver Hammer Test samples is reported.

42 ENGINEERING↗

Simple Model Representations of Transport in a Complex Fracture and Their Effects on Long-Term Predictions

A complex fracture model for fluid flow and tracer transport was previously developed that incorporates many of the important physical effects of a realistic fracture, including advection through a heterogeneous fracture plane, partitioning of flow into multiple subfractures in the third dimension, and diffusion and sorption into fracture-filling gouge, small altered rock matrix blocks within the fracture zone, and the unaltered semi-infinite rock matrix on both sides of the fracture zone (Tsang and Doughty, 2003). It is common, however, to represent the complex fracture by much simpler models consisting of a single fracture, with a uniform or heterogeneous transmissivity distribution over its plane and bounded on both sides by a homogeneous semi-infinite matrix. Simple-model properties are often inferred from the analysis of short-term (one to a few days) site characterization (SC) tracer-test data. The question addressed in this paper is: How reliable is the temporal upscaling of these simplified models? Are they adequate are for long-term calculations that cover thousands of years? In this study, a particle-tracking approach is used to calculate tracer-test breakthrough curves (BTCs) in a complex fracture model, incorporating all the features described above, for both a short-term SC tracer test and a 10,000-year calculation. The results are considered the 'real-world'. Next, two simple fracture models, one uniform and the other heterogeneous, are introduced. Properties for these simple models are taken either from laboratory data or found by calibration to the short-term SC tracer-test BTCs obtained with the complex fracture model. Then the simple models are used to simulate tracer transport at the long-term time scale. Results show that for the short-term SC tracer test, the BTCs calculated using simple models with laboratory-measured parameters differ significantly from the BTCs obtained with the complex fracture model. By adjusting model properties, the simple models can be calibrated to reproduce the peak arrival time and height of the complex-fracture-model BTCs, but the overall match remains quite poor. Using simple models with short-term SC-calibrated parameters for long-term calculations causes order-of-magnitude errors in tracer BTCs: peak arrival time is 10-100 times too late, and peak height is 50-300 times too small. On the other hand, using simple models with laboratory-measured properties of unfractured rock samples for 10,000-year calculations results in peak arrivals and heights up to a factor of 50 too early and large, respectively. The actual magnitudes of the errors made by using the simple models depend on the parameter values assumed for the complex fracture model, but in general, simple models are not expected to provide reliable long-term predictions. The paper concludes with some suggestions on how to improve long-term prediction calculations.

54 ENVIRONMENTAL SCIENCES↗

Lessons from the IEC Durability of Adhesion Accelerated Test Sequence

The IEC 62788-1-1 and IEC 63209-2 standards use aging sequences for durability of adhesion in photovoltaic (PV) modules, which may be evaluated using the single cantilever beam (SCB) test. Because the encapsulant forms critical interfaces with the front glass and solar cells, degradation at those interfaces under ultraviolet (UV) exposure, elevated temperature, and humidity can lead to interfacial delamination - compromising the long-term reliability. In this work, adhesion durability of UV-transmitting poly(ethylene-co-vinyl acetate) (EVA) encapsulant to glass and to silicon solar cells is evaluated after sequenced UV and damp heat aging (85C/85%RH). Laminates were prepared using StarPhire solar front glass with thin glass or PERC cells, and two EVA formulations with different concentrations of siloxane coupling agent. Adhesion was quantified by measuring critical debond energy using the SCB method. Both formulations exhibit similar qualitative trends, while different adhesion is observed at the periphery despite the use of low-shrink manufacturing. The results show that while glass/EVA adhesion remains stable or increases after UV exposure and shows only moderate changes after damp heat, the EVA/cell interface exhibits an irreversible loss of adhesion following UV and then damp heat exposure. Although glass/EVA interfaces generally exhibit lower debond energies, the EVA/cell interface is significantly more vulnerable to UV-driven degradation, identifying it as the dominant reliability risk location through early- and intermediate-module life. These results demonstrate that accelerated aging sequences can expose large, interface-specific losses in adhesion durability and underscore the importance of interface engineering for long-term PV module reliability.

14 SOLAR ENERGY↗

PHASE II VAULT TESTING OF THE ARGONNE RFID SYSTEM

The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault. Deploying the ARG-US RFID system lends to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including radiation and environmental monitoring. The successful completion of the testing program will provide field data to support future development and testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis on Over 10,000 Cores

Contingency analysis studies are necessary to assess the impact of possible power system component failures. The results of the contingency analysis are used to ensure the grid reliability, and in power market operation for the feasibility test of market solutions. Currently, these studies are performed in real time based on the current operating conditions of the grid with a set of pre-selected contingency list, which might result in overlooking some critical contingencies caused by variable system status. To have a complete picture of a power grid, more contingencies need to be studied to improve grid reliability. High-performance computing techniques hold the promise of being able to perform the analysis for more contingency cases within a much shorter time frame. This paper evaluates the performance of counter-based dynamic load balancing schemes for a massive contingency analysis program on 10,000+ cores. One million N-2 contingency analysis cases with a Western Electricity Coordinating Council power grid model have been used to demonstrate the performance. The speedup of 3964 with 4096 cores and 7877 with 10240 cores are obtained. This paper reports the performance of the load balancing scheme with a single counter and two counters, describes disk I/O issues, and discusses other potential techniques for further improving the performance.

Balancing Schemes for Massive Contingency↗

DARHT status and preparations for dual-axis hydrotesting (u)

The status of the DARHT facility, including a history of events that have taken place since the end of the DARHT Second Axis Refurbishment Project, is discussed. Technical and operational enhancements that have been made will be addressed, and recent technical challenges, such as the RF noise in the kicker region, are discussed. Historical data on reliability of the second axis is discussed, as well as operational changes made to enhance reliability. In addition, the path forward for integrating the second axis into overall DARHT operations in preparation for a hydrotest is addressed. Timing integration tests are accompanied by a series of tests to evaluate neutron contamination and cross-axis scatter, with attempts being made to provide adequate shielding to minimize the effects of neutrons and cross-beam scatter. The discussion includes results of the testing performed to-date, and concludes with a discussion of the path forward for dual-axis hydrotesting at DARHT.

43 PARTICLE ACCELERATORS↗