Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON FLUX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a Fast Spectrum Test Loop at the Advanced Test Reactor

The United States currently has no infrastructure to provide a fast neutron flux for research purposes. With the increased interest in Sodium Fast Reactor (SFR) technology, this type of infrastructure is necessary for further development of key components such as Versatile Test Reactor. The purpose of this research is to characterize the thermal hydraulics of a test loop capable of providing SFR like operating conditions. This includes showcasing feasibility in mechanical design, reaching a high fast to thermal neutron flux ratio ideally near 15, an inlet temperature of 600 K, a temperature increase of 50 K from inlet to outlet, and test chamber radial temperature profiles similar to SFR fuel rods. Existing infrastructure must be used to provide the neutron flux for the test loop, and it was decided that the Advanced Test Reactor (ATR) was the optimal choice due to its availability and previous work conducted similar to this project. To achieve the goals of this project, several mechanical designs were put forward with the most feasible design being chosen. The neutronics and thermal hydraulics analysis were conducted in tandem, with an iterative process used to maximize efficiency of both systems. Analysis of the neutronics system was done using Attila and MCNP while the thermal hydraulic analysis was done using RELAP5. This document outlines the thermal hydraulic analysis, though it includes the results from the mechanical design and neutronics analysis. The loop design includes a primary system with molten sodium, a set of “booster fuel plates” to increase the fast flux within the test section, a water system to cool the booster fuel plates, a helium system to separate the sodium and water systems, and a thermal neutron shield to decrease the thermal flux. Each of these systems is modeled in the neutronics and thermal hydraulic analyses. The RELAP5 model showcased the feasibility of the design proposed by this report. For all designs tested, the desired 50 K temperature increase from inlet to outlet was reached. The fuel rod radial temperature profile was lower than was expected, likely due to a lower rod thermal power than expected. A parametric study was also conducted to characterize the system with three fuel pins. This study showed the effect of thermal power, fluid pressure, fluid velocity, and inlet temperature on the system. ©Copyright by Anton Higgins December 11, 2019 All Rights Reserved

99 GENERAL AND MISCELLANEOUS↗

Flux Characterization of Washington State University’s Epithermal Neutron Beam Facility

The neutron flux of the epithermal neutron beamline facility at the Washington State University (WSU) Research reactor was characterized as part of a research effort between Pacific Northwest National Laboratory (PNNL) and WSU to better understand the effects that neutron interaction has on the release of hydrogen from zirconium hydride. This effort was to confirm that the spectrum was epithermal, and that the magnitude of the flux was adequate for the needs of the PNNL research efforts.

Zipperer, Travis J. [BATTELLE (PACIFIC NW LAB)]↗

Search for Lightly Ionizing Particles in SuperCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e /(3 × 10 5 ) as well as the strongest limits for charges ≤ e /160, with a minimum intensity of 1.36 × 10 -7 cm -2 s -1 sr -1 at charge e /160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulation study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10 -6 cm -2 s -1 . The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.

Banik, Samir↗

Search for lightly ionizing particles in superCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e/(3 × 105) as well as the strongest limits for charges ≤ e/160, with a minimum intensity of 1.36 × 10-7 cm-2s-1sr-1 at charge e/160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulationmore » study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10-6 cm-2s-1. The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.« less

Banik, Samir↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Investigation of neutron noise in a micro-scale, natural circulation molten salt fission battery system

The Molten Salt Reactor (MSR) concept is a rapidly evolving Generation IV design that has recently attracted favorable attention due to the potential for reducing waste generation, realizing passive safety features, and seizing on the opportunity for cost effective economics. A specific novel micro-MSR, natural circulation, battery design concept involves placing all primary components within a single reactor vessel containment without the need of primary forced pumping. This small modular, integral design presents potential cost savings while producing safety, reliable, and transportable carbon-free power for decades. This investigation evaluates the neutron noise induced by density and flow fluctuations in a natural circulation MSR battery concept being developed at the University of Idaho. This study finds numerical solutions to the one-dimensional, one-group, coupled diffusion equations for a bare, homogeneous core, and evaluates neutron flux and delayed neutron precursor concentration noise due to core flow and fuel salt density perturbation sources. Noise analysis shows both point kinetic and space-dependent behavior is present despite the small size, low-flow, closely-coupled nature of the natural circulation MSR concept. Analysis shows that the low flow of the convective system results in noise behavior typically representative of a larger forced-circulation MSR system. Finally, noise techniques may also be useful in MSR core diagnostics as a non-invasive, low-cost radiological option to traditional monitoring schemes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Particle Swarm Optimisation for group structure optimization for radiotherapy shielding

Neutron transport simulations are ubiquitous in nuclear engineering because they allow one to model experimental systems and render a model platform for easy perturbation of experimental designs. In addition, simulations allow one to gain experimental insight without actually having to go through the trouble of building a physical experiment. Neutron transport simulations can be stochastic or deterministic based. Stochastic neutron transport simulations are typically simulated using the Monte Carlo method and yield very accurate solutions but are computationally expensive, while deterministic methods are typically faster but can be less accurate. Here we focus on optimizing the accuracy of deterministic neutron transport simulations for radiotherapy simulations. Deterministic neutron transport requires discretization of angle, energy, and space to appropriately analyze the system one is trying to model. Discretization of energy is challenging because of the highly variable neutron flux at certain neutron energies. Improper discretization of energy in the transport model can lead to erroneous results and therefore inaccurate interpretations of the solution. In this study, we evaluate Particle Swarm Optimization (PSO) as a mechanism for selecting optimal group structures for radiotherapy shielding. We tested the particle swarm optimization algorithm on radiotherapy shielding problems using Los Alamos National Laboratory's (LANL) main deterministic transport code PARTISN. Results show that the optimized energy group structures generated from the optimization algorithm outperformed LANL's standard energy group structures, and therefore demonstrate utility in using PSO to expedite computation times due to the increased accuracy obtained with a smaller but optimized group structure. (authors)

43 PARTICLE ACCELERATORS↗

Critical response to M. Worrall et al. Published in Annals of Nuclear Energy 207 (2024) 110731

M. Worrall et al. recently published a manuscript titled “Fast neutron irradiation capability in existing thermal test reactors” (Worrall, 2024) that summarizes an irradiation vehicle design that would boost the fast neutron flux in the Advanced Test Reactor (ATR) for testing of nonfuel materials in a neutron flux energy spectrum that is more representative of fast reactors. Here, the authors compare their design with a separate vehicle design that they conceived of that would be implemented within the High Flux Isotope Reactor (HFIR). They analyzed both designs and drew conclusions on the most realistic near-term options for shielded nonfuel material irradiations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of muon-induced high-energy neutrons from rock in an underground Gd-doped water detector

In this paper, we present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results with the expected rate of correlated neutron captures arising from high-energy neutrons incident on the outside of the WATCHBOY shield, predicted by a hybrid FLUKA/GEANT4-based simulation. The incident neutron energy distribution used in the simulation was measured by a fast neutron spectrometer, the 1.8-ton Multiplicity and Recoil Spectrometer (MARS) detector, at the same depth. We nd that the measured detection rate of two correlated neutrons is consistent with that predicted by simulation. The result lends additional confidence in the detection technique used by MARS, and therefore in the MARS spectra as measured at three different depths. Confirmation of the fast neutron flux and spectrum is important as it helps validate the scaling models used to predict the fast neutron fluxes at different overburdens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Irradiation Testing of Nuclear Flux Sensors - Presentation for 2021 ASI Annual Webinar

This power point presentation is a summary of the work produced in FY2021 under the Irradiation Testing of Neutron Flux Sensors project funded by DOE's Advanced Sensor Initiative, and the outlook for FY22. The objective of this portion of the ASI program is to "Test and demonstrate in-pile instrumentation in conditions similar to those expected to be seen in service, i.e., the conditions they would see in either in irradiation experiments supporting advanced reactors, or ultimately, in advanced reactors themselves". The presentation describes how neutron flux sensors were tested in four INL reactors plus Idaho State University's research reactor during FY2021, and the results obtained from these tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integral Experiment on Polyethylene Using Radiative Capture in Indium Foils in a High Flux D-D Neutron Generator

In this work, we report here the results of a measurement of the scattered versus unscattered neutron fluence on polyethylene determined via neutron activation of multiple natural indium foils from a deuterium-deuterium (D-D) neutron generator. The neutrons were produced by the High Flux Neutron Generator (HFNG) at the University of California, Berkeley, a specially designed source to maximize neutron flux on a sample while minimizing the total neutron yield. During the experiment, approximately 10 8 n/s were produced with the energies at the indium foils ranging from 2.2 to 2.8 MeV. Both the angle-integrated and the partial angle differential results are consistent with the predictions of the Monte Carlo N-Particle Transport (MCNP) code, using ENDF/B-VII.1. This supports shielding calculations in the fast energy region with high-density polyethylene.

42 ENGINEERING↗

AGC-2 Graphite Preirradiation Data Analysis Report

This report describes the specimen loading order and documents all preirradiation examination material property measurement data for graphite specimens contained within the Second Advanced Graphite Capsule (AGC 2) irradiation capsule. The AGC 2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens in order to garner quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear grade graphites. This testing will ascertain the in service behavior of the graphite for pebble bed and prismatic very high temperature reactor designs. Similar to the First Advanced Graphite Capsule (AGC 1) preirradiation examination report, material property tests were conducted on specimens from 18 nuclear grade graphite types. However, AGC 2 tested an increased number of specimens (i.e., 512) prior to loading them into the AGC 2 irradiation assembly. All AGC 2 specimen testing was conducted at Idaho National Laboratory from July 2009 to August 2010. This report also details the specimen loading methodology for graphite specimens inside the AGC 2 irradiation capsule. The AGC 2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid plane. This provides similar specimens with and without an applied load. Analysis in this document utilizes the neutron flux profile calculated for the AGC 2 capsule design, the capsule dimensions, and the size (i.e., length) of the selected graphite specimens to create a stacking order that produces “matched pairs” of graphite specimens above and below the AGC 2 capsule elevation mid point, thus providing specimens with similar neutron dose levels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scoping Study for Fast Flux Testing in the Advanced Test Reactor

The value of fast spectrum reactors remains prominent in the nuclear technology portfolio. The performance of these reactors can be maximized with advancements in nuclear fuel technologies, but development of these technologies is currently held back by lack of fast spectrum test reactors available to the United States. Spectral modification of experiment positions in the thermal spectrum Advanced Test Reactor (ATR) has long been used to support fast reactor fuel development, but these methods have not been progressed to their full potential. This study investigated the use of concentric rings of aluminum-clad fuel plates in ATR flux traps and thermal neutron absorbing filters to increase fast neutron flux on test specimens. This concept was termed the Boosted Energy Advanced Spectrum Test (BEAST). This approach will enable irradiation of advanced fuel designs in prototypic-length fuel pins and representative flux environment to support post irradiation exams, enable transient testing, and produce the type of data that will permit lead test assembly irradiations in true Sodium Fast Reactors (SFRs) when they become available. Neutronic predictions were performed to investigate BEAST design options and thermal hydraulic models were produced to ensure feasibility of BEAST. Two versions were considered based on the geometric limitations of ATR’s small and large flux traps. The small version was found to be preferable due to slightly higher fast flux and fast-to-thermal neutron ratio. Perhaps more influentially, the small flux trap option was also preferred to avoid conflict with ongoing very high temperature reactor fuel irradiation programs in ATR’s large northeast flux trap. The small flux trap option provided less than half the test volume of the large version, but still had adequate volume for seven SFR pins in cross section which could be stacked two-high in ATR’s 1.2m long core to accommodate up to 14 EBR-II size pins. The preference for the small flux trap configuration should be revisited if additional collaborative test programs emerge with the need to irradiate a significant volume of additional specimens. Calculations were performed regarding a lithium deuteride ring to convert thermal neutrons into 14 MeV fusion neutrons. At the time this report was written these calculations were partially complete and it remains to be seen whether the concept would be worth including in BEAST. Given the preference for the small flux trap option, which does not afford enough room for the 14 MeV ring, it was concluded to defer future work on the lithium deuteride ring. This decision could be revisited if fusion material research programs emerge for collaborative testing in BEAST. A cadmium-lined specimen holder design was found to be adequate in filtering thermal neutrons and preferred over other neutron absorbers based on past experience with cadmium baskets. It was acknowledged that cadmium-bearing hardware would become depleted and need to be replaced occasionally, which appeared feasible from a mechanical design perspective. Neutronic studies investigated different enrichment levels in the booster fuel using uranium-molybdenum alloy dispersion fuel which has performed well in past ATR irradiations. Both options were able to drive fuel pins to SFR-like fission heating rates. The high enriched booster fuel option outperformed the low enriched option by ~20% on key metrics including fast flux and fast-to-thermal ratio, but the low enriched option was favored in order to broaden options for potential fuel suppliers. The preferred BEAST design options including cadmium filter with low enriched booster fuel in the small flux trap configuration was predicted to achieve 6.2E14 n/cm2sec fast flux (>0.1 MeV) with a fast-to-thermal ratio of 44.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of WIRE-21 SPND and Optical Fiber Sensor Measurements

The Wireless Instrumented RB Experiment 2021 (WIRE-21) was a highly instrumented experiment designed to test prototype wireless temperature and pressure sensors developed by Westinghouse Electric Corporation (WEC) in the High Flux Isotope Reactor (HFIR). In addition to these sensors, a suite of other sensors was also integrated into the experiment capsule, including various types of distributed optical fiber sensors and self-powered neutron detectors (SPNDs). This report presents an analysis of the data generated by the SPNDs and optical fiber sensors that were tested under the highest reported neutron flux. The distributed optical fiber sensor results demonstrate that F-doped optical fibers, particularly those inscribed with fs fiber Bragg gratings (FBGs), are capable of surviving fast neutron fluences on the order of 1021 n fast /cm 2 at temperatures relevant to light-water reactors (between 200 and 400°C). However, a significant blue-shift in the optical spectra of these sensors was observed over the course of irradiation which cannot be explained based on the current understanding of radiation-induced compaction in fused silica glass. A mechanistic understanding of this drift has not yet been developed and is proposed as future scope under the Advanced Sensors and Instrumentation program. Of the four SPNDs, only one appeared to operate normally during three cycles of irradiation. A radiation transport model of the experiment in HFIR was used to determine time-dependent neutron flux in this SPND and to calculate the neutron sensitivity of the device. Results showed a cycle averaged sensitivity of 1.5 ×10 -22 and 1.4 ×10 -22 A/nν for the first and third cycles of irradiation, respectively. Additional details pertaining to the optical fibers and SPNDs are included herein.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗