Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Virtual Power Plant Profiles and Inventory

Increased adoption of distributed energy resources (DERs), growing quantities of renewable energy on the grid, and load growth from buildings, industry, and data centers are driving the need for increased demand flexibility and solutions to reliably and cost-effectively balance electricity supply and demand. In order to deploy DERs on a similar scale as conventional supply-side resources, utilities and state decision-makers are exploring a range of programmatic approaches and market designs, including Virtual Power Plants (VPP). Based on interviews with more than twenty subject matter experts on VPPs, the Insights into Scaling Virtual Power Plants report and appendix outlines actions that utilities and regulators can take to expand VPPs, organized around successful VPP designs, deployment, and operation. The companion report, Virtual Power Plant Profiles and Inventory describes three conceptual profiles that can be used as a starting point to facilitate clear discussions among regulators, utilities, solution providers, and stakeholders about various VPP strategies. It also includes details on more than 790 demand response programs and net energy metering solar plus battery programs, and 180 VPP programs. The Inventory is provided below as a separate file.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of dust on rainfall over the Red Sea coast based on WRF-Chem model simulations

Water is the single most important element of life. Rainfall plays an important role in the spatial and temporal distribution of this precious natural resource, and it has a direct impact on agricultural production, daily life activities, and human health. One of the important elements that govern rainfall formation and distribution is atmospheric aerosol, which also affects the Earth's radiation balance and climate. Therefore, understanding how dust compositions and distributions affect the regional rainfall pattern is crucial, particularly in regions with high atmospheric dust loads such as the Middle East. Although aerosol and rainfall research has garnered increasing attention as both an independent and interdisciplinary topic in the last few decades, the details of various direct and indirect pathways by which dust affects rainfall are not yet fully understood. Here, we explored the effects of dust on rainfall formation and distribution as well as the physical mechanisms that govern these phenomena, using high-resolution WRF-Chem simulations (~1.5 km × 1.5 km) configured with an advanced double-moment cloud microphysics scheme coupled with a sectional eight-bin aerosol scheme. Our model-simulated results were realistic, as evaluated from multiple perspectives including vertical profiles of aerosol concentrations, aerosol size distributions, vertical profiles of air temperature, diurnal wind cycles, and spatio-temporal rainfall patterns. Rainfall over the Red Sea coast is mainly caused by warm rain processes, which are typically confined within a height of ~6 km over the Sarawat mountains and exhibit a strong diurnal cycle that peaks in the evening at approximately 18:00 local time under the influence of sea breezes. Numerical experiments indicated that dust could both suppress or enhance rainfall. The effect of dust on rainfall was calculated as total, indirect, and direct effects, based on 10-year August-average daily-accumulated rainfall over the study domain covering the eastern Red Sea coast. For extreme rainfall events (domain-average daily-accumulated rainfall of ≥ 1.33 mm), the net effect of dust on rainfall was positive or enhancement (6.05 %), with the indirect effect (4.54 %) and direct effect (1.51 %) both causing rainfall increase. At a 5 % significance level, the total and indirect effects were statistically significant whereas the direct effect was not. For normal rainfall events (domain-average daily-accumulated rainfall < 1.33 mm), the indirect effect enhanced rainfall (4.76 %) whereas the direct effect suppressed rainfall (-5.78 %), resulting in a negative net suppressing effect (-1.02 %), all of which were statistically significant. We investigated the possible physical mechanisms of the effects and found that the rainfall suppression by dust direct effects was mainly caused by the scattering of solar radiation by dust. The surface cooling induced by dust weakens the sea breeze circulation, which decreases the associated landward moisture transport, ultimately suppressing rainfall. For extreme rainfall events, dust causes net rainfall enhancement through indirect effects as the high dust concentration facilitates raindrops to grow when the water vapor is sufficiently available. Our results have broader scientific and environmental implications. Specifically, although dust is considered a problem from an air quality perspective, our results highlight the important role of dust on sea breeze circulation and associated rainfall over the Red Sea coastal regions. Our results also have implications for cloud seeding and water resource management.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Post-Disaster Microgrid Formation for Enhanced Distribution System Resilience

This paper proposes a deep reinforcement learning (DRL) based approach for post-disaster critical load restoration in active distribution systems to form microgrids through network reconfiguration to minimize critical load curtailments. Distribution networks are represented as graph networks, and optimal network configurations with microgrids are obtained by searching for the optimal spanning forest. The constraints to the research question being explored are the radial topology and power balance. Unlike existing analytical and population-based approaches, which necessitate the repetition of entire analyses and computation for each outage scenario to find the optimal spanning forest, the proposed approach, once properly trained, can quickly determine the optimal, or near-optimal, spanning forest even when outage scenarios change. When multiple lines fail in the system, the proposed approach forms microgrids with distributed energy resources in active distribution systems to reduce critical load curtailment. The proposed DRL-based model learns the action-value function using the REINFORCE algorithm, which is a model-free reinforcement learning technique based on stochastic policy gradients. A case study was conducted on a 33-node distribution test system, demonstrating the effectiveness of the proposed approach for post-disaster critical load restoration.

active distribution systems↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

JEDEC Tray Flexures for High-Consequence Electronics

JEDEC matrix trays are an industry standard for the safe handling, transport, and storage of electronics. Manufacturing tolerances of the trays (typical for injection-molded components) forces the creation of an envelope around components rather than a secure interface to prevent the trays themselves from damaging the electronics during use. However, this allows relative motion between the components, another potential damage source. This paper covers the design of tray features (flexures) than enable intentional, tuned contact preload to prevent relative motion, maximizing component safety while keeping the JEDEC tray form-factor. The target preload is balanced between gravity and shipment forces that could be experience during adverse handling or transport to prevent loss of contact or slip and keeping the load itself low enough to prevent component damage. Typical features/dimensions for JECEC trays were employed to maximize utility and minimize tray fabrication difficulty. The design also increases usability and component safety by making the chips visible while still sandwiched between trays. The point design described here exemplifies a simple, easy-to-manufacture tray-matrix flexure that significantly improves the security of supported components

42 ENGINEERING↗

Optimal Network Reconfiguration and Scheduling With Hardware-in-the-Loop Validation for Improved Microgrid Resilience

With the increased occurrence of various major extreme weather events, power outages and prompt power system restorations have recently drawn more attention to the resilience and recovery of power systems. From the perspective of a more resilient power delivery at the distribution grid, system restoration using network topology reconfiguration together with optimal scheduling of distributed energy resources are adopted in this paper. The proposed optimization model aims at minimizing the total load shedding cost and other operational costs, in which linearized topological constraints borrowed from graph theory and linearized DistFlow models are respectively used to maintain the radial network topology and power flow balance after system contingencies. To demonstrate the applicability of the proposed strategy, a real-world case study of a networked three-microgrid system in Adjuntas, Puerto Rico, is used with the consideration of different independent/interconnected microgrid scenarios, contingencies, and fairness settings. Furthermore, hardware-in-the-loop testing is conducted for the same three-microgrid network, where the closely matched results with the simulated ones have validated the effectiveness of the proposed restoration strategy, which is now ready to move one step forward towards field deployment. Finally, to test the proposed restoration strategy in a larger networked system, the modified IEEE-33 bus test distribution system is considered, and the results show a more resilient power delivery for critical loads under three and four line outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of catholyte for halide-based all-solid-state batteries

Halide solid electrolytes gain significant attention due to their high ionic conductivity, low processing temperature, dry air compatibility, and high-voltage stability. However, low cathode active material (CAM) loading in the composite cathode constrains the realization of high energy density for halide-based all-solid-state batteries. In this study, three halide materials, raw Li 3 YBrCl 5 (LYBC-R, <30μm), milled LYBC (LYBC-M, <5 μm) and freeze-dried Li 3 InCl 6 (LIC, <500 nm), were used as catholytes, combined with LYBC-M as the electrolyte and LiIn alloy as the anode. The CAM:catholyte ratio was investigated as well as stack pressure and operating temperature. Our study demonstrates that particle size of the catholyte plays an important role only for high CAM loading or high C-rate cycling. At moderate CAM loading (65 and 70wt% LiNi 0.83 Mn 0.06 Co 0.11 O 2 ) and 0.1 C-rate, all the three catholytes perform well, providing initial discharge capacities >177 mAh/g. At high CAM loading (85wt%) and 0.1 C-rate, a cathode with the nano-scale LIC catholyte provides discharge capacity of 175 mAh/g, while the larger particle size catholytes suffer significantly reduced capacity. Both LYBC and LIC catholytes provided capacity retention >80% after 200 cycles at 0.5C. These results imply that cathode particle size is critically important for performance at high CAM loading. Furthermore, both electrolyte and cathode were tape cast to scale up size and prepare realistic layer thicknesses. A small amount of binder was used in both layers, to balance the electrochemical performance and mechanical properties. Further, the discharge capacity of a tape cell was 152mA h/g at 0.1C with a capacity retention of 81.8% after 20 cycles at 0.5C. The results demonstrate the excellent performance of LYBC as an electrolyte, and provide guidance for halide-based cathode design.

25 ENERGY STORAGE↗

Empirical Indicators of Transmission Value in the Southeast United States

Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Power Density, Carbon Neutral Electrical Power Generation for Air Vehicles

The synergistic integration of a Solid Oxide Fuel Cell-Combustor (SOFC-C) with a turbogenerator (TG) will provide a very high fuel-to-electricity conversion efficiency while maintaining high power-to-weight ratio during high-altitude flight. The proposed SOFC-C-TG power generation technology exceeds the REEACH technical performance targets (TPT). This unique concept addresses many of the challenges faced in all electric propulsion-based aviation. The system has high part-load efficiency (more than 65% lower heating value (LHV)) during long cruise times, load following capability, high-power capacity at high altitudes adapting to low temperatures and pressures, rapid startup time of less than 30 minutes (proven with current SOFC technology), high power density (more than 3.2 kW/kg), efficient thermal management, and a foundation for a compact, efficient electrical storage and power generation system (ESPG). The SOFC-C concept achieves the technology targets by reducing the complexity of traditional fuel cell-gas turbine hybrid systems (FC-GT). The SOFC-C does not require heat exchangers and dramatically reduces the balance of plant increasing power density and performance in efficiency. The reduction in mass through elimination of heat exchangers, external reformer, and other components dramatically decreases the overall thermal dampening of the system which enables rapid startup and load following capability. Direct control of the cathode inlet temperature of the SOFC-C enables rapid warm-up of the SOFC tubes with the ability to reach operating temperature and full power in less than 30 minutes.

03 NATURAL GAS↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

Model estimates of dissolved organic carbon, runoff, snowmelt, and snow water equivalent from 1981-2010 across the western Arctic

This dataset contains estimates of dissolved organic carbon (DOC) yield (mg C m-2), runoff (mm day-1), snow water equivalent (SWE, mm day-1), and snowmelt (mm day-1) from a simulation of the Permafrost Water Balance Model (PWBM v4). The simulation effectively quantifies snowpack accumulation and melt, runoff, and DOC leaching, and broadly capture the seasonal cycle in DOC concentration and mass loadings. Daily air temperature, precipitation, and wind speed data from the Modern-Era Retrospective Analysis for Research and Applications (MERRA) were used for meteorological forcings. The model outputs are organized by grid and day of the month in gzipped ASCII text files contained within each archived ZIP file. No special software is required to work with these data. The basin and domain information files are also ASCII text. The gridded estimates are most useful for analyses of the spatial and temporal variations in terrestrial hydrology and leachate DOC concentrations and loadings across parts of the western Arctic. A manuscript describing the data and associated analysis has been accepted for publication in Journal of Geophysical Research - Biogeosciences (Rawlins et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Deployment Potential of Concentrating Solar Power Technologies in California

As states within the United States respond to future grid development goals, there is a growing demand for reliable and resilient nighttime generation that can be addressed by low-cost, long-duration energy storage solutions. This report studies the potential of including concentrating solar power (CSP) in the technology mix to support California’s goals as defined in Senate Bill 100. A joint agency report study that determined potential pathways to achieve the renewable portfolio standard set by the bill did not include CSP, and our work provides information that could be used as a follow-up. This study uses a capacity expansion model configured to have nodal spatial fidelity in California and balancing-area fidelity in the Western Interconnection outside of California. The authors discovered that by applying current technology cost projections CSP fulfills nearly 15% of the annual load while representing just 6% of total installed capacity in 2045, replacing approximately 30 GWe of wind, solar PV, and standalone batteries compared to a scenario without CSP included. The deployment of CSP in the results is sensitive to the technology’s cost, which highlights the importance of meeting cost targets in 2030 and beyond to enable the technology’s potential contribution to California’s carbon reduction goals.

14 SOLAR ENERGY↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Packetized Energy Management: Coordinating Transmission and Distribution (Final Report)

The project Packetized Energy Management (PEM): Coordinating Transmission and Distribution was part of the ARPA-E NODES program from 2015 to 2023. The high-level goal of the project was to develop and demonstrate novel, scalable, and impactful technologies related to the coordination of networked distributed energy resources (DERs). By demonstrating responsive means by which fleets of DERs could be coordinated to enhance grid operation and reliability, the U.S. could accelerate renewable integration and electrification efforts and meet decarbonization goals.

25 ENERGY STORAGE↗

Mechanism of drying-induced change in the physical properties of concrete: A mesoscale simulation study

Although many studies have found that drying alters the mechanical properties of concrete, the mechanism behind this change remains unclarified. The aim of this study is to elucidate the mechanism of change in properties of concrete after drying through the numerical calculation: a 3D mesoscale rigid-body-spring model (RBSM) with three phases, i.e. mortar, aggregate, and the interfacial transition zone while considering the properties changes of mortar due to drying. Based on the RBSM results, it is concluded that the change in compressive strength due to drying and heating is determined by a balance of the impact of drying-induced microcracking around coarse aggregates and the change in mechanical properties of the mortar due to drying. These mechanisms change the applied load required to reach the critical crack width and distribution, at which rim of the specimen begins to isolate from the core region and the load sustained by the rim decreases.

36 MATERIALS SCIENCE↗