Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Morphology-Dependent Resonances of Spherical Droplets with Numerous Microscopic Inclusions

We use the recently extended superposition T-matrix method to study the behavior of a sharp Lorenz-Mie resonance upon filling a spherical micrometer-sized droplet with tens and hundreds of randomly positioned microscopic inclusions. We show that as the number of inclusions increases, the extinction cross-section peak and the sharp asymmetry-parameter minimum become suppressed, widen, and move toward smaller droplet size parameters, while ratios of diagonal elements of the scattering matrix exhibit sharp angular features indicative of a distinctly nonspherical particle. Our results highlight the limitedness of the concept of an effective refractive index of an inhomogeneous spherical particle.

resonance↗

Atomic Force Microscope Observation of Growth and Defects on As-Grown (111) 3C-SiC Mesa Surfaces

This paper presents experimental atomic force microscope (AFM) observations of the surface morphology of as-grown (111) silicon-face 3C-SiC mesa heterofilms. Wide variations in 3C surface step structure are observed as a function of film growth conditions and film defect content. The vast majority of as-grown 3C-SiC surfaces consisted of trains of single bilayer height (0.25 nm) steps. Macrostep formation (i.e., step-bunching) was rarely observed, and then only on mesa heterofilms with extended crystal defects. As supersaturation is lowered by decreasing precursor concentration, terrace nucleation on the top (111) surface becomes suppressed, sometimes enabling the formation of thin 3C-SiC film surfaces completely free of steps. For thicker films, propagation of steps inward from mesa edges is sometimes observed, suggesting that enlarging 3C mesa sidewall facets begin to play an increasingly important role in film growth. The AFM observation of stacking faults (SF's) and 0.25 nm Burgers vector screw component growth spirals on the as-grown surface of defective 3C films is reported.

Neudeck, Philip G.↗

Light Microsopy Module, International Space Station Premier Automated Microscope

The Light Microscopy Module (LMM) was launched to the International Space Station (ISS) in 2009 and began science operations in 2010. It continues to support Physical and Biological scientific research on ISS. During 2015, if all goes as planned, five experiments will be completed: [1] Advanced Colloids Experiments with a manual sample base -3 (ACE-M-3), [2] the Advanced Colloids Experiment with a Heated Base -1 (ACE-H-1), [3] (ACE-H-2), [4] the Advanced Plant Experiment -03 (APEX-03), and [5] the Microchannel Diffusion Experiment (MDE). Preliminary results, along with an overview of present and future LMM capabilities will be presented; this includes details on the planned data imaging processing and storage system, along with the confocal upgrade to the core microscope. [1] New York University: Paul Chaikin, Andrew Hollingsworth, and Stefano Sacanna, [2] University of Pennsylvania: Arjun Yodh and Matthew Gratale, [3] a consortium of universities from the State of Kentucky working through the Experimental Program to Stimulate Competitive Research (EPSCoR): Stuart Williams, Gerold Willing, Hemali Rathnayake, et al., [4] from the University of Florida and CASIS: Anna-Lisa Paul and Rob Ferl, and [5] from the Methodist Hospital Research Institute from CASIS: Alessandro Grattoni and Giancarlo Canavese.

Microscopy↗

Opportunity Microscopic Imager Results from the Western Rim of Endeavour Crater

The Athena science payload on the Mars Exploration Rovers (MER Spirit and Opportunity) includes the Microscopic Imager (MI), a fixed focus close-up camera mounted on the instrument arm. The MI acquires images at a scale of 31 micrometers/pixel over a broad spectral range (400 to 700 nm) using only natural illumination of target surfaces. Radio signals from Spirit have not been received since March 2010, so attempts to communicate with that rover ceased in mid-2011. The Opportunity MI optics were contaminated by a global dust storm in 2007. That contamination continues to reduce the contrast of MI images, and is being monitored by occasionally imaging the sky.

Herkenhoff, K. E.↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Unveiling the Mysteries of Mars with a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM)

Development of a miniaturized scanning electron microscope that will utilize the martian atmosphere to dissipate charge during analysis continues. This instrument is expected to be used on a future rover or lander to answer fundamental Mars science questions. To identify the most important questions, a survey was taken at the 47th Lunar and Planetary Science Conference (LPSC). From the gathered information initial topics were identified for a SEM on the martian surface. These priorities are identified and discussed below. Additionally, a concept of operations is provided with the goal of maximizing the science obtained with the minimum amount of communication with the instrument.

Lunar & Planetary Science & Exploration↗

Light Microscopy Module: International Space Station Premier Automated Microscope

The Light Microscopy Module (LMM) was launched to the International Space Station (ISS) in 2009 and began hardware operations in 2010. It continues to support Physical and Biological scientific research on ISS. During 2016, if all goes as planned, three experiments will be completed: [1] Advanced Colloids Experiments with Heated base-2 (ACE-H2) and [2] Advanced Colloids Experiments with Temperature control (ACE-T1). Preliminary results, along with an overview of present and future LMM capabilities will be presented; this includes details on the planned data imaging processing and storage system, along with the confocal upgrade to the core microscope. [1] a consortium of universities from the State of Kentucky working through the Experimental Program to Stimulate Competitive Research (EPSCoR): Stuart Williams, Gerold Willing, Hemali Rathnayake, et al. and [2] from Chungnam National University, Daejeon, S. Korea: Chang-Soo Lee, et al.

Microgravity Biology Research↗

Microscopes on ISS - Present and Future Possibilities

The attached slides are for an invited talk (invitation from Ken Savins at CASIS) to be given July 19 at the "2018 Microgravity Molecular Crystal Growth Workshop". Ken Savins indicated that the protein crystal growth community would benefit from knowing more about what is available on ISS for microscopy. It is especially important that the folks growing protein crystals start to use the microscopes on ISS as diagnostic tools so that when their samples are returned to Earth and the results are unexpected, they are able to determine whether or not the return flight had an impact. In additional to preparing this presentation describing present and possible future LMM capabilities (if it is refurbished), we worked with Rachel A Ormsby (techshot) and Devin Ridgley (HNu Photonics) to add slides and a movie they provided of their capacities. Contact information for the NASA GRC Liquid Crystal Facility (LCF) will be included, and a couple of slides for LCF may be added when the contractor (James Kolibas at ZIN Technology) returns from vacation.

protein crystals↗

Simulating Space Weathering in the Transmission Electron Microscope via Dynamic in Situ Heating and Helium Irradiation of Olivine

The chemical composition, microstructure, and optical properties of grains on the surfaces of airless bodies are predominantly altered by micrometeorite impacts and solar wind irradiation. These processes drive space weathering and result in the formation of features including chemically-altered, amorphous grain rims, Fe nanoparticles (npFe), and vesiculated grain textures. These characteristics have been identified in returned samples from the surfaces of the Moon and asteroid Itokawa. In order to advance our understanding of the formation of these microstructural and chemical features in returned samples, we have simulated space weathering processes for a variety of materials via laboratory experiments. These experiments include ion irradiation to simulate solar wind exposure and laser irradiation and in situ heating to simulate micrometeorite impacts. While these experiments have provided considerable insight into the formation mechanisms of many space weathering features, they are predominantly static and typically performed separately. Here we present results from the simulated space weathering of olivine grains via He irradiation and dynamic heating, both performed in situ inside the transmission electron microscope (TEM). These experiments allow for the real-time observation of chemical and microstructural changes resulting from the superposed effects of ion irradiation and pulsed heating.

Thompson, M. S.↗

Atomic-Scale Structure and Non-Stoichiometry of Meteoritic Hibonite: A Transmission Electron Microscope Study

Hibonite (CaAl_12O_19) is a common refractory mineral in Ca-Al-rich inclusions (CAIs) in primitive meteorites. Transmission electron microscope (TEM) studies have identified enigmatic planar defects in different occurrences of hibonite in the Allende meteorite that give rise to strong streaking along c* in electron diffraction patterns. Atomic resolution high-angle annular dark-field (HAADF) imaging and energy-dispersive X-ray (EDX) analyses were used to determine the nature and origin of these planar features. HAADF images of hibonite grains reveal lamellar intergrowths of common 1.6 nm spacing, and less commonly 2.0 and 2.5 nm spacings, interspersed in stoichiometric hibonite showing 1.1 nm (002) spacing. Stoichiometric hibonite consists of alternating Ca-containing (“R”) and spinel-structured (“S”) blocks stacked in a sequence RS. In contrast, the 1.6 nm layers result from a doubled S block such that the stacking sequence is RSS, while in the widest defect observed, the stacking sequence is RSSSS. These intergrowths are epitaxial and have coherent, low-strain boundaries with the host hibonite Meteoritic hibonite shows common Ti and Mg substitution for Al in its structure. Atomic-resolution EDX maps of hibonite grains in the Allende CAI confirm the preferred site occupancy of Mg on tetragonal M3 sites in S blocks and of Ti on trigonal bipyramidal M2 and octahedral M4 sites in R blocks. Mg is highly concentrated, but Ti is absent in the planar defects where wider S blocks show Al-rich compositions compared to stoichiometric MgAl_2O_4 spinel. Therefore, Mg likely played the major role in the formation and metastability of planar defects in hibonite. Electron energy loss spectroscopy data from the Ti L_2,3 edge show the presence of mixed Ti oxidation states with ~ 15–20% of Ti as Ti^(3+) in hibonite, suggesting a direct substitution of Ti^(3+) ↔ Al^(3+) in hibonite. The remaining ~ 80–85% of Ti is present as Ti^(4+) and corresponding EDX analyses are consistent with the well-known coupled substitution 2Al^(3+) ↔ Ti^(4+) + Mg^(2+) being the major mechanism for Ti and Mg substitution in hibonite. The formation of planar defects in hibonite occurred during high-temperature nebular condensation or melting/crystallization processes. The occurrence of non-stoichiometric hibonite in the Allende CAI deviates from the mineral formation sequence predicted from equilibrium condensation models. Overall, our atomic resolution TEM observations signify non-equilibrium, kinetic-controlled crystal growth during the high-temperature formation of refractory solids in the early solar nebula.

hibonite↗

Microscopic Object Classification through Passive Motion Observations with Holographic Microscopy

Digital holographic microscopy provides the ability to observe throughout a volume that is large compared to its resolution element without the need to refocus through the volume. This capability enables simultaneous observations of large numbers of small objects within such a volume. We have constructed a microscope that can observe a volume 0.4 x 0.4 x 1.0 µm with submicrometer resolution for observation of microorganisms and minerals in liquid environments in earth and on potential planetary missions. Because environmental samples are likely to contain mixtures of inorganics and microorganisms that are of comparable sizes near the resolution limit of the instrument, discrimination of living and non-living objects may be difficult. The motion of motile organisms can be used to readily distinguish them from non-motile objects (live or inorganic), but additional methods are required to distinguish non-motile organisms and inorganic objects that are of comparable size, but different composition and structure. In this paper we evaluate the use of passive motion to make this discrimination by evaluating diffusion and buoyancy characteristics of objects in the field of view.

Lindensmith, Christian↗

DHMx (Digital Holographic Microscope Experience) Software Tool

The DHMx (Digital Holographic Microscope Experience) is an open-source software suite designed to perform reconstructions from off-axis holograms obtained from either a real-time stream or from disk with a graphical interface for commanding and display

Fregoso, S. Felipe↗

A Cosmic Microscope for the Preheating Era

Light fields with spatially varying backgrounds can modulate cosmic preheating, and imprint the nonlinear effects of preheating dynamics at tiny scales on large scale fluctuations. This provides us a unique probe into the preheating era which we dub the “cosmic microscope”. We identify a distinctive effect of preheating on scalar perturbations that turns the Gaussian primordial fluctuations of a light scalar field into square waves, like a diode. The effect manifests itself as local non-Gaussianity. We present a model, “modulated partial preheating”, where this nonlinear effect is consistent with current observations and can be reached by near future cosmic probes.

Cosmology of Theories beyond the SM↗

Going to Extremes: Architecting Holographic Microscopes for Extreme Environments

Bacterial life exists on earth in extreme environments. These are environments described by large temperature excur- sions, large pressure excursions, and large radiation excursions from the nominal conditions near sea level which are largely populated by humans. These extreme locales represent such places as the ocean ice, the briny pools of Death Valley and deep mines, the acidic hot springs of the High Sierra or Yellowstone, or even the clouds of our upper atmosphere. The preponderance of bacterial life in these extreme environments here on earth suggests that bacterial life might likely exist in the extreme environments of our own solar system, such as the icy moons of Europa or Enceladus. Thus, architecting instruments for detect- ing life in these extreme environments on earth builds confidence that we can architect such instruments for flight missions. In this paper, we discuss our experience with designing digital holo- graphic microscope instruments to enable detection of bacteria in several extreme environments. In particular we discuss three different instruments. The first is our field instrument which is a small, portable instrument for examination of remote sites. The second is submersible instrument which enables exploration of deep aquatic environments and is deployed on a ocean-going drone. The third is a balloon-borne instrument to examine the bacterial content of the upper atmosphere. We will provide a review of each instrument and discuss aspects of instrument engineering for each particular application.

Ramirez, Alex↗

Design of a Low-Cost, Submersible, Digital Holographic Microscope for in Situ Microbial Imaging

The methodologies for studying marine microbiology typically consist of utilizing instrumentation within a laboratory. This typically requires extracting a sample from its place of origin prior to examination, which may be days after collection. Oftentimes, the solution is to bring the lab to the ocean, which may be costly and provide further limitations for a sterile and stable laboratory environment. Here we present a low-cost, submersible, digital holographic microscope (DHM) designed to image marine microorganisms (such as bacteria and plankton) in their natural underwater environment. Our instrument eliminates the need to transport samples and allows for instantaneous data collection of microbes in-situ. The DHM achieves sub-micron spatial resolution and is paired with artificial intelligence for the detection and tracking of specimens to reduce the overall collected data. This instrument also aims to reduce the cost of manufacturing and field expenses relative to marine microbiological research. “Off the shelf” components were selected in the design process of this instrument which allows us to achieve precise results without sacrificing data quality. The DHM itself costs under one thousand dollars and features a low-cost high-resolution camera, the Arducam MT9J001. Included in the design were five main subsystems: optical, mechanical, electrical, power, and machine learning. Our on board computer and artificial intelligence consist of a Raspberry Pi 4 (8 Gb) and Google Coral USB Tensorflow accelerator. Instrument testing has successfully proven our abilities of data acquisition for at least two hours in depths of at least forty meters below sea level. Additionally, our artificial intelligence system is currently capable of tracking up to ten areas of interest in a fraction of a second with over ninety percent confidence via the neural net driven by the tensor cores on the Google Coral. Furthermore, we have demonstrated the versatility of our instrument by mounting it on an ocean-going ROV, the BlueRov2 by BlueRobotics. Our tests on the BlueRov2 exemplified the cost-effective nature of a submersible and reusable instrument that can be implemented in moderate environments and on most vessels.

Wallace, James Kent↗

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

Truncated nonlinear interferometer-based atomic force microscopes

A truncated non-linear interferometer-based atomic force microscope (AFM) includes an input port and a non-linear amplifier that renders a probe beam and a conjugate beam. The AFM includes local oscillators having a relationship with the probe beam and the conjugate beam. The displacement of the AFM's cantilever is transduced by the probe beam, and/or the conjugate beam or their respective local oscillators. The AFM's phase-sensitive detectors detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. The detected phase modulation corresponds to the change in phase. The AFM's circuitry measures phase signals that are indicative of the cantilever displacement. The resulting measurement signals exhibit a quantum noise reduction in either the intensity difference or phase sum quadrature.

Pooser, Raphael C.↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗