Engineering PapersSearch

NASA NTRS · 20260006596

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

Abstract

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Keep this discovery

BibTeXRIS

Laura Wilson, Anthony Mosto, Evan Pineda, Brandon Hearley, Robert Wheeler. In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics. https://ntrs.nasa.gov/citations/20260006596

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Evaluating Crystallinity in Thermoplastic composites

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and manufacturing required in space. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are largely influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials reliably meet the high demands required by space exploration. This talk discusses the use of multiple techniques such as Polarized Light Optical Microscopy and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in various thermoplastic composites, including carbon fiber reinforced PMCs and novel bio-based Martian and Lunar regolith composites designed for in-situ manufacturing. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in space applications.

Thermoplastics

Evaluating Crystallinity in Thermoplastic Composites for Aerospace Applications

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and faster production. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are directly influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Within thermoplastic PMC parts, crystallinity gradients can arise due to variations in part geometry, across part thicknesses, and along bonded joints. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials meet the high demands required for aerospace. Several different analytical techniques exist that can be used to characterize the bulk crystallinity of thermoplastic materials. However, many existing methods lack the specificity required to identify the subtle variations in crystallinity that may play a significant role in the performance and durability of PMC parts. Because of this, a significant amount of work is still required to fully characterize and understand the crystallinity profiles of thermoplastic PMCs and the resulting impact to material properties. This talk discusses the use of multiple techniques such as Differential Scanning Calorimetry, Polarized Light Optical Microscopy, and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in carbon fiber/thermoplastic composites. Samples of different crystallinity profiles were manufactured using various cooling procedures. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in aerospace applications.

Thermoplastics

Mechanical Properties of Carbon Fiber Reinforced Composites Exposed to Cryogenic Conditions and Space Radiation via Simulation and Testing

As NASA missions extend beyond low Earth orbit, increasing reliance is placed on carbon fiber reinforced polymer (CFRP) composites for spacecraft structures where mass efficiency, durability, and long-term reliability are critical. In service, these materials are subjected to a combination of ultraviolet radiation, vacuum, ionizing radiation, atomic oxygen, and extreme thermal excursions under sustained mechanical loading. Flight systems such as the Boeing Starliner and SpaceX Dragon employ external composite structures that will experience these environments for extended durations. Although prior spaceflight and ground studies have reported limited changes in bulk mechanical properties, the synergistic effects of these environments on composite microstructure, particularly at the fiber matrix interphase, remain insufficiently characterized and represent a potential qualification and reliability risk. This study investigates the effects of short-term cryogenic exposure on a radiation shielding carbon epoxy composite, SC2020, as a ground-based analog for space relevant thermal extremes. The SC2020 material system has previously flown on the International Space Station under the Materials International Space Station Experiment (MISSE) program. Composite specimens were exposed to liquid nitrogen for 6 and 24 hours and evaluated using a multiscale characterization framework that combined ASTM D3039 tensile testing, Atomic Force Microscopy (AFM) based interphase analysis, and helium gas permeability measurements. Tensile testing showed no statistically significant or permanent degradation in global strength or modulus following cryogenic exposure. In contrast, AFM measurements revealed reductions in interphase modulus, weakened adhesion, and increased nanoscale heterogeneity, indicating localized degradation mechanisms not captured by conventional bulk testing. Gas permeability measurements showed a progressive increase in helium diffusion with exposure duration, consistent with micro-void formation or partial interfacial debonding. The results indicate that cryogenic exposure initiates degradation at the fiber matrix interphase while leaving global mechanical properties largely unchanged over short durations. These findings underscore the importance of multiscale diagnostics for identifying early-stage damage mechanisms that may influence long term performance and qualification margins for spaceflight composite structures. The data presented establish a cryogenic baseline for comparison with forthcoming MISSE flight exposure results and support ongoing NASA Established Program to Stimulate Competitive Research (EPSCoR) efforts aimed at improving composite qualification methodologies, risk assessment, and reliability prediction for space environments.

composite reliability