Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Muon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Search for charged-lepton flavour violation in top quark interactions with an up-type quark, a muon, and a $τ$ lepton in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for charged-lepton flavour violation (CLFV) in top quark (t) production and decay is presented. The search uses proton-proton collision data corresponding to 138 fb$^{-1}$ collected with the CMS experiment at $\sqrt{s}$ = 13 TeV. The signal consists of the production of a single top quark via a CLFV interaction or top quark pair production followed by a CLFV decay. The analysis selects events containing a hadronically decaying $τ$ lepton and a muon of opposite electric charge, as well as at least three jets, one of which is identified as originating from the fragmentation of a bottom quark. Machine learning classification techniques are used to distinguish signal from standard model background events. The results of this search are consistent with the standard model expectations. The upper limits at 95% confidence level on the branching fraction $\mathcal{B}$ for CLFV top quark decays to a muon, a $τ$ lepton, and an up or a charm quark are set at $\mathcal{B}$(t $\to$ $μτ$u) $\lt$ (0.04, 0.08, and 0.12) $\times$ 10$^{-6}$, and $\mathcal{B}$(t $\to$ $μτ$c) $\lt$ (0.81, 1.71, and 2.05) $\times$ 10$^{-6}$ for scalar, vector, and tensor-like operators, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Full Detector Simulation with Unprecedented Background Occupancy at a Muon Collider

In recent years, a Muon collider has attracted a lot of interest in the high-energy physics community, thanks to its ability of achieving clean interaction signatures at multi-TeV collision energies in the most cost-effective way. Estimation of the physics potential of such an experiment must take into account the impact of beam-induced background on the detector performance, which has to be carefully evaluated using full detector simulation. Tracing of all the background particles entering the detector region in a single bunch crossing is out of reach for any realistic computing facility due to the unprecedented number of such particles. To make it feasible a number of optimisations have been applied to the detector simulation workflow. This contribution presents an overview of the main characteristics of the beam-induced background at a Muon collider, the detector technologies considered for the experiment and how they are taken into account to strongly reduce the number of irrelevant computations performed during the detector simulation. Special attention is dedicated to the optimisation of track reconstruction with the conformal tracking algorithm in this high-occupancy environment, which is the most computationally demanding part of event reconstruction.

97 MATHEMATICS AND COMPUTING↗

Isotope dependence of muon-to-electron conversion

The lepton-flavor-violating conversion of a muon into an electron in the field of a nucleus is one of the most sensitive probes of physics beyond the Standard Model and the experiments Mu2e, COMET, and DeeMe will explore uncharted terrain in the near future. An observation of this μ - → e - conversion process opens up the possibility to distinguish the underlying operator or new-physics model by exploiting the target-nucleus dependence of the conversion rate. To facilitate the choice of optimal targets we provide μ - → e - conversion rates for all stable isotopes and estimate nuclear-structure uncertainties. Our results enable studies of mixed or enriched target materials that are particularly promising for distinguishing scenarios in which the muon converts either on protons or neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadronic uncertainties versus new physics for the W boson mass and Muon g – 2 anomalies

There are now two single measurements of precision observables that have major anomalies in the Standard Model: the recent CDF measurement of the W mass shows a 7σ deviation and the Muon g – 2 experiment at FNAL confirmed a long-standing anomaly, implying a 4.2σ deviation. Doubts regarding new physics interpretations of these anomalies could stem from uncertainties in the common hadronic contributions. We demonstrate that these two anomalies pull the hadronic contributions in opposite directions by performing electroweak fits in which the hadronic contribution was allowed to float. The fits show that including the g – 2 measurement worsens the tension with the CDF measurement and conversely that adjustments that alleviate the CDF tension worsen the g – 2 tension beyond 5σ. This means that if we adopt the CDF W mass measurement, the case for new physics in either the W mass or muon g – 2 is inescapable regardless of the size of the SM hadronic contributions. Lastly, we demonstrate that a mixed scalar leptoquark extension of the Standard Model could explain both anomalies simultaneously.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon colliders to expand frontiers of particle physics

Muon colliders offer enormous potential for the exploration of the particle physics frontier but are challenging to realize. As such, a new international collaboration is forming to make such a muon collider a reality.

43 PARTICLE ACCELERATORS↗

The MuFusE large-volume diamond anvil cell for exploring muon-catalyzed fusion at higher pressures and temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion (μCF) Experiment (MuFusE), enabling the compression and heating of deuterium–tritium (d–t) mixtures to pressures and temperatures needed to advance μCF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm 3 at liquid density, pressures up to 933 MPa and temperatures up to 400 K—benchmarks that significantly exceed previously reported limits for static d–t targets.

Kalow, J. D. [Acceleron Fusion, Inc., Cambridge, M↗

The Muon Smasher’s Guide

In this work, we lay out a comprehensive physics case for a future high-energy muon collider, exploring a range of collision energies (from 1 to 100 TeV) and luminosities. We highlight the advantages of such a collider over proposed alternatives. We show how one can leverage both the point-like nature of the muons themselves as well as the cloud of electroweak radiation that surrounds the beam to blur the dichotomy between energy and precision in the search for new physics. The physics case is buttressed by a range of studies with applications to electroweak symmetry breaking, dark matter, and the naturalness of the weak scale. Additionally, we make sharp connections with complementary experiments that are probing new physics effects using electric dipole moments, flavor violation, and gravitational waves. An extensive appendix provides cross section predictions as a function of the center-of-mass energy for many canonical simplified models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the atmospheric muon rate with the MicroBooNE Liquid Argon TPC

MicroBooNE is a near-surface liquid argon (LAr) time projection chamber (TPC) located at Fermilab. We measure muons originating from cosmic interactions in the atmosphere using both the charge collection and light readout detectors. The data is compared with the cosmic-ray simulation. Agreement is found between the observation, simulation and previous results. Furthermore, the angular resolution of the reconstructed muons inside the TPC is studied in simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and testing of sMDT tubes at the University of Michigan for the ATLAS Muon Spectrometer upgrade

This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in detail. More than 99% of the tubes meet the tube QA/QC specifications based on 2100 tubes built at UM. The UM test stations are also used for QA/QC testing on the tubes constructed at Michigan State University. Furthermore, these tubes are being used to construct the sMDT chambers which will replace the current MDT chambers of the barrel inner station of the Muon Spectrometer.

47 OTHER INSTRUMENTATION↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]↗

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of Muon Campus full flow purifier for varying operational conditions and horizontal shipping

Constant ingress of impurities in Muon Campus g-2 experiment at Fermilab has resulted in reduction of efficiency of cryogenic expanders and occasional undesired downtime to flush the impurities. Due to insufficiency of current 0.06 kg/s mobile purifier, a full flow purifier is designed to be used in Muon Campus which purifies 0.24 kg/s of Helium throughput of 4 compressors through charcoal bed at 80 K and returns ambient Helium back to the system. The purifier is designed to be operated near liquid Nitrogen temperature during cold operations and up to 400 K during regeneration. Both warm and cold operational range of the purifier has required use of appropriate clearances in design due to expansion and contraction. The vessel of around 5.5 m height which is designed to be operated vertically is to be shipped horizontally. The asymmetrical position of heavy stainless steel heat exchanger in the purifier support frame and 5g vertical load design consideration for shipping has required use of shipping supports and heat exchanger rotational stops to comply with design requirements. FEA of purifier system is performed in cold, warm and shipping cases to verify that the purifier satisfies the design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetism and its coexistence with superconductivity in CaK(Fe 0.949 Ni 0.051 ) 4 As 4 : Muon spin rotation/relaxation studies

Here, the magnetic response of Ca K ( Fe 0.949 Ni 0.051 ) 4 As 4 was investigated by means of the muon spin rotation/relaxation. The long-range commensurate magnetic order sets in below the Néel temperature T N = 50.0 ( 5 ) K. The density-functional theory calculations have identified three possible muon stopping sites. The experimental data were found to be consistent with only one type of magnetic structure, namely, the long-range magnetic spin-vortex-crystal order with the hedgehog motif within the a b plane and the antiferromagnetic stacking along the c direction. The value of the ordered magnetic moment at T ≈ 3 K was estimated to be m Fe = 0.38 ( 11 ) μ B ( μ B is the Bohr magneton). A microscopic coexistence of magnetic and superconducting phases accompanied by a reduction of the magnetic order parameter below the superconducting transition temperature T c ≃ 9 K is observed. Comparison with 11, 122, and 1144 families of Fe-based pnictides points to existence of correlation between the reduction of the magnetic order parameter at T → 0 and the ratio of the transition temperatures T c / T N . Such correlations were found to be described by Machida's model for coexistence of itinerant spin-density-wave magnetism and superconductivity [K. Machida, J. Phys. Soc. Jpn. 50 , 2195 (1981) ; S. L. Bud'ko et al. , Phys. Rev. B 98 , 144520 (2018) ].

36 MATERIALS SCIENCE↗

Search for a new pseudoscalar decaying into a pair of muons in events with a top-quark pair at $\sqrt{s} = 13$ $\mathrm{TeV}$ with the ATLAS detector

A search for a new pseudoscalar a-boson produced in events with a top-quark pair, where the a-boson decays into a pair of muons, is performed using $\sqrt{s}$=13 TeV pp collision data collected with the ATLAS detector at the LHC, corresponding to an integrated luminosity of 139 fb -1 . The search targets the final state where only one top quark decays to an electron or muon, resulting in a signature with three leptons eμμ and μμμ. No significant excess of events above the Standard Model expectation is observed and upper limits are set on two signal models: $pp→t\bar{t}a$ and $pp→t\bar{t}$ with $t→H^±b, H^±→W^±a$, where $a→μμ$, in the mass ranges 15 GeV a <72 GeV and 120 GeV≤m H± ≤160 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Top Yukawa coupling measurement at the muon collider

We have presented a detailed study about the prospects for the measurement of the top Yukawa coupling in the vector boson fusion production of a top quark pair at high energy muon colliders. By employing the effective W approximation and the high energy limit for the helicity amplitudes of the subprocess W + W − → t t ¯ , we have derived the energy scaling of the statistical signal significance in the presence of the anomalous couplings by focusing on the interference term only. The sensitivity on the top Yukawa coupling decreases as the bin energy increases. For the anomalous triple gauge boson couplings and the gauge-boson-fermion couplings with E 2 energy growing behavior, the signal significance has mild increase at the beginning and starts to decrease for s ^ t t ¯ ∼ 0.2 s μ + μ − . The 95% CL on the anomalous top Yukawa coupling is projected to be 5.6% (1.7%) at a 10 (30) TeV muon collider, which is comparable to the sensitivity of 2% at the 100 TeV collider. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Search for pair production of scalar and vector leptoquarks decaying to muons and bottom quarks in proton-proton collisions at s = 13 TeV

A search for pair production of scalar and vector leptoquarks (LQs) each decaying to a muon and a bottom quark is performed using proton-proton collision data collected at s = 13 TeV with the CMS detector at the CERN LHC, corresponding to an integrated luminosity of 138 fb - 1 . No excess above standard model expectation is observed. Scalar (vector) LQs with masses less than 1810 (2120) GeV are excluded at 95% confidence level, assuming a 100% branching fraction of the LQ decaying to a muon and a bottom quark. These limits represent the most stringent to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗