At least 415 records · Page 23

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Living anionic polymerization using a microfluidic reactor

Living anionic polymerizations were conducted within aluminum-polyimide microfluidic devices. Polymerizations of styrene in cyclohexane were carried out at various conditions, including elevated temperature (60 °C) and high monomer concentration (42%, by volume). The reactions were safely maintained at a controlled temperature at all points in the reactor. Conducting these reactions in a batch reactor results in uncontrolled heat generation with potentially dangerous rises in pressure. Moreover, the microfluidic nature of these devices allows for flexible 2D designing of the flow channel. Four flow designs were examined (straight, periodically pinched, obtuse zigzag, and acute zigzag channels). The ability to use the channel pattern to increase the level of mixing throughout the reactor was evaluated. When moderately high molecular mass polymers with increased viscosity were made, the patterned channels produced polymers with narrower PDI, indicating that passive mixing arising from the channel design is improving the reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlocal control of electron temperature in short direct current glow discharge plasma

To demonstrate controlling the electron temperature in nonlocal plasma, experiments have been performed on a short (without positive column) dc glow discharge with a cold cathode by applying different voltages to the conducting discharge wall. The experiments have been performed for low-pressure noble gas discharges. The applied voltage can modify trapping the energetic electrons emitted from the cathode sheath and arising from the atomic and molecular processes in the plasma within the device volume. This phenomenon results in the energetic electrons heating the slow plasma electrons, which consequently modifies the electron temperature. Furthermore, a numerical model of the discharge has demonstrated the electron temperature modification for the above case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental measurements and noise analysis of a cryogenic radiometer

A cryogenic radiometer device, intended for use as part of an electrical-substitution radiometer, was measured at low temperature. The device consists of a receiver cavity mechanically and thermally connected to a temperature-controlled stage through a thin-walled polyimide tube which serves as a weak thermal link. With the temperature difference between the receiver and the stage measured in millikelvin and the electrical power measured in picowatts, the measured responsivity was 4700 K/mW and the measured thermal time constant was 14 s at a stage temperature of 1.885 K. Noise analysis in terms of Noise Equivalent Power (NEP) was used to quantify the various fundamental and technical noise contributions, including phonon noise and Johnson-Nyquist noise. The noise analysis clarifies the path toward a cryogenic radiometer with a noise floor limited by fundamental phonon noise, where the magnitude of the phonon NEP is 6.5 fW/√(Hz) for the measured experimental parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Significant enhancement of magnetocaloric effect in a NiMnCuGa Heusler alloy through textural modification

Magnetocaloric materials are of increasing interest to bring magnetic refrigeration to everyday households and drastically impact the energy demands for temperature control devices. In this work, a polycrystalline Heusler alloy of composition Ni2Mn0.76Cu0.24Ga with coinciding structural and magnetic transformation temperatures was subjected to compressive stress assisted thermal cycling (SATC) to enhance the magnetic properties by inducing a preferred orientation in the martensite. Isofield magnetization measurements showed a sharpening of the transformation between ferromagnetic martensite and paramagnetic austenite due to SATC. In isothermal magnetization measurements, SATC was seen to increase the magnetostructural coupling. With a 2 T applied magnetic field, the magnetocaloric effect (MCE) increased from ∼10 to ∼25 J/kg K and the refrigeration capacity (RC) almost doubled due to SATC. Heat capacity measurements were largely unaffected by SATC. The change in adiabatic temperature was estimated by using Cp and change in magnetic entropy (ΔSM) calculations. SATC was seen to increase ΔTad from ∼1.2 K to 2 K for an applied magnetic field of 2 T. Neutron diffraction measurements revealed highly textured martensite in the as received state that rotated to a more ideal preferred orientation after SATC that enhanced the magnetostructural transformation; and thus, improving the MCE and ΔTad.

McLeod, M. V. (ORCID:0000000329883516)↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Scientific/Technical Report. A closed path methane and water vapor gas analyzer

Robust, economical, low-power and reliable closed-path methane (CH 4 ), carbon dioxide (CO 2 ), and water vapor (H 2 O) analyzers suitable for long-term measurements are not readily available commercially. Such analyzers are essential for quantifying the amount of CH 4 and CO 2 released from various ecosystems (wetlands, rice paddies, forests, etc.) and other surface contexts (e.g. landfills, animal husbandry lots, etc.), and for understanding the dynamics of the atmospheric CH4 and CO 2 budget and their impact on climate change and global warming. The purpose of this project is to develop a closed-path methane, carbon dioxide gas and water vapor analyzer capable of long-term measurements in remote areas for global climate change and environmental research. The analyzer will be capable of being deployed over a wide range of ecosystems to understand methane and carbon dioxide exchange between the atmosphere and the surface. Measurements of methane and carbon dioxide exchange need to be made all year-round with limited maintenance requirements. During this Phase II effort, we successfully completed the design of the electronics, optical bench, trace gas detection method and mechanical infrastructure. We are using the technologies of two vertical cavity surface emitting lasers, a multiple-pass Herriott optical cell, wavelength modulation spectroscopy and direct absorption to measure methane, carbon dioxide, and water vapor. We also have designed the instrument application software, Field Programmable Gate Array (FPGA), along with partial completion of the embedded software. The optical bench has been tested in a lab setting with very good results. Major sources of optical noise have been identified and through design, the optical noise floor is approaching -60dB. Both laser modules can be temperature controlled to help maximize the stability of the analyzer. Additionally, a piezo electric transducer has been utilized to randomize the noise introduced from potential etalons. It is expected that all original specifications contained within the initial proposal will be met. We are currently in the beginning stages of assembling the first generation prototypes and finalizing the remaining design elements. The first prototypes will initially be tested in our environmental calibration chamber in which specific gas concentrations, temperature and humidity levels can be controlled. Once operation in this controlled setting is verified, the prototypes will be deployed at LI-COR's Experimental Research Station (LERS). Deployment at the LERS site will test the instrument's robustness in a real-world situation.

47 OTHER INSTRUMENTATION↗

Mechanical Testing of TR-55 Rubber Thermally Aged Under Tensile Strain

TR-55 rubber specimens were previously subjected to an aging process consisting of the application of a tensile strain of approximately 67%, 100%, 133%, or 167% elongation for 4, 8, 12, or 16 h at either 250 C or room temperature. Control specimens at the same temperatures/durations were not subjected to tensile strain. The specimens were allowed to recover at room temperature without external stimuli for over 100 days before tensile testing. A single dog bone was cut from each specimen and a stress-strain curve was obtained. The elastic modulus of each specimen was calculated. Specimens aged under tensile strain exhibited rubber-like behavior dependent on the aging elongation and duration. This behavior was not evident in the unstrained controls. For the unstrained controls, exposure to 250 C resulted in an increase in modulus relative to the unheated material independent of the heating duration. The tensile strain applied during the aging process caused a reduction in modulus relative to the controls; lower moduli were observed for the shorter aging durations. Slippage of the specimens in the grips prevented determination of ultimate strength, as all specimens either slipped completely out of the grip before failure or failed at the original grip edge after slipping.

36 MATERIALS SCIENCE↗

Process control-enabled mitigation of microstructural and plastic heterogeneities in additively manufactured Grade 91 steel

Synergizing wire arc-directed energy deposition (WA-DED) additive manufacturing (AM) with particle-strengthened creep strength-enhanced ferritic (CSEF) steels enables fabrication and repair of critical power-plant components. Investigations focused on fusion-welded particle-strengthened CSEF steels, such as Grade 91 steel, have linked microstructurally heterogeneous regions—forming due to heat affected zones (HAZ)—with premature failure during elevated temperature service. Fusion-based AM, including WA-DED, likewise generates microstructurally and plastically heterogeneous regions due to spatiotemporally varying thermokinetics during deposition. However, works investigating such microstructural heterogeneities, their implications for mechanical behavior, and strategies to mitigate their formation remain scarce. This work identifies microstructurally and plastically heterogeneous regions within the WA-DED-processed Grade 91 steel. Spatial microhardness variations in the as-fabricated specimen correlate with the variation in the attributes of grain, martensitic microstructure, and precipitates across the fusion zone and HAZ. Digital image correlation-enabled tensile tests performed at 500 °C revealed pronounced deformation localization and a wave-like strain distribution, with wavelength close to the melt pool depth, indicating susceptibility of the as-fabricated components to premature creep failure. Such heterogeneity in microstructural and mechanical behavior was attributed to recurring solid-state phase transformations. Subsequently, an interlayer temperature control strategy was implemented, wherein maintaining interlayer temperature above the martensitic start temperature mitigated the heterogeneous microstructural and plastic response in the as-fabricated condition. Findings open pathways to achieving deformation-localization- and creep-resistant microstructures in WA-DED fabricated particle-strengthened CSEF steel components, reducing reliance on post-welding heat treatments—conventionally required to enhance creep resistance—and enabling on-demand, short lead-time fabrication of next-generation power-plant components.

Heat affected zones↗

A study on computational fluid dynamics modeling of a refrigerated container for COVID-19 vaccine distribution with experimental validation

A key issue with the distribution of vaccines to prevent COVID-19 is the temperature level required during transport, storage, and distribution. Typical refrigerated transport containers can provide a temperature-controlled environment down to -30 °C. However, the Pfizer vaccine must be carefully transported and stored under a lower temperature between -80 °C and -60 °C. One way to provide the required temperature is to pack the vaccine vials into small packages containing dry ice. Dry ice sublimates from a solid to a gas, which limits the allowable transport duration. This can be mitigated by transporting in a -30 °C refrigerated container. Moreover, because the dry ice will sublimate and thereby release CO 2 gas into the transport container, monitoring the CO 2 concentration within the refrigerated container is also essential. In the present work, a 3D computational fluid dynamics model was developed based on a commercially available refrigerated container and validated with experimental data. The airflow, temperature distribution, and CO 2 concentration within the container were obtained from the simulations. The modeling results can provide guidance on preparing experimental setups, thus saving time and lowering cost, and also provide insight into safety precautions needed to avoid hazardous conditions associated with the release of CO 2 during vaccine distribution.

59 BASIC BIOLOGICAL SCIENCES↗

Synthesis and Stabilization of Supported Metal Catalysts by Atomic Layer Deposition

Supported metal nanoparticles are among the most important cata-lysts for many practical reactions, including petroleum refining, automobile exhaust treatment, and Fischer–Tropsch synthesis. The catalytic performance strongly depends on the size, composition, and structure of the metal nanoparticles, as well as the underlying support. Scientists have used conventional synthesis methods including impregnation, ion exchange, and deposition–precipitation to control and tune these factors, to establish structure–performance relationships, and to develop better catalysts. Meanwhile, chemists have improved the stability of metal nanoparticles against sintering by the application of protective layers, such as polymers and oxides that encapsulate the metal particle. This often leads to decreased catalytic activity due to a lack of precise control over the thickness of the protective layer. A promising method of catalyst synthesis is atomic layer deposition (ALD). ALD is a variation on chemical vapor deposition in which metals, oxides, and other materials are deposited on surfaces by a sequence of self-limiting reactions. The self-limiting character of these reactions makes it possible to achieve uniform deposits on high-surface-area porous solids. Therefore, design and synthesis of advanced catalysts on the nanoscale becomes possible through precise control over the structure and composition of the underlying support, the catalytic active sites, and the protective layer. In this Account, we describe our advances in the synthesis and stabilization of supported metal catalysts by ALD. After a short introduction to the technique of ALD, we show several strategies for metal catalyst synthesis by ALD that take advantage of its self-limiting feature. Monometallic and bimetallic catalysts with precise control over the metal particle size, composition, and structure were achieved by combining ALD sequences, surface treatments, and deposition temperature control. Next, we describe ALD oxide overcoats applied with atomically precise thickness control that stabilize metal catalysts while preserving their catalytic function. We also discuss strategies for generation and control over the porosity of the overcoats that allow the embedded metal particles to remain accessible by reactants, and the details for ALD alumina overcoats on metal catalysts. Moreover, using methanol decomposition and oxidative dehydrogenation of ethane as probe reactions, we demonstrate that selectively blocking low coordination metal sites by oxide overcoats can provide another strategy to enhance both the durability and selectivity of metal catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of Slow Eigen-Zundel Interconversion in H + (H 2 O) 6 Clusters upon Isomer-Selective Vibrational Excitation and Buffer Gas Cooling in a Cryogenic Ion Trap

The formation of isomers when trapping floppy cluster ions in a temperature-controlled ion trap is a generally observed phenomenon. This involves collisional quenching of the ions initially formed at high temperature by buffer gas cooling until their internal energies fall below the barriers in the potential energy surface that separate them. Here we explore the kinetics at play in the case of the two isomers adopted by the H + (H 2 O) 6 cluster ion that differ in the proton accommodation motif. One of these is most like the Eigen cation with a tricoordinated hydronium motif (denoted E), and the other is most like the Zundel ion with the proton equally shared between two water molecules (denoted Z). After initial cooling to about 20 K in the radiofrequency (Paul) trap, the relative populations of these two spectroscopically distinct isomers are abruptly changed through isomer-selective photoexcitation of bands in the OH stretching region with a pulsed (~6 ns) infrared laser while the ions are in the trap. We then monitor the relaxation of the vibrationally excited clusters and reformation of the two cold isomers by recording infrared photodissociation spectra with a second IR laser as a function of delay time from the initial excitation. The latter spectra are obtained after ejecting the trapped ions into a time-of-flight photofragmentation mass spectrometer, thus enabling long (~0.1 s) delay times. Excitation of the Z isomer is observed to display long-lived vibrationally excited states that are collisionally cooled on a ms time scale, some of which quench into the E isomer. These excited E species then display spontaneous interconversion to the Z form on a ~10 ms time scale. Furthermore, these qualitative observations set the stage for a series of experimental measurements that can provide quantitative benchmarks for theoretical simulations of cluster dynamics and the potential energy surfaces that underlie them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

As-Run Thermal Analysis for the AGC-4 Experiment Irradiated in the ATR

The Advanced Graphite Capsule (AGC) irradiation experiment will provide irradiation creep rate data for the new graphite proposed for the Next Generation Nuclear Plant (NGNP) program. The fourth experiment in the series (AGC-4) was designed to irradiate various types of graphite specimens at a temperature of 900 ºC and targeted displacements per atom (DPA) of 6. This experiment has been irradiated in the east flux trap of the Advanced Test Reactor (ATR) during the cycles of 157D, 158A, 162A, 162B, 164A, 164B, 166A, and 166B. Temperatures were monitored using twelve thermocouples (TC) located at various elevations in the reactor core, and variable helium-argon gas mixtures were used for gas gap temperature control of the specimens. The purpose of this Engineering Calculation and Analysis Report (ECAR) is to calculate the specimen temperature after the model is calibrated by the measured TC data with the as-run heating rates of the components, DPA of the graphite, and the gas mixture compositions during the experiment. As-run specimen mean temperature and the tolerance will be obtained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Graphite resistive heated diamond anvil cell for simultaneous high-pressure and high-temperature diffraction experiments

High-pressure and high-temperature experiments using a resistively heated diamond anvil cell have the advantage of heating samples homogeneously with precise temperature control. Here, we present the design and performance of a graphite resistive heated diamond anvil cell (GRHDAC) setup for powder and single-crystal x-ray diffraction experiments developed at the Extreme Conditions Beamline (P02.2) at PETRA III, Hamburg, Germany. In the GRHDAC, temperatures up to 2000 K can be generated at high pressures by placing it in a water-cooled vacuum chamber. Temperature estimates from thermocouple measurements are within +/–35 K at the sample position up to 800 K and within +90 K between 800 and 1400 K when using a standard seat combination of cBN and WC. Isothermal compression at high temperatures can be achieved by employing a remote membrane control system. Importantly, the advantage of the GRHDAC is demonstrated through the study of geophysical processes in the Earth’s crust and upper mantle region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An optimal guarding scheme for thermal conductivity measurement using a guarded cut-bar technique, part 1 experimental study

In the guarded cut-bar technique, a guard surrounding the measured sample and reference (meter) bars is temperature controlled to carefully regulate heat losses from the sample and reference bars. Guarding is typically carried out by matching the temperature profiles between the guard and the test stack of sample and meter bars. Problems arise in matching the profiles, especially when the thermal conductivitiesof the meter bars and of the sample differ, as is usually the case. In a previous numerical study, the applied guarding condition (guard temperature profile) was found to be an important factor in measurement accuracy. Different from the linear-matched or isothermal schemes recommended in literature, the optimal guarding condition is dependent on the system geometry and thermal conductivity ratio of sample to meter bar. To validate the numerical results, an experimental study was performed to investigate the resulting error under different guarding conditions using stainless steel 304 as both the sample and meter bars. The optimal guarding condition was further verified on a certified reference material, pyroceram 9606, and 99.95% pure iron whose thermal conductivities are much smaller and much larger, respectively, than that of the stainless steel meter bars. Additionally, measurements are performed using three different inert gases to show the effect of the insulation effective thermal conductivity on measurement error, revealing low conductivity, argon gas, gives the lowest error sensitivity when deviating from the optimal condition. The result of this study provides a general guideline for the specific measurement method and for methods requiring optimal guarding or insulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A general infrastructure for data-driven control design and implementation in tokamaks

A general infrastructure for tokamak controllers based on data-driven neural net models is presented. The paradigm allows for more flexible choices of both the underlying model and the desired controlled variables and targets. The system is implemented and tested on the DIII-D tokamak, enacting simultaneous pressure and temperature control via a finite-set model-predictive controller. Traditional control methods such as proportional–integral–derivative (PID) have proven effective for decoupled control tasks, but scale poorly when trying to achieve more complicated goals such as full state control. This is exactly where model-based controllers succeed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ x-ray diffraction studies on epitaxial VO{sub 2} films grown on c-Al{sub 2}O{sub 3} during thermally induced insulator-metal transition

The structural phase transition (SPT) of VO{sub 2} films epitaxially grown on c-Al{sub 2}O{sub 3} substrates by pulsed laser deposition and reactive sputtering was investigated by in situ temperature-controlled x-ray diffraction (XRD) across metal-insulator transition (MIT). An intermediate insulator phase was observed between room temperature monoclinic phase and high temperature metallic tetragonal phase. Gaussian curve fittings for measured XRD patterns revealed a significant contribution of the intermediate phase covering wide temperature range across MIT. Polycrystalline VO{sub 2} films grown on Si substrates revealed pure rutile phase after MIT in contrast with the epitaxial films on c-Al{sub 2}O{sub 3} substrates. Strained structure of the VO{sub 2} films grown on c-Al{sub 2}O{sub 3} substrates could be a mechanism for the formation of such intermediate phase known as monoclinic M2 phase. Presence of the intermediate insulator phase in highly oriented VO{sub 2} films may be an important factor in understanding the relation between MIT and SPT.

36 MATERIALS SCIENCE↗

Passive Cooling of Photovoltaics with Desiccants

As part of efforts to reduce photovoltaic (PV) costs and improve reliability/durability, temperature control needs to be closely examined in a number of ways including novel passive cooling technology. Modest PV module operating temperature reductions can increase PV power output by 10% or more. The higher the operating temperature of a typical PV device, the lower the overall PV conversion efficiency. Because some incident light is converted to heat in PV cells, the PV module heats up (typically 25 degrees C above ambient temperature in full sun), and the overall energy output of the PV system is reduced (typically a 10% power loss for every 20 degrees C to 30 degrees C increase in temperature). We are integrating material on the PV module that adsorbs water from the air at night when the PV module temperature is cool and the relative humidity in the air is typically high. This sorbed water evaporates as the PV module heats up during the day, taking the excess heat with it and thus effectively cooling the PV module (see Fig. 1). Initial experiments with this novel passive cooling have demonstrated that PV module operating temperatures may be reduced nearly 30 degrees C with evaporative cooling. In this paper, we describe 1) novel materials development, 2) initial modeling that predicts how the cooling will work in different environments, and 3) results demonstrating the PV operating temperature reductions achieved to date.

14 SOLAR ENERGY↗