Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

Vise holds specimens for microscope

Convenient, miniature, spring-loaded clamp holds specimens for scanning electron microscope. Clamp is made out of nesting sections of studded angle-aluminum. Specimens are easier to mount and dismount with vise than with conductive adhesive or paint.

Greule, W. N.↗

Using Fission-Track Radiography Coupled with Scanning Electron Microscopy for Efficient Identification of Solid-Phase Uranium Mineralogy at a Former Uranium Pilot Mill (Grand Junction, Colorado)

At a former uranium pilot mill in Grand Junction, Colorado, mine tailings and some subpile sediments were excavated to various depths to meet surface radiological standards, but residual solid-phase uranium below these excavation depths still occurs at concentrations above background. The combination of fission-track radiography and scanning electron microscope energy-dispersive X-ray spectroscopy (SEM-EDS) provides a uniquely efficient and quantitative way of determining mineralogic associations of uranium that can influence uranium mobility. After the creation of sample thin sections, a mica sheet is placed on those thin sections and irradiated in a nuclear research reactor. Decay of the irradiated uranium creates fission tracks that can be viewed with a microscope. The fission-track radiography images indicate thin section sample areas with elevated uranium that are focus areas for SEM-EDS work. EDS spectra provide quantitative elemental data that indicate the mineralogy of individual grains or grain coatings associated with the fission-track identification of elevated uranium. For the site in this study, the results indicated that uranium occurred (1) with coatings of aluminum–silicon (Al/Si) gel and gypsum, (2) dispersed in the unsaturated zone associated with evaporite-type salts, and (3) sorbed onto organic carbon. The Al/Si gel likely formed when low-pH waters were precipitated during calcite buffering, which in turn retained or precipitated trace amounts of Fe, As, U, V, Ca, and S. Understanding these mechanisms can help guide future laboratory and field-scale efforts in determining long-term uranium release rates to groundwater.

58 GEOSCIENCES↗

The Physical and Engineering Limits of Coupled In situ TEM Experiments

Almost all future energy systems (advanced nuclear reactors, fusion energy system, concentrating solar-thermal power (CSP), and wind technologies) are limited by degradation of key material systems exposed to multiple environmental stressors. The degradation during exposure to high temperatures, radiation, mechanical loading, and chemical attack is often dictated by mechanisms active at the microstructural level. The nature of these mechanisms and the associated variations between sequential and concurrent interplay can be explored if the transmission electron microscope (TEM) is utilized as a toolbox for exploration [1]. One such tool developed at Sandia National Laboratories to couple several of these environments is the In situ Ion Irradiation TEM (I3TEM) [2]. Several studies over the last decade utilizing this tool have shown that the scientific intuition developed over decades of sequential experiments is not always a good indicator of concurrent mechanisms or failure routes. This presentation will highlight the recent and planned additions into the I3TEM facility of a Waviks gas injection system and Raman system, respectively, as can be seen in Fig. 1, permitting environmental degradation from gas species leaked into the pole piece region during quantitative mechanical loading (indentation, monotonic loading, high temperature creep, irradiation induced creep, and high-cycle fatigue); multi-beam ion irradiation (energies ranging from 1 keV to 48 MeV and species from H to Au); laser exposure (20 W and 1064 nm), or various combinations thereof that are already possible [3]. This addition permits the facility to explore both sequential or concurrently the four axes of stressors: thermal, mechanical, radiation, and chemical. This information can be directly coupled to modeling, expediting the refinement and validation of both atomistic and mesoscale models.

degradation↗

Dislocation cross-slip in precipitation hardened Mg–Nd alloys

An integrated experimental characterization and molecular dynamics (MD) simulation approach was used to explore the dislocation-precipitate interactions in a dilute Magnesium–Neodymium (Mg–Nd) precipitation hardened alloy. In situ indentation in a transmission electron microscope (TEM) and postmortem TEM characterization of deformed samples and MD simulations revealed that basal < a > type dislocations interacted differently with β 1 (Mg 3 Nd) and β"(Mg 3-7 Nd) precipitates. For β" precipitates, the basal dislocations directly shear the precipitates. For β 1 precipitates, such shearing becomes much more difficult because it requires the creation of antiphase boundaries in the ordered lattice of β 1 precipitates. Screw dislocations were observed to cross-slip from basal to the prismatic plane, which could be parallel to the broad facet of β 1 precipitates. It is postulated that double cross-slip (basal to prismatic to basal) via the Hirsch mechanism may enable screw dislocations to overcome the β 1 precipitates. MD simulations also revealed that an edge dislocation is unable to bypass the precipitate via the generation of screw dislocation segments plus the double cross-slip mechanism. The edge dislocation can bow around the precipitate, and the segment that adopts a screw character can cross-slip to the prismatic plane but with increasing applied stress, cross-slips back to the original basal plane to continue glide via precipitate shearing. Finally, the implication of glide dislocation - β 1 -precipitate interaction mechanisms on the strength and ductility of β 1 precipitate dominant microstructures is discussed.

36 MATERIALS SCIENCE↗

Dolomites in hydrated fine-grained Antarctic micrometeorites: Effective tools for analyzing secondary processes

We report detailed transmission electron microscope (TEM) observations of carbonates from one hydrated fine-grained Antarctic micrometeorite (H-FgMM). These carbonates show the occurrence of complex chemical variations and microstructures that provide important evidence regarding the formation and evolution of rarely analyzed H-FgMMs. The chemical variations were identified at both micrometer and nanometer scales, indicating that these carbonates formed under localized fluid conditions that suggest a variable chemical microenvironment. Individual carbonates grew from isolated reservoirs of fluid. Moreover, these carbonates contain manganese amounts almost twice as high as those measured in CM chondrites but similar to those identified in CI chondrites. Their particular compositions indicate reducing and progressively evolving conditions in the fluid from which these carbonates precipitated, probably due to water consumption during phyllosilicates formation. In addition to the compositional variability, microstructural features are pervasive in these carbonates, similar to those described in heavily shocked meteorites indicating that these carbonates were probably modified during shock processes after their formation. Since carbonates are highly susceptible to shock metamorphism, we suggest that it is essential to investigate their structure in detail before interpreting the isotopic measurements related to the time of their formation. Additionally, associated with carbonates, ubiquitous phosphates were identified in the micrometeorite analyzed. Future studies of these mineral associations will provide us further insight into the formation and evolution of asteroids, especially since they were both identified in the surface materials of Ryugu and Bennu.

58 GEOSCIENCES↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

Nanoscale Imaging of Optical-Frequency Plasmonic Energy Transfer in Individual Nanoparticles and their Assemblies

The nonradiative transfer of energy from plasmonic metal nanostructures to their neighboring environments is a rapidly expanding research area because of its tremendous potential impact on photovoltaics and photocatalysis. Despite the significant progress achieved via optical spectroscopies, understanding the differing and competing energy transfer pathways available to these systems still presents a major challenge due to a lack of insight into their nanoscale optical responses. With the atom-scale spatial resolving power of the electron microscope and its ability to probe optical transitions, electron spectroscopies like EELS are uniquely suited for these challenges. Our proposal addressed STEM/EELS techniques (Camden) to directly measure and even control energy transfer pathways in hybrid plasmon-resonator systems and leveraged detailed theoretical models combined with simulation (Masiello) to understand the essential underlying physics. In particular, the outcome of our proposed studies deepened the fundamental understanding of how surface plasmons shed energy to their environment and the practical knowledge gained here will influence the design of future high-efficiency solar energy-harvesting devices and photocatalysts capable of operating throughout the visible and the infrared.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurement of lattice damage caused by ion-implantation doping of semiconductors.

Discussion of two new techniques used to measure the lattice damage produced in GaAs by the implantation of 60 keV cadmium ions. In the first method, optical reflection spectra of the ion-implanted samples were measured in the wavelength range from 2000 to 4600 A. The decrease in reflectivity resulting from ion-implantation was used to determine the relative amount of lattice damage as a function of ion dose. The second technique employed the scanning electron microscope. Patterns very similar in appearance to Kikuchi electron diffraction patterns are obtained when the secondary and/or backscattered electron intensity is displayed as a function of the angle of incidence of the electron beam on a single crystal surface. The results of measurements made by both methods are compared with each other and with data obtained by the method of measuring lattice damage by Rutherford scattering of 1 MeV helium ions.

Hunsperger, R. G.↗

Controlled vapor growth of small particles of Pd and Fe on thin Al2O3 substrates

An exploratory study, dealing with the preparation of well-defined particulate metal deposits that can be used in model studies of catalytic reactions, was performed. Small metal particles of Fe and Pd were grown in situ in an electron microscope by vapor deposition onto different phase of electron transparent alumina substrates. The results show that characteristic properties of the deposits, such as particle density, size distribution, habit, and orientation, are strongly dependent on the cleanliness, phase, and crystallographic orientation of the alumina substrate; also, the deposition conditions can be chosen in such a way as to reproducibly manipulate the overall deposit structure.

Poppa, H.↗

Pu'u Poli'ahu, Mauna Kea: A Possible Analog for the Hematite Bearing Layer Located in Gale Crater, Mars.

Hyperspectral data detected by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on board Mars Reconnaissance Orbiter (MRO) indicated the presence of a hematite bearing ridge on Mount Sharp situated in the Gale Crater, Mars. [Fraeman]. The presence of this mineral in high concentrations is indicative of possible aqueous origins. [Fraeman] In 2012, Curiosity Rover landed in Gale Crater on Mars. Curiosity's mission is to determine Mars' habitability and is equipped with an advanced suite of scientific instruments that are capable of conducting analyses on rocks and soil. The hematite bearing ridge on Mount Sharp is thought to be a good candidate of study for Curiosity. To better understand this type of terrain, the study of analog sites similar in geologic setting is of great importance. One site thought to be a comparable analog is a cinder cone called Pu'u Poli'ahu located on the summit of Mauna Kea, Hawaiʻi. Poli'ahu is unique among the tephra cones of Mauna Kea because it is thought to have formed in subaqueous conditions approximately 170,000 to 175,000 years ago. [Porter] Consequently located on the inner flanks of Poli'ahu is a rock outcrop that contains hematite. Samples were collected from the outcrop and characterized using the following instruments: Digital Microscope, Panalytical X‐ray diffraction (XRD), and scanning electron microscope (SEM). The initial preparation of the rocks involved documenting each sample by creating powdered samples, thick sections, and photo documentation.

Adams, M. E.↗

Failure Analysis of Heavy-Ion-Irradiated Schottky Diodes

In this paper, we use high- and low-magnification optical microscope images, thermal infrared camera images, and scanning electron microscope images to identify failure locations in heavy-ion-irradiated Schottky diodes. After failures have been identified, the parts were cross-sectioned to describe the structure of the failures and energy dispersive x-ray spectroscopy was used to characterize the materials in the failure structures.

Radiation effects↗

Effects of Neutron Irradiation on the Micro/Nano Scale Structure and Fission Product Distribution of TRISO Coated Particle Fuel Kernels from AGR Experiments

The Advanced Reactor Technologies (ART) Program at Idaho National Laboratory (INL) includes the Advanced Gas Reactor (AGR) fuel development and qualification program that consists of fuel fabrication, experiment irradiations, post-irradiation examination (PIE) and safety testing to assess tristructural isotropic (TRISO) fuel performance during normal irradiation and under potential accident conditions. Advanced microscopy work on selected AGR-1 and AGR-2 unirradiated and irradiated fuel specimens is performed as part of the PIE effort. PIE work on fuel from the first experiment irradiation, AGR-1, began at INL in April 2010, and AGR-2 PIE began at INL in July 2014. This work scope includes University of Florida (UF) performing advanced electron microscopy examination and analysis using facilities at the Center for Advanced Energy Studies (CAES), INL or UF’s electron microscopy facilities. Electron microscopic examination and analysis may include scanning transmission electron microscopy (STEM), transmission electron microscopy (TEM), selected area diffraction (SAD), electron energy loss spectroscopy (EELS), electron dispersive spectroscopy (EDS) and atom probe tomography (APT) on the fuel kernels of TRISO-coated fuel particles. The electron microscopy lamellae will be provided by INL and will be available at CAES or Irradiated Materials Characterization Laboratory (IMCL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation sensitivity of quartz crystal oscillators experiment for the Long Duration Exposure Facility (LDEF)

Factors determining the radiation sensitivity of quartz crystal oscillators were studied on NASA's LDEF. Quartz materials were examined in the transmission electron microscope (TEM) and classified as to their sensitivity to radiation damage by establishing the rate of damage caused by the electron beam in the microscope. Two types of materials, i.e., swept premium Q quartz and natural quartz were chosen because clear differences were observed in their response to the electron beam in the TEM studies. Quartz resonators were then fabricated from them, tested for frequency stability over a greater than 6 mo. period and flown on the LDEF satellite. After retrieval (more than 7 yrs in space) the stability of the resonators was again determined. All of the space exposed resonators fabricated with swept premium Q material exhibited a frequency shift above that of the control resonators: none of the resonators fabricated from the natural quartz materials exhibited such a shift. The significant differences observed between the two types of materials in both the ground-based TEM studies and the space radiation induced frequency changes suggest that there may be a correlation between the two observations.

Ahearn, J. S.↗

Dynamic Deformation in Nuclear Graphite and Underlying Mechanisms

Time-dependent deformation in nuclear graphite is influenced by the creation and migration of radiation-induced defects in the reactor environment. This study investigates the role of pre-existing defects such as point defect clusters and Mrozowski cracks in nuclear graphite IG-110. Separate specimens were irradiated with a 2.8 MeV Au 2+ beam with a fluence of 4.38 × 10 14 cm −2 and an 8 MeV C 2+ beam with a fluence of 1.24 × 10 16 cm −2 . Microscopic specimens were either mechanically loaded inside a transmission electron microscope (TEM) or subjected to ex situ indentation-based creep loading. In situ TEM tests showed significant plasticity in regions highly localized around the Mrozowski cracks, resembling slip or ripplocation bands. Slip bands were also seen near regions without pre-existing defects but at very high stresses. Ex situ self-ion irradiation embrittled the specimens and decreased the creep displacement and rate, while heavy ion irradiation resulted in the opposite behavior. We hypothesize that the large-sized gold ions (compared to the carbon atoms) induced interplanar swelling as well as cross-plane channels for increased defect mobility. These findings illustrate the role of pre-existing defects in the dynamic relaxation of stresses during irradiation and the need for more studies into the radiation environment’s impact on the mechanical response of nuclear graphite.

creep deformation↗

The effect of microstructure on the relationship between grain boundary sliding and slip transmission in high purity aluminum

The relationship between grain boundary sliding (GBS) and slip transmission is investigated experimentally at grain boundaries in 99.99% aluminum with a through-thickness, coarse grained microstructure deformed in tension at 190 °C. Using scanning electron microscope enabled digital image correlation (SEM-DIC) and electron backscatter diffraction (EBSD), high resolution strain fields and microstructural information were measured to examine the influence of microstructural neighborhoods on interactions between GBS and slip transmission and strain localization. Several distinct cases are presented that highlight important microstructural factors that govern deformation near grain boundaries. The findings include (1) direct transmission and GBS were anti-compatible and facilitated by opposing boundary types (low misorientation and high energy grain boundaries respectively); (2) increased GBS activity was correlated with decreased indirect transmission behavior; (3) GBS accommodation at triple junctions was enabled by intragranular plasticity; and (4) the local intragranular plastic strain discontinuity between grains determined the magnitude of GBS gradients. Finally, this work provides insight into the nature of these mechanisms and can be used to identify strain transfer criteria that can lead to improved GBS-sensitive crystal plasticity models.

36 MATERIALS SCIENCE↗

Effect of aging on failure mechanism of Alloy 709 at various temperatures

Alloy 709 is a novel austenitic stainless steel with high temperature creep strength, weldability, and corrosion resistance. These properties make the material suitable for applications in the structure of next-generation nuclear power plants. Enduring high temperatures for an extended period of time in the harsh environments of a nuclear power plant results in thermal aging of the material. Therefore, it is imperative to study the effect of thermal aging on the microstructure and mechanical properties of Alloy 709 before its application in the next generation power plants. In this study, hot-processed (forged + rolled), annealed and quenched ingots of Alloy 709 are aged at 650 °C for 2000 h in air and then tested at various temperatures up to 850 °C in an in-situ heating-loading Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectroscopy (EDS) and Electron Backscatter Diffraction (EBSD). The effect of testing temperature and aging on microstructural evolutions during tensile testing of as-received and aged samples are studied. Furthermore, both as-received and aged samples displayed serrations and drop in ductility at elevated temperatures, due to the effect of dynamic strain aging (DSA). The occurrence of DSA activity was found within temperatures range of 500 °C–750 °C in as-received and 550 °C - 650 °C in aged samples. The aged samples showed less elongation accompanied by shallower dimples on the fractured surface, indicating less ductile failure mechanism compared to as-received samples. Failure mechanism observations on the fracture surface using SEM fractography are correlated to the observations made on the sample surface using in-situ SEM to achieve a complementary set of information to better understand the failure mechanism of this novel alloy.

36 MATERIALS SCIENCE↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗