Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

30 cm Drop Modeling

This report documents modeling and analysis of the 30 cm cask drop scenario for spent nuclear fuel (SNF) casks. The 30 cm drop is an important hypothetical dynamic loading scenario for SNF because 10 CFR 71.71 defines testing requirements for normal conditions of transport (NCT) of SNF packages, and free drop (of 30 cm for the heaviest packages) tests are required. Other NCT conditions specified in 10 CFR 71.71 include vibration normally incident to transport, and DOE’s multimodal transportation test (MMTT) and related analysis concluded that mechanical shock and vibration incident to transportation is negligible for SNF structural integrity because the loads are so small. The SNF cask 30 cm drop has a lot more potential to cause damage to SNF because the kinetic energy and momentum of the system is stopped abruptly during the cask impact event. Test data and model predictions both agree that the SNF assemblies are subjected to significantly higher loads in a cask drop event than normal transportation shock and vibration, but currently there is no reason to expect gross structural damage of the fuel assembly or widespread SNF cladding failure as a result of a 30 cm cask drop. The ultimate goal of this work is to close the knowledge gap of stress profiles on SNF rods and fuel assembly components during NCT, and this report describes the progress toward reaching that goal as well as a plan for finishing this work over the next year or two. Key remaining tasks include refining the fuel assembly model, calculating a selection of specific fuel assembly cases to populate the damage model, and finally running the damage model to predict the full general response range of 30 cm drop loads on SNF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact Testing and Analysis of Modified Metal Slugs

This report summarizes initial results from a series of gun experiments which were conducted at the DICE facility. The target of these experiments was a modified metal slug composed of a tantalum/tungsten alloy (Ta-10W). The general geometry of the slug was a right circular cylinder with a through-hole cut normal to the cylinder's axis. In all experiments, hardened steel impactors were used, the desired impact velocity was 200 m/s, the slug was preheated to a target temperature of 175° C, photon doppler velocimetry (PDV) was used to measure the projectile velocity before and after impact, and the impact event was recorded with high-speed video. In two of the impacts the slug was oriented perpendicular to the projectile, while in the remaining two it was tilted 8° from normal. Initial high-speed speed video results showed slug failure in the tilted impact case, while the slug survived normal impacts. Recovery fixtures were used to preserve impacted slugs for future postmortem analysis. Discussions are included regarding improvements to potential future experiments involving these slugs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stochastic Approaches for Calculating and Aggregating Detection Probabilities for Nuclear Material Diversion

The authors built and tested a stochastic simulation to estimate achieved detection probabilities (DPs) on a stratum basis, over a tailorable range of diverted amounts from 0 to 2 significant quantities (SQ), using typical International Atomic Energy Agency (IAEA) inspection data: i.e., SQ in stratum, number of items, number of gross/partial/bias defect measurements conducted, and realistic relative standard deviation (RSD) values for typical IAEA verification measurements. For bulk strata, the model calculates achieved DP at 0.01 SQ diversion increments; for item strata, the model calculates DP using the smallest realistic diversion increment (e.g., a plate, pin, or coupon). After successfully benchmarking against IAEA deterministic models, the simulation was used to test the sensitivity of DP to certain standard assumptions and selected input parameters. First, the equal defect assumption was tested; the results suggest significant complexity in the effectiveness of partial defect measurements. Next, the authors explored the sensitivity of DP to the assumed RSD of attribute tests. Then, the authors compared non-normal models for instrument performance (e.g., logistic, step, or arbitrary functions) to the typical results from a normal distribution (characterized by RSD). This last comparison was supplemented with experimentally derived performance data for an HM-5 gamma spectrometer. The HM-5 was used to make enrichment measurements on both LEU and HEU MTR fuel elements as plates were removed, and the results fit with logistic and step curves and applied in the simulation. These stochastic DP results were compared to DP estimates from a deterministic model assuming a normal curve and typical RSD, yielding insights that could improve effectiveness in the field. These early results illustrate the potential of stochastic models to better understand achieved DP and to improve safeguards effectiveness.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analysis of Approximations in Modeling of BWR Bundle Void Distributions

In boiling water reactors, complex heterogeneous bundle designs, control blades adjacent to the corner of bundles, and the presence of boiling can lead to complex internal void distributions. A few approximations exist to model these void distributions. They could be modeled using a 1D axial solver in which each axial node is assumed to be at an average void, or each pin cell could be modeled with its own void concentration. In the latter case, the void could be discretized in pin-centered or coolant-centered channels. The goal of this project was to quantify the effect of using the different approximations for modeling internal void distributions on neutronics calculations. Using 3D void distributions calculated with CTF, Monte Carlo Neutral Particle (MCNP) transport code models were created for GE-9 and GE-14 lattices. For each model, the internal void distribution from CTF at a given axial node was selected, and a lattice calculation was carried out with MCNP. Comparisons between models using a lattice-averaged void, or using a void distribution in coolant-centered channels, showed large differences in reactivity which in some cases were well above 1,000 pcm, and it also showed differences in normalized fission rates greater than 20%. It was also found that using a lattice average void can lead to a significant difference in the estimation of the worth of a control blade. The differences found when comparing results from models using pin-centered and coolant-centered channels were up to 200 pcm in reactivity and up to 1.4% in the normalized fission rates. In addition to these two sets of comparisons, MCNP models were set up so that each subchannel had a saturated liquid component around the fuel pins and a saturated vapor component in the center to approximate annular flow. In comparison to the models using coolant-centered subchannels, up to 1–3% differences in normalized fission rates could be found.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multispectral and Thermal Imager Onboard Aerial Platforms Instrument Handbook

The MicaSense Altum imager is an off-the-shelf, synchronized multispectral and thermal camera, combined with a Global Positioning System (GPS) unit and downwelling light sensor (DLS). The Altum takes images of the land surface within its field of view (FOV) across five visible bands and one longwave infrared thermal band. The sensor records the radiance and converts it to digital numbers. Imagery is radiometrically corrected, taking into account the sensor calibration, lens distortions, vignette effects, sun angle, and atmospheric effects (scattering and absorption). The photogrammetry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composite image using the technique of structure from motion image capture to construct a dense cloud and 3D model of the surface, which is used to produce a digital elevation model of the terrain surveyed and orthomosaic imagery. Land surface leaf area index, albedo, and surface skin temperature are provided for the user. The user can perform raster calculations on the imagery to produce various other vegetative indices, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). This code is provided with the readme file for each data set. The images have a resolution of 20-60 cm/pixel, which are subsampled to 100 cm/pixel.

47 OTHER INSTRUMENTATION↗

Bayesian Monte-Carlo Evaluation Framework for Imperfect Nuclear Data [Slides]

BMC evaluation is a tool used to address imperfect data and models, non-linear models, and non-normal PDFs. ENDF-6 format does not allow non-normal parameter PDFs. Storing posterior sets allows for variance, covariance, skewness, etc. To better predict criticality, we should document non-normal parameter PDFs (i.e. asymmetric uncertainty) and consider non-linear sensitivity of $k_{\text{eff}}$ to resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte-Carlo Framework: New Methods for Resonance Parameter Evaluation [Slides]

BMC evaluation is a tool to address imperfect data & models, non-linear models, and non-normal PDFs. ENDF-6 format does not allow non-normal parameter PDFs. Storing posterior sets allow for variance, covariance, skewness, etc. To better predict criticality, we could document non-normal parameter PDFs (i.e. asymmetric uncertainty), consider non-linear sensitivity of $\kappa$ eff to resonance parameters, and reduce uncertainty in key resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10-year period: The following decreasing trends were identified for TDPs for the most recent 10-year period: • Standby TDP FTR>1H failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands (demands per reactor year) • Normally running TDP frequency of run hours (hours per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multilayer Architecture Barriers for High Temperature Nuclear Applications

Innovative thin film multilayer metal/ceramic barrier coatings have been developed by Argonne National Laboratory to protect fuel cladding against different phenomena that can be encountered under the harsh operating conditions of advanced nuclear reactors. One phenomenon is Fuel-Cladding Chemical Interaction (FCCI), which can represent a challenge to the performance of steel-clad metallic fuels in sodium-cooled fast reactors (SFRs), especially when operating to high burnups at elevated cladding temperatures, and long fuel residence time. Another phenomenon is the corrosion of zirconium-based cladding under prototypic boiling water reactor (BWR) conditions and associated cladding during off normal conditions, including loss of coolant accidents (LOCA). This work provides details of the development and testing of a thin film (few microns) multilayer metal/ceramic (CrY/Y 2 O 3 ) coatings on steel cladding and its performance against FCCI. The coating architecture evolved through systematic mechanical testing, radiation tolerance assessments, and high-temperature diffusion studies from a preliminary multilayer concept to an optimized high-performance design. The optimized structure leverages stoichiometric Y 2 O 3 for its exceptional radiation stability, chemical inertness, and ultra-low fission product diffusivity (e.g., Ce diffusivity ~10 -20 m 2 /s in irradiated Y 2 O 3 at 650 °C). This is paired with ductile chromium-rich interlayers (Cr 95 Y 5 ), which significantly enhance fracture toughness and mechanical resilience. Design refinements, including increased ceramic layer thickness and optimized Cr–Y interlayer composition, eliminated fracture propagation and preserved coating integrity under extreme mechanical stress (>10× typical reactor conditions) and prolonged radiation exposure (~300 dpa). Those conditions are well beyond expected conditions during normal operations in SFR, and cover some of the transient conditions as well. In addition, the coating deposition was demonstrated to be applied uniformly to the inner surface of steel tubes representing prototypic SFR cladding. Another phenomenon under consideration in this work is the corrosion of zirconium-based cladding under prototypic boiling water reactor (BWR) conditions and associated off normal conditions including loss of coolant accident (LOCA). Another multilayer thin film coating is considered for mitigation of this phenomenon, where a coating of yttrium aluminum and yttrium aluminum ceramic/metal thin film coating. Preliminary results on the coating performance during high temperature thermal cycling (up to 1000 C) have shown promising performance of the coating. On-going optimization of the coating will continue in FY26.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transfer Learning for HVAC System Fault Detection

Faults in HVAC systems degrade thermal comfort and energy efficiency in buildings and have received significant attention from the research community, with data driven methods gaining in popularity. Yet the lack of labeled data, such as normal versus faulty operational status, has slowed the application of machine learning to HVAC systems. In addition, for any particular building, there may be an insufficient number of observed faults over a reasonable amount of time for training. To overcome these challenges, we present a transfer methodology for a novel Bayesian classifier designed to distinguish between normal operations and faulty operations. The key is to train this classifier on a building with a large amount of sensor and fault data (for example, via simulation or standard test data) then transfer the classifier to a new building using a small amount of normal operations data from the new building. We demonstrate a proof-of-concept for transferring a classifier between architecturally similar buildings in different climates and show few samples are required to maintain classification precision and recall.

transfer learning, Building HVAC, Bayesian framewo↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗