Direct strain correlations at the single-atom level in three-dimensional core-shell interface structures

Abstract Nanomaterials with core-shell architectures are prominent examples of strain-engineered materials. The lattice mismatch between the core and shell materials can cause strong interface strain, which affects the surface structures. Therefore, surface functional properties such as catalytic activities can be designed by fine-tuning the misfit strain at the interface. To precisely control the core-shell effect, it is essential to understand how the surface and interface strains are related at the atomic scale. Here, we elucidate the surface-interface strain relations by determining the full 3D atomic structure of Pd@Pt core-shell nanoparticles at the single-atom level via atomic electron tomography. Full 3D displacement fields and strain profiles of core-shell nanoparticles were obtained, which revealed a direct correlation between the surface and interface strain. The strain distributions show a strong shape-dependent anisotropy, whose nature was further corroborated by molecular statics simulations. From the observed surface strains, the surface oxygen reduction reaction activities were predicted. These findings give a deep understanding of structure-property relationships in strain-engineerable core-shell systems, which can lead to direct control over the resulting catalytic properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain-insensitive intrinsically stretchable transistors and circuits

An all-elastomer strain engineering approach, which uses patterned elastomer layers with tunable stiffnesses, can be used to create intrinsically stretchable transistor arrays with a device density of 340 transistors cm -2 and strain insensitivity of less than 5% performance variation when stretched to 100% strain. Intrinsically stretchable electronics can form intimate interfaces with the human body, creating devices that could be used to monitor physiological signals without constraining movement. However, mechanical strain invariably leads to the degradation of the electronic properties of the devices. Here we show that strain-insensitive intrinsically stretchable transistor arrays can be created using an all-elastomer strain engineering approach, in which the patterned elastomer layers with tunable stiffnesses are incorporated into the transistor structure. By varying the cross-linking density of the elastomers, areas of increased local stiffness are introduced, reducing strain on the active regions of the devices. This approach can be readily incorporated into existing fabrication processes, and we use it to create arrays with a device density of 340 transistors cm -2 and a strain insensitivity of less than 5% performance variation when stretched to 100% strain. We also show that it can be used to fabricate strain-insensitive circuit elements, including NOR gates, ring oscillators and high-gain amplifiers for the stable monitoring of electrophysiological signals.

42 ENGINEERING↗

Enabling room-temperature ferromagnetism in few-layered MoS 2 films via strain engineering

Strain engineering presents a promising pathway for modulating the physical properties of two-dimensional (2D) transition metal dichalcogenides materials. Here, in this study, we investigate the strain-induced magnetic behavior of diamagnetic MoS 2 films prepared by the DC magnetron sputtering technique. By applying +1% tensile strain to few-layered MoS 2 films (∼3.5 nm), we observe the emergence of room-temperature ferromagnetism with a magnetization saturation of about ∼130 emu/cm 3 , in stark contrast to bulk films (∼40 nm), which remain diamagnetic under similar conditions. Raman spectroscopy reveals a pronounced reduction in the intensity and the splitting of the E′ mode in 1% strained few-layered films, indicating a possible bond elongation and symmetry breaking under tensile stress. Additionally, x-ray absorption spectroscopy at the Mo M 3 edge further confirms a strain-induced electronic structure modification in few-layered films, with no corresponding shift observed in bulk counterparts. Moreover, the strain-induced magnetic and structural changes are largely reversible upon strain release. We attribute the origin of ferromagnetism in few-layered films to the combined influence of tensile strain and defect-assisted bond weakening, which facilitates crystal field transitions within the Mo 4d orbitals. These findings demonstrate that strain engineering can effectively induce and modulate magnetism in 2D materials, providing opportunities for developing strain-controlled spintronic applications.

36 MATERIALS SCIENCE↗

Influence of quantum confinement and strain on orbital polarization of four-layer LaNiO 3 superlattices: A DFT+DMFT study

Atomically precise superlattices involving transition metal oxides provide a unique opportunity to engineer correlated electron physics using strain (modulated by choice of substate) and quantum confinement (controlled by layer thickness). We use the combination of density functional theory and dynamical mean field theory (DFT+DMFT) to study Ni E g d-orbital polarization in strained LaNiO 3 /LaAlO 3 superlattices consisting of four layers of nominally metallic NiO 2 and four layers of insulating AlO 2 separated by LaO layers. The layer-resolved orbital polarization is calculated as a function of strain and analyzed in terms of structural, quantum confinement, and correlation effects. We determined that the effect of strain is from the dependence of the results on the Ni-O bondlength ratio and the octahedral rotation angles; quantum confinement is studied by comparison to bulk calculations with similar degrees of strain; correlation effects are inferred by varying interaction parameters within our DFT+DMFT calculations. The calculated dependence of orbital polarization on strain in superlattices is qualitatively consistent with recent X-ray absorption spectroscopy and resonant reflectometry data. But, interesting differences of detail are found between theory and experiment. Under tensile strain, the two inequivalent Ni ions display orbital polarization similar to that calculated for strained bulk LaNiO 3 and observed in experiment. Compressive strain produces a larger dependence of orbital polarization on Ni position and even the inner Ni layer exhibits orbital polarization different from that calculated for strained bulk LaNiO 3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transcriptomic Analyses Elucidate Adaptive Differences of Closely Related Strains of Pseudomonas aeruginosa in Fuel

Pseudomonas aeruginosa can utilize hydrocarbons, but different strains have various degrees of adaptation despite their highly conserved genome. P. aeruginosa ATCC 33988 is highly adapted to hydrocarbons, while P. aeruginosa strain PAO1, a human pathogen, is less adapted and degrades jet fuel at a lower rate than does ATCC 33988. We investigated fuel-specific transcriptomic differences between these strains in order to ascertain the underlying mechanisms utilized by the adapted strain to proliferate in fuel. During growth in fuel, the genes related to alkane degradation, heat shock response, membrane proteins, efflux pumps, and several novel genes were upregulated in ATCC 33988. Overexpression of alk genes in PAO1 provided some improvement in growth, but it was not as robust as that of ATCC 33988, suggesting the role of other genes in adaptation. Expression of the function unknown gene PA5359 from ATCC 33988 in PAO1 increased the growth in fuel. Bioinformatic analysis revealed that PA5359 is a predicted lipoprotein with a conserved Yx(FWY)xxD motif, which is shared among bacterial adhesins. Overexpression of the putative resistance-nodulation-division (RND) efflux pump PA3521 to PA3523 increased the growth of the ATCC 33988 strain, suggesting a possible role in fuel tolerance. Interestingly, the PAO1 strain cannot utilize n -C 8 and n -C 10 . The expression of green fluorescent protein (GFP) under the control of alkB promoters confirmed that alk gene promoter polymorphism affects the expression of alk genes. Promoter fusion assays further confirmed that the regulation of alk genes was different in the two strains. Protein sequence analysis showed low amino acid differences for many of the upregulated genes, further supporting transcriptional control as the main mechanism for enhanced adaptation. Lastly, these results support that specific signal transduction, gene regulation, and coordination of multiple biological responses are required to improve the survival, growth, and metabolism of fuel in adapted strains. This study provides new insight into the mechanistic differences between strains and helpful information that may be applied in the improvement of bacterial strains for resistance to biotic and abiotic factors encountered during bioremediation and industrial biotechnological processes.

54 ENVIRONMENTAL SCIENCES↗

Improving a recombinant Zymomonas mobilis strain 8b through continuous adaptation on dilute acid pretreated corn stover hydrolysate

Complete conversion of the major sugars of biomass including both the C 5 and C 6 sugars is critical for biofuel production processes. Several inhibitory compounds like acetate, hydroxymethylfurfural (HMF), and furfural are produced from the biomass pretreatment process leading to ‘hydrolysate toxicity,’ a major problem for microorganisms to achieve complete sugar utilization. Therefore, development of more robust microorganisms to utilize the sugars released from biomass under toxic environment is critical. In this study, we use continuous culture methodologies to evolve and adapt the ethanologenic bacterium Zymomonas mobilis to improve its ethanol productivity using corn stover hydrolysate. The results are the following: A turbidostat was used to adapt the Z. mobilis strain 8b in the pretreated corn stover liquor. The adaptation was initiated using pure sugar (glucose and xylose) followed by feeding neutralized liquor at different dilution rates. Once the turbidostat reached 60% liquor content, the cells began washing out and the adaptation was stopped. Several ‘sub-strains’ were isolated, and one of them, SS3 (sub-strain 3), had 59% higher xylose utilization than the parent strain 8b when evaluated on 55% neutralized PCS (pretreated corn stover) liquor. Using saccharified PCS slurry generated by enzymatic hydrolysis from 25% solids loading, SS3 generated an ethanol yield of 75.5% compared to 64% for parent strain 8b. Furthermore, the total xylose utilization was 57.7% for SS3 versus 27.4% for strain 8b. To determine the underlying genotypes in these new sub-strains, we conducted genomic resequencing and identified numerous single-nucleotide mutations (SNPs) that had arisen in SS3. We further performed quantitative reverse transcription PCR (qRT-PCR) on genes potentially affected by these SNPs and identified significant down-regulation of two genes, ZMO0153 and ZMO0776, in SS3 suggesting potential genetic mechanisms behind SS3’s improved performance. In conclusion, we have adapted/evolved Z. mobilis strain 8b for enhanced tolerance to the toxic compounds present in corn stover hydrolysates. The adapted strain SS3 has higher xylose utilization rate and produce more ethanol than the parent strain. We have identified transcriptional changes which may be responsible for these phenotypes, providing foundations for future research directions in improving Z. mobilis as biocatalysts for the production of ethanol or other fuel precursors.

09 BIOMASS FUELS↗

Whole Genome Sequence Analysis Using JSpecies Tool Establishes Clonal Relationships between Listeria monocytogenes Strains from Epidemiologically Unrelated Listeriosis Outbreaks

In an effort to build a comprehensive genomic approach to food safety challenges, the FDA has implemented a whole genome sequencing effort, GenomeTrakr, which involves the sequencing and analysis of genomes of foodborne pathogens. As a part of this effort, we routinely sequence whole genomes of Listeria monocytogenes (Lm) isolates associated with human listeriosis outbreaks, as well as those isolated through other sources. To rapidly establish genetic relatedness of these genomes, we evaluated tetranucleotide frequency analysis via the JSpecies program to provide a cursory analysis of strain relatedness. The JSpecies tetranucleotide (tetra) analysis plots standardized (z-score) tetramer word frequencies of two strains against each other and uses linear regression analysis to determine similarity (r 2 ). This tool was able to validate the close relationships between outbreak related strains from four different outbreaks. Included in this study was the analysis of Lm strains isolated during the recent caramel apple outbreak and stone fruit incident in 2014. We identified that many of the isolates from these two outbreaks shared a common 4b variant (4bV) serotype, also designated as IVb-v1, using a qPCR protocol developed in our laboratory. The 4bV serotype is characterized by the presence of a 6.3 Kb DNA segment normally found in serotype 1/2a, 3a, 1/2c and 3c strains but not in serotype 4b or 1/2b strains. We decided to compare these strains at a genomic level using the JSpecies Tetra tool. Specifically, we compared several 4bV and 4b isolates and identified a high level of similarity between the stone fruit and apple 4bV strains, but not the 4b strains co-identified in the caramel apple outbreak or other 4b or 4bV strains in our collection. This finding was further substantiated by a SNP-based analysis. Additionally, we were able to identify close relatedness between isolates from clinical cases from 1993–1994 and a single case from 2011 as well as links between two isolates from over 30 years ago. The identification of these potential links shows that JSpecies Tetra analysis can be a useful tool in rapidly assessing genetic relatedness of Lm isolates during outbreak investigations and for comparing historical isolates. In conclusion, our analyses led to the identification of a highly related clonal group involved in two separate outbreaks, stone fruit and caramel apple, and suggests the possibility of a new genotype that may be better adapted for certain foods and/or environment.

59 BASIC BIOLOGICAL SCIENCES↗

Crustal Strain Rates in the Western United States and Their Relationship with Earthquake Rates

Abstract We present a suite of strain rate models for the western United States based on geologic and geodetic data. The geologic data consist of Quaternary fault-slip rates and the geodetic data consists of a new compilation of Global Positioning System (GPS) velocities derived from continuous, semicontinuous, and campaign measurements. We remove postseismic deformation from the GPS time series in order for our geodetic strain rate model to best capture the interseismic strain accumulation rate. We present models based on either geologic or geodetic data, but also create a hybrid model. Although there are some differences between the models, the large-scale features are the same, with the noticeable exception for the Pacific Northwest where interseismic strain is naturally more distributed than the long-term strain release. We also present a map of earthquake rate densities based on mainshocks, and the result has similar spatial features similar to the strain rate models (at least in the southwestern United States). We perform a general correlation analysis between strain rate and seismicity rate (south of Cascadia) and find a change in linearity between seismicity and strain rates from slow to faster deforming areas with seismicity rates relatively lower for the latter. The extent of that change depends a bit on assumptions made on the declustering and completeness of the catalog, but the finding of a change in slope is robust across the different strain rate models. Linearity for all areas is only expected when Gutenberg–Richter parameters and parameters involved in the conversion from strain to moment rate are uniform across the study area. We discuss these qualifications, but find no single satisfactory explanation for our observation. Moreover, when considering a rather short time and space, theoretical considerations of sampling from a power-law distribution actually predict there to be a power law instead of a linear relationship, generally consistent with our observation.

Geochemistry & Geophysics↗

Experimental Investigation of Low-Frequency Distributed Acoustic Strain-Rate Responses to Propagating Fractures

Summary Low-frequency distributed acoustic sensing (LF-DAS) responds to strain changes due to far-field fracture propagation. To better understand the LF-DAS response to fracture propagation, we performed laboratory-scale hydraulic fracture experiments with embedded optical strain sensors. The objectives of this research are to generate hydraulic fractures of known geometry, measure the strain response along the embedded fiber-optic cable comparable to LF-DAS measurements, and use the results to inform the interpretation of field-derived LF-DAS data. The experiments were conducted in unconfined transparent cubic blocks with a dimension of 8 in. on each side. The block was made of transparent epoxy to visualize the fracture propagation. Fiber-optic sensing cables were embedded in the block at different distances to the source of injection. We injected dyed water through an injection tubing to generate a transverse, radial fracture along an initial flaw. An optical interrogator recorded the response of offset fiber Bragg grating (FBG) strain sensors normal to the plane of the fracture. The strain data were visualized on a waterfall plot, akin to visualizations of field-derived LF-DAS data. Dimensional analysis was used to scale the laboratory results to field conditions. We compared the evolution of the strain response at the fiber-optic cable, injection pressure, and rate with known fracture geometry. The measured strains were compared with Sneddon’s (1946) linear elastic solution for a penny-shaped crack and found to follow this behavior. The generated radial fractures in transparent media can be modeled with Sneddon’s linear elastic radial fracture model and a Mode I critical stress intensity factor. The LF-DAS characteristic response of a narrowing region of extension surrounded by compression was exhibited as a fracture that approached and intersected the fiber-optic cable. The experimentally derived strain and strain-rate waterfall plots with known fracture geometry, injection rate, and pressure response provide insight in understanding LF-DAS responses in the field. Furthermore, we developed a method to estimate fracture geometry evolution from the fiber-optic strain data and validated the method against the experimental data.

Engineering↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

Genome sequence of Phaeobacter inhibens type strain (T5 T ), a secondary metabolite producing representative of the marine Roseobacter clade, and emendation of the species description of Phaeobacter inhibens

Strain T5 T is the type strain of the species Phaeobacter inhibens Martens et al. 2006, a secondary metabolite producing bacterium affiliated to the Roseobacter clade. Strain T5 T was isolated from a water sample taken at the German Wadden Sea, southern North Sea. Here we describe the complete genome sequence and annotation of this bacterium with a special focus on the secondary metabolism and compare it with the genomes of the Phaeobacter inhibens strains DSM 17395 and DSM 24588 (2.10), selected because of the close phylogenetic relationship based on the 16S rRNA gene sequences of these three strains. The genome of strain T5 T comprises 4,130,897 bp with 3.923 protein-coding genes and shows high similarities in genetic and genomic characteristics compared to P. inhibens DSM 17395 and DSM 24588 (2.10). Besides the chromosome, strain T5 T possesses four plasmids, three of which show a high similarity to the plasmids of the strains DSM 17395 and DSM 24588 (2.10). Analysis of the fourth plasmid suggested horizontal gene transfer. Most of the genes on this plasmid are not present in the strains DSM 17395 and DSM 24588 (2.10) including a nitrous oxide reductase, which allows strain T5 T a facultative anaerobic lifestyle. The G+C content was calculated from the genome sequence and differs significantly from the previously published value, thus warranting an emendation of the species description.

59 BASIC BIOLOGICAL SCIENCES↗

Nondestructive Measurement of Residual Strain in Connecting Rods Using Neutrons

Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this article consists of nondestructive residual strain measurements in the interior of connecting rods using the Second Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory (ORNL), measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of the connecting rod, which was prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however, the peak width can additionally be caused by microstresses and material dislocations.

36 MATERIALS SCIENCE↗

Non-Destructive Measurement of Residual Strain in Connecting Rods Using Neutrons

Increasing the strength of materials is effective in reducing weight and boosting structural part performance, but there are cases in where the residual strain generated during the process of manufacturing of high-strength materials results in a decline of durability. It is therefore important to understand how the residual strain in a manufactured component changes due to processing conditions. In the case of a connecting rod, because the strain load on the connecting rod rib sections is high, it is necessary to clearly understand the distribution of strain in the ribs. However, because residual strain is generally measured by using X-ray diffractometers or strain gauges, measurements are limited to the surface layer of the parts. Neutron beams, however, have a higher penetration depth than X-rays, allowing for strain measurement in the bulk material. The research discussed within this paper consists of non-destructive residual strain measurements in the interior of connecting rods using the 2nd Generation Neutron Residual Stress Mapping Facility (NRSF2) at Oak Ridge National Laboratory, measuring the Fe (211) diffraction peak position of the ferrite phase. The interior strain distribution of connecting rod, which prepared under different manufacturing processes, was revealed. By the visualization of interior strains, clear understandings of differences in various processing conditions were obtained. In addition, it is known that the peak width, which is also obtained during measurement, is suggestive of the size of crystallites in the structure; however the peak width can additionally be caused by microstresses and material dislocations.

Ikeda, Tomohiro↗

Testing of fiber composites at high strain rates

An experimental investigation was conducted to determine strain rate effects in fiber composites. Unidirectional composite specimens of boron/epoxy, graphite/epoxy, S-glass/epoxy and Kevlar/epoxy were tested at tensile strain rates of up to 27 m/m/sec. Longitudinal, transverse and in-plane shear properties, including modulus, Poisson's ratio, strength and ultimate strain, were determined by testing 0-, 90and 10-degree unidirectional coupons. Strains were measured by means of strain gages bonded on the coupons and loads were measured by means of a strain gage load cell. All specimens were loaded in an electrohydraulic loading system. The 0-degree properties which are governed by the fibers do not vary much with strain rate except for the Kevlar/epoxy material which shows an increase in both modulus and strength. The strain rate effects on 90-degree properties were small with a general trend toward higher strength with increasing strain rate. The most noticeable effect was on in-plane shear properties with shear strength values at high strain rates approximately fifteen percent higher than static values.

Daniel, I. M.↗

Two-dimensional high temperature strain measurement system

Two-dimensional optical strain measurements on high temperature test specimens are presented. This two-dimensional capability is implemented through a rotatable sensitive strain axis. Three components of surface strain can be measured automatically, from which the first and second principal strains are calculated. One- and two-dimensional strain measurements at temperatures beyond 750 C with a resolution of 15 microstrain are demonstrated. The system is based on a one-dimensional speckle shift technique. The speckle shift technique makes use of the linear relationship between surface strain and the differential shift of laser speckle patterns in the diffraction plane. Laser speckle is a phase effect that occurs when spatially coherent light interacts with an optically rough surface. Since speckle is generated by any diffusely reflecting surface, no specimen preparation is needed to obtain a good signal. Testing was done at room temperature on a flat specimen of Inconel 600 mounted in a fatigue testing machine. A load cell measured the stress on the specimen before and after acquiring the speckle data. Strain components were measured at 0 C (parallel to the load axis) and at plus or minus 45 C, and plots indicate the calculated values of the first and second principal strains. The measured values of Young's modulus and Poisson's ratio are in good agreement with handbook values. Good linearity of the principal strain moduli at high temperatures indicate precision and stability of the system. However, a systematic error in the high-temperature test setup introduced a scale factor in the slopes of the two-dimensional stress-strain curves. No high temperature effects, however, have been observed to degrade speckle correlation.

Lant, Christian T.↗

High-temperature strain measurement techniques: Current developments and challenges

Since 1987, a very substantial amount of R&D has been conducted in an attempt to develop reliable strain sensors for the measurements of structural strains during ground testing and hypersonic flight, at temperatures up to at least 2000 deg F. Much of the effort has been focused on requirements of the NASP Program. This presentation is limited to the current sensor development work and characterization studies carried out within that program. It is basically an assessment as to where we are now and what remains to be done in the way of technical accomplishments to meet the technical challenges posed by the requirements and constraints established for the NASP Program. The approach for meeting those requirements and constraints has been multi-disciplinary in nature. It was recognized early on that no one sensor could meet all these requirements and constraints, largely because of the large temperature range (cryogenic to at least 2000 deg F) and many other factors, including the most challenging requirement that the sensor system be capable of obtaining valid 'first cycle data'. Present candidate alloys for resistance-type strain gages include Fe-Cr-Al and Pd-Cr. Although they have superior properties regarding withstanding very high temperatures, they exhibit large apparent strains that must either be accounted for or cancelled out by various techniques, including the use of a dual-element, half-bridge dummy gage, or electrical compensation networks. A significant effort is being devoted to developing, refining, and evaluating the effectiveness of those techniques over a broad range in temperature and time. In the quest to obtain first-cycle data, ways must be found to eliminate the need to prestabilize or precondition the strain gage, before it is attached to the test article. It should be noted that present NASP constraints do not permit prestabilization of the sensor, in situ. Gages are currently being 'heat treated' during manufacture in both the wire- and foil-type resistance strain gages, and evaluation is in progress. In addition, the 'gage-on-shim' concept is being revisited. That concept will permit heat treatment of the gage during manufacture, before attachment on the test article. Also, it may permit the individual calibration of each gage regarding gage factor and apparent strain. Candidate alloys for the NASP include titanium metal-matrix and carbon-carbon composites. Although those materials have very attractive properties at elevated temperatures in terms of strength and weight, they pose significant attachment problems. Methods for making reliable strain gage and thermocouple attachments to them are currently under development. Experience to date indicates that Rokide attachment of the sensor directly to the protective coating is easier than to the base material itself. However, interpreting strain data from gages attached in this way may prove difficult because of possible cracks in the coating that form 'islands' and the mobility of those 'islands'. It is concluded, therefore, that major technical challenges lie ahead as we proceed to meet the stringent strain sensor requirements and constraints of the NASP Program.

Lemcoe, M. M.↗

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Gregory, Otto J.↗

Ignition Delay Associated with a Strained Strip

Ignition processes associated with two adjacent fuel-oxidizer interferences bounding a strained fuel strip are explored here using single-step activation energy asymptotics. Calculations are made for constant as well as temporally decaying strain fields. There possible models of ignition are determined: one in which the two interfaces ignite independently as diffusion flames; one in which the two interfaces ignite dependently and in which ignition occurs to form a single , premixed flame at very high strain rates before ignition is completely prevented. In contrast to a single, isolated interface in which ignition can be prevented by overmatching heat production with heat convection due to strain, ignition of a strained fuel strip can also be prevented if the finite extend of fuel is diluted by oxidizer more quickly than heat production can cause a positive feedback thermal runaway. These behaviors are dependent on the relative sizes of timescales associated with species and heat diffusion, with convection due to strain, and with the chemical reaction. The result here indicate that adjacent, strained species interfaces may ignite quite differently in nature from ignition of a single, strained intrface and that their interdependence should be considered as the interfaces are brought closer together in complex strain fields. Critical strain rates leading to complete ignition delay are found to be considerably smaller for the fuel strip than those for single interfaces as the fuel strip is made thin in comparison to diffusion and chemical length scales.