Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scenario optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ELM control optimization for various ITER scenarios based on linear and quasi-linear figures of merit

For the purpose of better understanding type-I edge localized mode (ELM) control in ITER with resonant magnetic perturbation (RMP) fields, the plasma response to RMP is computed by a resistive full magneto-hydrodynamic model in toroidal geometry. Five scenarios designed for ITER are considered, ranging from the pre-nuclear to nuclear phases. The plasma response to RMP is quantified by the plasma surface displacement near the X-point of the divertor plasma and at the outboard mid-plane. The optimal coil configurations between two high- Q deuterium-tritium (DT) scenarios (at the same plasma current of 15 MA and the same magnetic field of 5.3 T but different fusion gains, Q = 5 and 10) are predicted to be similar. For the other ITER scenarios with similar edge safety factor q 95 ~ 3 to that of the baseline scenario, the optimal coil phasing is also similar. The optimization results are different for a half-current full-field (7.5 MA/5.3 T) scenario, largely due to the difference in q 95 . The RMP coil currents are also optimized to tailor the core vs edge toroidal torques exerted by the 3D RMP fields on the plasma column. Torque optimization, with various objective functions proposed in the study, is useful for minimizing the side effects of RMP on the plasma core flow in ITER, while still maintaining the ELM control capability. Full utilization of three rows of ELM control coils in ITER is found to be essential to ensure both flexibility and robustness of ELM control, in terms of both linear and quasilinear plasma responses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal mitigation and control over power system dynamics for stochastic grid resilience

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the western system coordinating council 9-bus test system using synthetic multi-device outage scenarios.

30 DIRECT ENERGY CONVERSION↗

Dynamics Informed Optimization for Resilient Energy Systems

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the Western System Coordinating Council (WSCC) 9-bus test system using synthetic multi-device outage scenarios. Towards integrating our modeling framework with real threats and more realistic power systems, we explore applying hybrid dynamics to power systems. Our work is applied to basic RL circuits with the ultimate goal of using the methodology to model protective tripping schemes in the grid. Finally, we survey mitigation techniques for HEMP threats and describe a GIS application developed to create threat scenarios in a grid with geographic detail.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Optimal Mitigation Planning For Adversarial Scenarios

We propose a generalized framework which performs an optimal partitioning of a limited budget into various organizational sectors in order to improve the cybersecurity of a smart device or component in the Cyber Physical Energy System (CPS). The framework identifies the adversarial threats and possible attack sequences which can be performed to exploit cyber vulnerabilities of the component. Thereafter, we formulate an Mixed Integer Linear Programming (MILP) optimization problem which aims to evaluate the optimal budget partitions in order to minimize the number of highly likely attack sequences. Though we provide results for using the framework in CPES, the proposed methodology can be extended for multiple domains with a set of known adversarial and mitigation actions.

Purohit, Sumit [Pacific Northwest National Laborat↗

Toward real-time optimization through model reduction and model discrepancy sensitivities

Optimization problems arise in a range of scenarios, from optimal control to model parameter estimation. In many applications, such as the development of digital twins, it is essential to solve these optimization problems within wall-clock-time limitations. However, this is often unattainable for complex systems, such as those modeled by nonlinear partial differential equations. One strategy for mitigating this issue is to construct a reduced-order model (ROM) that enables more rapid optimization. In particular, the use of nonintrusive ROMs—those that do not require access to the full-order model at evaluation time—is popular because they facilitate the computation of optimization solutions within the wall-clock time requirements. However, the optimization solution will be unreliable if the iterates move outside the ROM training data. This article proposes the use of hyper-differential sensitivity analysis with respect to model discrepancy (HDSA-MD) as a computationally efficient tool to augment ROM-constrained optimization and improve its reliability. The proposed approach consists of two phases: (i) an offline phase where several full-order model evaluations are computed to train the ROM, and (ii) an online phase where a ROM-constrained optimization problem is solved, a limited number of full-order model evaluations are computed, and HDSA-MD is used to enhance the optimization solution. Numerical results are demonstrated for two examples, atmospheric contaminant control and wildfire ignition location estimation, in which a ROM is trained offline using inaccurate atmospheric data. In conclusion, the HDSA-MD update yields a significant improvement in the ROM-constrained optimization solution using only one full-order model evaluation online with corrected atmospheric data.

PDE-constrained optimization↗

SEAS Communication Engine: An Extensible, Flexible Wrapper for Co-Simulation Agents

When modeling and analyzing the power grid and other large scale systems, researchers often express scenarios as optimization problems and feed them into advanced software solvers. In order to allow multiple solvers to communicate with each other and share data from different domains, the National Renewable Energy Laboratory (NREL) and associated Department of Energy (DOE) labs have developed a software framework called the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS). HELICS allows cosimulation via a collection of client libraries for different languages that can be called from the appropriate optimization software. However, these client libraries do not provide a higher level of abstraction beyond reading and writing data off of the shared HELICS bus. In this paper, we describe a new software library called the SEAS Communication Engine that exposes a higher-level API for running cosimulation problems. The SEAS Engine provides a class-based abstraction on top of the Python HELICS client, in order to allow users to implement their domain-specific cosimulations without needing to interact with core HELICS primitives. This will make adoption of HELICS and cosimulation in general easier, by exposing a simpler API. In the second part of the paper, we validate our library on a collection of different simulation examples, including the canonical IEEE 13 Bus Feeder. Lastly, we demonstrate using the SEAS Engine to directly call domain-specific code written in the Julia programming language. Our hope is that this will serve as a template for easily calling software in different programming languages via the SEAS Engine, thereby avoiding code duplication and complexity.

co-simulation↗

Valued peaks: Sustainable water allocation for small hydropower plants in an era of explicit ecological needs

Optimizing hydropower operations to balance economic profitability and support functioning ecosystem services is integral to river management policy. In this article, we propose a dynamic, constrained optimization framework for small hydropower plants (SHPs) to evaluate trade-offs between economic profitability and socio-ecological requirements. Specifically, we examine the balance between short-term losses in hydropower generation and the potential for compensatory benefits in the form of revenue from recreational ecosystem services, irrespective of the direct beneficiary. Our framework integrates a fish habitat model, a hydropower optimization model, and a recreational ecosystem service estimate to evaluate different environmental flow scenarios. The optimization process gives three outflow release scenarios, informed by previous streamflow realisations (dam inflow), and designed environmental flow constraints. The framework is applied and tested for the river Kuusinkijoki in North-eastern Finland, which is a habitat for migratory brown trout and grayling populations. We show that the revenue loss due to the environmental flow constraints arises through a reduction in revenue per generated energy unit and through a reduction in turbine efficiency. Additionally, the simulation results reveal that all the designed environmental flow constraints cannot be met simultaneously. Under the environmental flow scenario with both minimum flow and flow ramping rate constraints, the annual hydropower revenue decreases by 16.5 %. An annual increase of 8 % in recreational fishing visits offsets the revenue loss. In conclusion, the developed framework provides knowledge of the costs and benefits of hydropower environmental flow constraints and guides the prioritizing process of environmental measures.

13 HYDRO ENERGY↗

CAMEO: A Co-design Architecture for Multi-objective Energy System Optimization (Project Report)

CAMEO (Codesign Architecture for Multi-objective Energy System Optimization) is a modular workflow management framework that abstracts co-design problems as Directed Acyclic Graphs (DAG). The framework employs JSON-based workflow specifications that enable systematic decomposition of complex optimization problems into reusable, interchangeable components including data loaders, scenario generators, optimization solvers, and result summarizers.

97 MATHEMATICS AND COMPUTING↗

Discovering the Most Severe K-Point Failure Based on Reinforcement Learning: Preprint

Smart devices are essential to ensure the stability of the power grid and resilience to intermittent energy production. However, smart devices can also be the target of cyber adversaries that may exploit false data injection attacks (FDIAs) to induce unstable grid conditions. A practical consideration of FDIA mitigation approaches is addressed here: given a finite available budget, for which smart device should cyber-threat mitigation be deployed first? In this work, this question is answered by identifying the so-called most-sensitive devices, i.e., the devices that, if compromised, can let an adversary induce the most serious grid instabilities. The method proposed utilizes an adversarial reinforcement learning (RL) framework to identify the k-mostsensitive smart devices (here, smart inverters). The adversarial agent can tamper with the compromised inverters' active and reactive operating power setup points, with the goal of maximizing voltage deviations. Numerical results show that the proposed RL method finds the optimal attack scenarios for 1-point failure and the near-optimal solution for the 2-point case. Additionally, the proposed RL method achieves an 8.8 speed-up ratio in running time compared to the brute force method for the 2-point case.

97 MATHEMATICS AND COMPUTING↗

SERA: A Hydrogen Infrastructure Capacity Expansion Model

The Scenario Evaluation and Regionalization Analysis (SERA) model is an infrastructure planning optimization model that can guide hydrogen production, delivery, and end-use investment decisions and accelerate the adoption of low-cost hydrogen at scale, whether for fuel cell electric vehicles or non-transportation applications. In this talk, we will review the SERA model objective function as well as the data inputs and outputs. We will also look at a SERA case study identifying potential dispensed costs of hydrogen along major refueling corridors throughout the United States. In addition to the SERA model, Justin will also discuss his recent work for the Office of Manufacturing and Energy Supply Chains on electrolyzer supply chain readiness, and his work for the Hydrogen Fuel Cell Technologies Office and Environmental Protection Agency on the levelized cost of dispensed hydrogen for heavy-duty trucking.

30 DIRECT ENERGY CONVERSION↗

Catalytic enhancement in the performance of the microscopic two-stroke heat engine

Here we consider a model of heat engine operating in the microscopic regime: the two-stroke engine. It produces work and exchanges heat in two discrete strokes that are separated in time. The working body of the engine consists of two d-level systems initialized in thermal states at two distinct temperatures. Additionally, an auxiliary nonequilibrium system called catalyst may be incorporated with the working body of the engine, provided the state of the catalyst remains unchanged after the completion of a thermodynamic cycle. This ensures that the work produced by the engine arises solely from the temperature difference. Upon establishing the rigorous thermodynamic framework, we characterize twofold improvement stemming from the inclusion of a catalyst. Firstly, we prove that in the noncatalytic scenario, the optimal efficiency of the two-stroke heat engine with a working body composed of two-level systems is given by the Otto efficiency, which can be surpassed by incorporating a catalyst with the working body. Secondly, we show that incorporating a catalyst allows the engine to operate in frequency and temperature regimes that are not accessible for noncatalytic two-stroke engines. We conclude with a general conjecture about the advantage brought by a catalyst: including the catalyst with the working body always allows to improve efficiency over the noncatalytic scenario for any microscopic two-stroke heat engines. We prove this conjecture for two-stroke engines where the working body is composed of two d-level systems initialized in thermal states at two distinct temperatures, as long as the final joint state leading to optimal efficiency in the noncatalytic scenario is not a product state, or at least one of the d-level system is not thermal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FORCE-DISPATCHES Integration - Initial Demonstration

Integrated energy systems (IES) combine, in mutually beneficial ways, power from variable renewable energy sources and nuclear power plants (NPP) to improve economic viability under uncertain market and weather conditions. The open-source Framework for Optimization of Resources and Economics (FORCE) tool suite, developed at Idaho National Laboratory (INL), has enabled comprehensive modeling and simulation of IES. The capabilities within FORCE include grid portfolio optimization through the Holistic Energy Resource Optimization Network (HERON) and the transient process model analysis library HYBRID, among others. Continuous efforts and investments from the IES programs have been made to expand and improve the versatility of the FORCE toolset in fiscal year 2022. Code-coupling and cross-tool communication have been important methods for improving this versatility. This report focuses on an additional workflow in the HERON tool for capacity and dispatch stochastic optimization through integration with the external tool Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES). DISPATCHES was primarily developed by the National Energy Technology Laboratory, in collaboration with other national laboratories, which included INL, universities, and industry partners. It is coupled to a library of algebraic models for specific plant components, and to a framework for stochastic optimization different from that provided in the current Risk Analysis Virtual Environment (RAVEN)-running-RAVEN algorithm in HERON. HERON currently conducts stochastic optimization via an outer-inner loop: it optimizes over variable capacity on the outer loop, and at each step within the capacity parameter space, conducts an inner optimization over scenarios (of market signals, demand, and/or weather patterns) and hourly dispatch throughout a user-specified number of years. On the other hand, DISPATCHES conducts stochastic optimization via an “all-at-once” strategy in which capacity variables are optimized at the same level as dispatch variables, as all scenarios are considered at once. The latter method works especially well for projects of limited size and project length, as the necessary computational power and memory increases with the number of variables and scenarios. The new capability to use the DISPATCHES workflow in HERON enhances standalone simulations by leveraging FORCE tools—namely, the economic metrics from the Tool for Economic Analysis (TEAL) and reduced-order model (ROM) sampling from RAVEN. The initial demonstration of the DISPATCHES workflow simulates an existing nuclear-case flowsheet within the DISPATCHES repository—this models a NPP with a secondary revenue stream for hydrogen production. Electrical output from the plant is converted to hydrogen via a proton-exchange membrane (PEM) electrolyzer, hydrogen tanks are used for storage, and an additional turbine is added for hydrogen combustion. Continued work regarding this FORCE-DISPATCHES integration will include automatic generation of DISPATCHES models from HERON inputs, offering analysts the option of using either the RAVEN-runsRAVEN or DISPATCHES workflow to solve technoeconomic optimization problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic Storage Size Optimization for Electric Vehicle Extreme-Fast Charging Stations

En-route charging infrastructure for electric vehicles is critical to support transportation needs. These charging stations are likely to have high loads and especially sharp peak loads given fast charging capabilities needed to meet transportation schedules. In order to reduce both strain on distribution grid infrastructure and charging station operational costs, many stations are likely to employ behind the meter storage. This paper demonstrates a behind the meter storage sizing optimization that employs an open-source agent-based vehicle behavior model (BEAM) to determine the best sizing across many scenarios. This optimization and analysis is novel in that it examines how storage size impacts not only charging station cost and peak load, but also vehicle queue times. The optimization is also applied across a wide analysis region with sufficient diversity and numbers to provide novel statistical analysis of optimal sizes.

Aka, Julius↗

Sensor Placement Optimization Software Applied to Site-Scale Methane-Emissions Monitoring

Advances in sensor technology have increased our ability to monitor a wide range of environments. However, even as the cost of sensors decline, only a limited number of sensors can be installed at any given site. The physical placement of sensors, along with the sensor technology and operating conditions, can have a large impact on our ability to adequately monitor environmental change. This paper introduces a new open-source Python package, called Chama, that determines optimal sensor placement and technology to improve a sensor network’s detection capabilities. Additionally, the methods are demonstrated using site-specific methane emission scenarios that capture uncertainty in wind conditions and emission characteristics. Mixed-integer linear programming formulations are used to determine sensor locations and detection thresholds that maximize detection of the emission scenarios. The optimized sensor networks consistently increase the ability to detect leaks, as compared to sensors placed near each potential emission source or along the perimeter of the site.

47 OTHER INSTRUMENTATION↗

Simulation and Optimization of Volatile Fatty Acid Upgrading Strategies for Sustainable Transportation Fuel Production

Underutilized wet waste is a promising feedstock for production of carbon-neutral or carbon-negative liquid transportation fuels. Arrested methanogenesis of wet wastes by microbes, which produces mixtures of C2-C8 carboxylic acids (volatile fatty acids, VFAs), is practiced industrially at a pilot scale and the VFA products can be catalytically upgraded to molecules suitable for use as transportation fuels (alcohols and alkanes) via sequential ketonization and hydrogenation, both steps of which have been demonstrated with high (>90%) yield at the lab scale. We present in this work a simulation-based decision-making framework which evaluates upgrading strategies of VFAs to alcohol- and hydrocarbon-based neat and blended diesel, jet, and gasoline fuels. The processes utilize sequential upgrading steps (ketonization and hydrogenation) accompanied by one distillation step (either separating VFAs before ketonization or alcohols after ketone hydrogenation) to form two liquid streams: a light alcohol stream best suited as a light-duty fuel and a heavy alcohol or hydrocarbon stream best suited as a diesel or jet fuel. Suitability of the liquid products as transportation fuels and maximum blending levels with petrofuels comes from simulation of critical fuel properties (boiling point, flash point, lower heating value, viscosity, melting point, water solubility, and cetane/octane number). Catalytic upgrading steps and fuel property mixing models used by the simulation are experimentally validated. We demonstrate the flexibility of the decision-making algorithm by evaluating processing scenarios for experimentally-observed VFA profiles with varied carbon chain length distributions. Processing scenarios are optimized for either maximum total renewable carbon utilization or production of heavy-duty (jet or diesel) fuels. We evaluate the economic viability and CO2 emissions of each proposed upgrading scenario using techno-economic and life cycle analyses. The decision-making framework developed in this work can also be used to down-select promising strategies for upgrading of other bio-based feedstocks to sustainable fuels and chemicals.

aviation fuel↗

Integrated GW Farm ABM

This Data Repository includes data used for the integrated groundwater- farm ABM model, raw model output from scenario ensemble, and processed outputs that isolate the groundwater storage depletion outcomes for the 35,000 farm cells. Model Inputs: Farm ABM Inputs: This folder contains the input data used by the integrated groundwater - farm ABM modelling script (Python file) used for the high performance computing (HPC) experiments. The sub-folder "data inputs" contains all of the farm attribute data, while the three files in the folder have the hydrogeological data lookup table (NLDAS Cost Curve Attributes.csv), a lookup table (Theis well function table.csv) for the groundwater cost curve function, and the farm indexes and corresponding NLDAS ids for all of the cells run in this experiment (nldas farms subset final.csv). NLDAS Cost curve hydrogeological data: Hydrogeological data aggregated to 1/8 degree resolution and aligned with the NLDAS grid. Parameters include: water depth below ground surface [meters], subsurface porosity [unitless], aquifer depth from ground surface to aquifer bottom [meters], annual average recharge (USGS: mm, Doll: meters), and three different hydraulic conductivity (K) values (meters/day). The three K values represent the mean value from Gleeson et al. (2018), one standard deviation above the mean from Gleeson et al. (2018), and the de Graaf et al. 2020 modifications to certain lithologies. Additional information about these datasets and their processing are documented in the supplement to Yoon et al. 2025 (in review). Output: Raw outputs: This folder contains a .zip file that has model outputs for the entire scenario ensemble. There is one csv for each farm id, using the format "farm farmid cases.csv". The relationship between the farm id and NLDAS id is defined by the "nldas farms subset final.csv" located in the Farm ABM Inputs folder. Each csv has 625 rows, corresponding to 625 combinations of different scenario parameter values. Each row (scenario) represents the outcome of a 100 year simulation. Columns define scenario settings and summary statistics for each scenario. The first four columns define the scenario settings: "hydro ratio," "econ ratio," "K scenario," and "gamma scenario." The hydro and econ ratios are values passed to the modeling script that influence multipliers for other model parameters, as documented in the supplement to Yoon et al. 2025 (in review). The gamma multiplier is a coefficient multiplier applied to the baseline gamma values (values below 1 represent lower unobserved costs compared to baseline, values above 1 represent higher costs). The K scenario names represent K values of: "low": 0.5 m/d, "int 1": 2.5 m/d, "int 2": 10 m/d, "high": 50 m/d, and "gleeson": mean Gleeson K value. "Perc vol depleted" is the fraction of groundwater depleted at the end of the 100 simulation. Processed Output: Derived depletion outcomes from raw outputs: All of the individual csv files from the Raw outputs were aggregated into a single file that has the scenario settings and fraction depletion "Perc vol depleted" for every farm cell, for every scenario. The other two files define relationships between the farm id, NLDAS id, and local and major aquifer units, used for aquifer-level depletion analysis.

Agent based modeling↗

Optimal Renewable Resource Allocation and Load Scheduling of Resilient Communities

This paper presents a methodology for enhancing community resilience through optimal renewable resource allocation and load scheduling in order to minimize unserved load and thermal discomfort. The proposed control architecture distributes the computational effort and is easier to be scaled up than traditional centralized control. The decentralized control architecture consists of two layers: The community operator layer (COL) allocates the limited amount of renewable energy resource according to the power flexibility of each building. The building agent layer (BAL) addresses the optimal load scheduling problem for each building with the allowable load determined by the COL. Both layers are formulated as a model predictive control (MPC) based optimization. Simulation scenarios are designed to compare different combinations of building weighting methods and objective functions to provide guidance for real-world deployment by community and microgrid operators. The results indicate that the impact of power flexibility is more prominent than the weighting factor to the resource allocation process. Allocation based purely on occupancy status could lead to an increase of PV curtailment. Further, it is necessary for the building agent to have multi-objective optimization to minimize unserved load ratio and maximize comfort simultaneously.

model predictive control↗