Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARABOLOIDAL MIRROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optical design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena at extreme-ultraviolet wavelengths

The design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena in the solar atmosphere at extreme ultraviolet (EUV) wavelengths is described. The normal-incidence spectrometer requires only one reflective surface, and is equipped with a series of exit slits and associated one-dimensional detector arrays that are mounted at the secondary (vertical) foci of the concave diffraction grating. It is shown that such a spectrometer mounted at the focus of an off-axis paraboloid telescope mirror of the size employed in the EUV spectroheliometer flown on Skylab could record monochromatic images of a 2 x 2 (arcmin) sq field-of-view with a spatial resolution element of 1 x 1 (arcsec) sq in a time of 4 s, 24 s, or 4 min, depending on whether the region studied is flaring, active, or quiet. The resulting spectroheliograms would have an average photometric precision of 10% and a spectral purity of 0.1 A.

Huber, M. C. E.↗

Thermal Compensator for Paraboloidal Reflector

Mounting structure holds off-axis paraboloidal collimating mirror so that optical axis constantly focused and remains stationary with respect to fixed point over wide temperature range.

Stanich, C. G.↗

Fabrication of imaging X-ray optics

The design, fabrication, and performance of optics for X-ray astronomy and laboratory applications are described and illustrated with diagrams, drawings, graphs, photographs, and sample images. Particular attention is given to the Wolter I telescope developed for spectroscopic observation of 8-30-A cosmic X-ray sources from a rocketborne X-ray Objective Grating Spectrometer; this instrument employs three nested paraboloid-hyperboloid mirrors of 5083 Al alloy, figured by diamond turning and covered with a thin coating of acrylic lacquer prior to deposition of a 40-nm-thick layer of Sn. In calibration tests at NASA Marshall, the FWHM of the line-spread function at 1.33 nm was found to be 240 microns, corresponding to 21 arcsec. Also presented are the results of reflectivity measurements on C and W multilayers sputtered on Si and fusion glass substrates.

Catura, R. C.↗

Two-Wavelength Optical-Path-Difference Mapping

Proposed technique for measuring shapes and alignments of reflectors based on use of two-wavelength absolute-distance interferometer to generate optical-path-difference maps of reflecting or refracting surfaces. Facilitates such tasks as determining manufacturing and alignment errors of off-axis segment of large-aperture paraboloidal telescope mirror, or aligning all segments of such mirror. Suitable for use where reflecting surfaces highly aspherical, initial misalignments large, and/or surface errors exceed optical wavelengths.

Manhart, Paul K.↗

Characteristics of a 60-Inch Arc-Image Furnace and Application to the Study of Materials

An arc-image furnace consisting of two paraboloidal searchlight mirrors 60 inches (152 centimeters) in diameter and a modified electrode mechanism has been developed and has been used as an operational piece of laboratory equipment for the study of the elevated-temperature behavior of engineering materials. Using two types of 16-millimeter high-current anodes and operating in the atmosphere at current levels of 80 to 550 amperes, the arc-image furnace provides a heating-rate range from 100 to 1,000 Btu per square foot-sec (27 to 270 cal per centimeters squared-sec) with good reliability and reproducibility. Running times vary from 60 seconds at 550 amperes to 10 minute or longer at the lower current levels.

Peters, Roger W.↗

Development and Validation of Low-Cost, High-Reflectance Composite CSP Facets: SIPS Final Report

This work investigates the various challenges associated with developing heliostat structural composite facets using 1 mm glass mirrors. Such facets are desirable for Concentrating Solar Power because 1 mm glass mirrors provide an absolute increase in reflectivity of 2-3 % over the industry standard of 4 mm glass mirrors. Prototypes of paraboloid composite facets with 1 mm glass mirrors were constructed that have a root mean square slope error on the order of 2 mrad while achieving greater than 96% reflectivity. These facets were constructed using a low-quality aluminum mold and a bill of materials that show potential to achieve cost parity with existing 4 mm glass mirrors supported by structural steel. The facets produced were able to survive up to 50 mm hail ball impacts and were robust against accelerated environmental cycling designed to expose durability concerns. Further work is needed to develop a scalable and cost-effective manufacturing process with a similar bill of materials.

14 SOLAR ENERGY↗

Progress on the Fabrication of High Resolution and Lightweight Monocrystalline Silicon X-ray Mirrors

Monocrystalline silicon is an excellent X-ray mirror substrate material due to its high stiffness, low density, high thermal conductivity, zero internal stress, and commercial availability. Our work at NASA Goddard Space Flight Center focuses on identifying and developing a manufacturing process to produce high resolution and lightweight X-ray mirror segments in a cost and time effective manner. Previous efforts focused on demonstrating the feasibility of cylindrical silicon mirror polishing and lightweighting. Present efforts are aimed towards producing true paraboloidal and hyperboloidal mirror surfaces on the lightweight silicon segments. This paper presents results from these recent investigations, including a mirror which features a surface quality sufficient for a 3 arcsecond telescope.

X-ray optics↗

Development Status of Adjustable X-Ray Optics with 0.5 Arcsecond Resolution

We report on the continuing development of adjustable, grazing incidence X-ray optics for 0.5 arcsec telescopes. Adjustable X-ray optics offer the potential for achieving sub-arcsecond imaging resolution while sufficiently thin and light-weight to constitute a mirror assembly with several square meters collecting area. The adjustable mirror concept employs a continuous thin film of piezoelectric material deposited on the back of the paraboloid and hyperboloid mirror segments. Individually addressable electrodes on the piezoelectric layer allow the introduction of deformations in localized "cells" which are used to correct mirror figure errors resulting from fabrication, mounting and aligning the thin mirrors, residual gravity release and temperature changes. We describe recent results of this development. These include improving cell yield to approx. 100 per cent, measurements of hysteresis and stability, comparisons of modeled and measured behavior, simulations of mirror performance, and the development and testing of conical Wolter- I mirror segments. We also present our plans going forward toward the eventual goal of achieving TRL 6 prior to the 2020 Decadal Review.

Reid, P. B.↗

Optical design of the ATMOS Fourier transform spectrometer

The optical system design of the ATMOS Fourier transform spectrometer to be operated from Spacelab for the measurement of stratospheric trace molecules is described. The design contains features which can achieve the required fringe contrast of 80% and spectral resolution of 0.02/cm over a spectral range of 2-16 microns. In particular, the design is based on the following features which alleviate the usual requirements for alignment precision: (1) 'cat's eye' mirror configuration in the two arms of the interferometer for retroreflection stability, (2) tilt-compensated system of beamsplitter, compensator, and fold mirrors for wavefront directional stability, (3) paraboloidal 'cat's eye' primary mirror for wavefront stability against shear, (4) rotatable compensator for matching chromatic dispersion, and (5) wedged refractive components to avoid channel spectra due to the Fabry-Perot effect.

Abel, I. R.↗

Out-of-Focus Alinement of Solar Concentrators

In new alinement technique, no attempt made to simulate infinitely distant light source, and all mirrors left uncovered throughout procedure. Light source placed at distance of 1,650 feet (503 m); other distances used. Alinement of approximately 250 mirror facets of paraboloidal solar concentrator simplified by precalculated images reflected from all facets. Developed for large solar concentrators, technique used with other multiplemirror or multiple-light-source systems for producing specified illuminance patterns.

Argoud, M. J.↗

On the Development of the Marshall Grazing Incidence X-ray Spectrograph (MaGIXS) Mirrors

The Marshall Grazing Incidence X-ray Spectrograph (MaGIXS) is a sounding rocket experiment that will obtain spatially resolved soft X-ray spectra of the solar corona from 0.5 - 2 keV. The optical system comprises a Wolter-I telescope mirror, a slit spectrograph, and a CCD camera. The spectrograph has a finite conjugate paraboloid pair, which re-images the slit, and a varied line-space planar reflection grating. Both the Wolter-I mirror and paraboloid pair are being fabricated at the NASA Marshall Space Flight Center (MSFC), using nickel replication. The MaGIXS mirror mandrels have been diamond turned, polished, and have yielded a set of engineering mirrors. Unlike other grazing incidence instruments, such as FOXSI, ART-XC, and IXPE, the MaGIXS prescriptions have large departure from a cone. This property exacerbates challenges with conventional lap polishing techniques and interferometric metrology. Here we discuss the progression of the optical surfaces of the mandrels through lap polishing, X-ray data from the replicated shells obtained in the MSFC Stray Light Facility (SLF), and our transition to using the ZEEKO computer numerical controlled (CNC) polisher for figure correction.

Champey, Patrick↗

A Q-band frequency tunable Doppler backscattering (DBS) system for pedestal and scrape-off layer density fluctuation and flow measurements in the DIII-D tokamak

We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.

Instruments & Instrumentation↗

Compact Concentrators for Solar Cells

Each cell in array has own concentrator. A Cassegrain Reflector combination of paraboloidal and hyperboloidar mirrors-used with conical reflector at each element of array. Three components direct light to small solar cell. No cooling fins, fans, pumps, or heat pipes needed, not even in vacuum.

Whang, V. S.↗

Polarization analysis of the Advanced X-ray Astrophysical Facility telescope assembly

The Advanced X-ray Astrophysical Facility (AXAF) telescope consists of six concentric paraboloid-hyperboloid pairs of mirrors operating near grazing incidence. Because of the substantial polarization effects at large angles of incidence, there is concern about the feasibility of polarimetry near the focal plane. The primary mirror acts as a tangentially directed half-wave linear retarder and nearly completely depolarizes the linearly polarized component of the light. The secondary mirror introduces an additional half wave of linear retardance. The tangentially directed one-wave linear retarder leaves the transmitted beam in the incident polarization state. The net instrumental polarization effects are small, and polarimetry is feasible with the AXAF.

Brown, Daniel M.↗

Polarization aberration analysis of the Advanced X-ray Astrophysics Facility Telescope assembly

The Advanced X-ray Astrophysics Facility (AXAF) Telescope consists of six concentric paraboloid-hyperboloid pairs of mirrors that operate near grazing incidence. Because of the substantial polarization effects at large angles of incidence there has been concern regarding the feasibility of doing polarimetry near the telescope focal plane. The primary mirror is here shown to act as a tangentially directed half-wave linear retarder and almost completely to depolarize the linearly polarized component of the light. The secondary mirror introduces and additional half-wave of linear retardance. The two-mirror telescope assembly acts as a tangentially directed one-wave linear retarder. Each mirror depolarizes alone but together the two-mirror assembly preserves the polarization state. The net instrumental polarization effects are small and polarimetry is feasible with AXAF.

Chipman, Russell A.↗