Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cold-flow Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

681 records · Page 2

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Nonintrusive Diagnostic Strategies for Arcjet Stream Characterization

In the previous lecture, the issues related to arcjet flow modeling were introduced, and the limitations of conventional instrumentation in addressing these issues were discussed. The general level of understanding of the arcjet flows was seen to preclude the use of arcjets as aerothermodynamic test facilities beyond the current role in aerothermal material testing, despite their long test duration capability. In this section, the focus will be on new developments in spectroscopic instrumentation and techniques that can be brought to bear on the fundamental problem of arcjet stream characterization. Although a wide selection of arcjet facilities were introduced in the previous section, the discussion of nonintrusive diagnostic instrumentation will be restricted to the large-scale, segmented, constricted-arc heater facilities that are most widely used in thermal protection material testing for aerospace applications. After a brief review of the important features of arcjet flows, the topic of nonintrusive, optical diagnostics is introduced with a discussion of some of the basic aspects of radiative transitions. The lecture is then organized into two sections covering emission measurements and laser-induced fluorescence measurements. Emission measurements are presented next for different regions of arcjet flows, while the fluorescence measurements are presented for the free stream region only. Summaries are given for each of the two main sections, and observations on arcjet characterization by optical diagnostics in general are given at the end.

Douglas G Fletcher

Fatigue Life of Flow-Formed Aluminum 2195 and 6061 Alloys

The successful design and fabrication of metallic cryotanks for commercial aviation applications require lightweight, durable materials capable of withstanding high pressures and cryogenic temperatures through tens of thousands of thermomechanical refueling cycles. Flow forming is an advanced manufacturing technique that offers high-rate production and scalability for fabricating integrally stiffened cylinders suitable for cryotank applications. This work establishes the durability of flow-formed aluminum alloys by characterizing their fatigue life performance under conditions that mimic cryotank refueling cycles. Residual stresses in flow-formed aluminum-lithium (Al-Li) 2195-T6 cylinders were assessed using the contour method and found to be minimal. Fatigue life testing was conducted on flow-formed Al-Li 2195-T6 at room temperature and cryogenic temperatures (-321°F [-196°C]), with wrought Al-Li 2195-T6 serving as a baseline for comparison. Results showed that flow-formed materials exhibited fatigue performance comparable to or better than wrought materials, with no statistically significant differences observed between different specimen orientations relative to processing directions. Fractography revealed reduced delaminations in the flow-formed Al-Li 2195 samples as compared to wrought, indicating potential improvement to the microstructure that could result in improved service properties. Texture analysis using electron backscattered diffraction (EBSD) indicated recrystallization during heat treatment, potentially contributing to reduced delamination susceptibility. These findings demonstrating flow-formed material durability coupled with the high manufacturing efficiency of flow forming, makes flow forming an attractive process to produce aircraft cryotanks.

EBF3

Proceedings of the 25th International Instrumentation Symposium, May 7-10, 1979, Anaheim, California

The papers deal essentially with the instrumentation needs of the transportation industry, machinery diagnostics, and energy research. The sessions covered include: acoustic emission, reentry vehicle ground and flight testing, performance of nose tip materials, instrumentation for solar heating and cooling systems, vibration measurement, data acquisition and analysis, system for aerospace pressure measurements, wind tunnel instrumentation and control, energy source instrumentation, nondestructive testing, pressure and flow measurements, automated test facilities, strain measurements, electrooptical instrumentation, thermal measurements, microcomputer applications in instrumentation and automation, flight testing, blast pressure measurement, two-phase liquid/gas mass flow measurement, and machinery monitoring and instrumentation.

Conferences

The 60-MW Shuttle Interaction Heating Facility

An arc-heated wind-tunnel system described in the present paper will simulate aerodynamic heating in large-scale tests of the thermal protection system of the Shuttle Orbiter Vehicle during entry. The system provides for large-scale subsystem tests in high-enthalpy streams with boundary layer flows at high Reynolds numbers and for large test-body sizes in stagnation flows. The discussion covers the design concept of the arc-jet systems, the extensive hardware developments of the arc heater to provide reliable operation, and verification and performance measurements of the system's operating envelopes.

W Winovich

GOES-R Lithium-Ion Battery Life Test & Workhorse Battery Performance

The GOES R series lithium-ion battery life test results are presented for the next-generation GOES R series weather satellites. Lockheed Martin is under contract to NASA Goddard to build and deliver four GOES-R series satellites which are operated by NOAA. In addition, Lockheed Martin is required to build a GOES R series flight battery to flight drawings and processes and perform an accelerated geosynchronous earth-orbiting (GEO) life test consisting of 30 real-time eclipse seasons and 30 accelerated solstice seasons. The GOES R series batteries are designed and built by Saft America, Inc. Space and Defense Division in Cockeysville, MD with Saft VL48E cells. The GOES R series life test battery which has been built to flight drawings and processes has undergone 21 seasons of accelerated GEO testing (which is equivalent to over 10 years on-orbit). This presentation includes a description of the life test and latest test results through season 20. The life test battery capacity measurements prior to cycling and after seasons 4, 10, and 20 which have shown little or no change are summarized. In addition, the performance of the GOES R series workhorse batteries performance are presented. These GOES R series workhorse batteries are used during spacecraft testing and have shown no discernable capacity loss after 7 years of mostly ambient operation and cold storage since activation. An overview of the electrical power subsystem and battery charge is, also, addressed.

Tucker, Jon

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series are: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and to develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

Ben Swartout

Mitigating Grazing Flow Impedance Eduction Errors in Additively Manufactured Porous Liners

Additively manufactured porous metamaterials, including triply periodic minimal surface (TPMS) cores, are promising candidates for aeroengine liners but often behave as extended-reacting treatments under grazing flow. Standard impedance eduction procedures assume locally-reacting behavior and can yield physically inconsistent results for such materials. This study evaluates internal partitions (thin solid walls inserted at regular intervals along the liner’s streamwise extent) as a means of suppressing internal streamwise propagation to improve eduction consistency. Six TPMS configurations were tested in the NASA Langley Grazing Flow Impedance Tube (GFIT) at partition spacings of 4′′, 2′′, and 1′′, as well as unpartitioned, and at Mach numbers up to 0.3. For most geometries, 2′′ partition spacing eliminated impedance discontinuities and substantially improved Prony correlation, though effectiveness varied with core topology. Partitions also altered the acoustic response of the liners: resistance increased, resonance frequencies shifted downward, and peak attenuation decreased while bandwidth broadened in some cases. Because partitions modify the liner itself, the educed impedance characterizes the partitioned system rather than the original unpartitioned core. These results establish partitioning as a practical pathway toward liners that are more compatible with standard eduction methods, while demonstrating that the intervention is itself an acoustic design change.

liners

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC

High Efficiency Centrifugal Compressor for Rotorcraft Applications

The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were measured at design flow rate and speed. The measured efficiency and stall margin were lower than pre-test CFD predictions by 2.4 percentage points (pt) and 4.5 pt, respectively. Initial impressions from the experimental data indicated that the loss in the efficiency and stall margin can be attributed to a design shortfall in the impeller. However, detailed investigation of experimental data and post-test CFD simulations of higher fidelity than pre-test CFD, and in particular the unsteady CFD simulations and the assessment with a wider range of turbulence models, have indicated that the loss in efficiency is most likely due to the impact of unfavorable unsteady impeller/diffuser interactions induced by diffuser vanes, an impeller/diffuser corrected flow-rate mismatch (and associated incidence levels), and, potentially, flow separation in the radial-to-axial bend. An experimental program with a vaneless diffuser is recommended to evaluate this observation. A subsequent redesign of the diffuser (and the radial-to-axial bend) is also recommended. The diffuser needs to be redesigned to eliminate the mismatching of the impeller and the diffuser, targeting a slightly higher flow capacity. Furthermore, diffuser vanes need to be adjusted to align the incidence angles, to optimize the splitter vane location (both radially and circumferentially), and to minimize the unsteady interactions with the impeller. The radial-to-axial bend needs to be redesigned to eliminate, or at least minimize, the flow separation at the inner wall, and its impact on the flow in the diffuser upstream. Lessons were also learned in terms of CFD methodology and the importance of unsteady CFD simulations for centrifugal compressors was highlighted. Inconsistencies in the implementation of a widely used two-equation turbulence model were identified and corrections are recommended. It was also observed that unsteady simulations for centrifugal compressors require significantly longer integration times than what is current practice in industry.

Gorazd Medic

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Design and Performance of an Experimental Annular Turbojet Combustor With High-Velocity-Air Admission Through One Wall

An experimental, annular, turbojet combustor was designed to eliminate the conventional combustor-inlet diffuser. Instead, high-velocity air was supplied directly to the combustor. This stream was split into two parts: (1) the primary in which combustion was sustained, and (2) the secondary in which the stream momentum was used to facilitate mixing with the hot primary gases. The air was admitted through only one wall of the combustor liner except for approximately 5 percent that was used to cool the inner combustor surfaces. By integrating the inlet and outlet diffuser design with the combustion chamber, an overall reduction in length of 30 percent was obtained over conventional configurations. A rectangular segment of this combustor was tested with vaporized propane fuel.

Annular Flow

Nitrile/Buna N Material Failure Assessment for an O-Ring used on the Gaseous Hydrogen Flow Control Valve (FCV) of the Space Shuttle Main Engine

After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.

Doug Wingard

Cryopump for Large Pulses of Hydrogen

A test involving a flow of hot hydrazine decomposition products at a rate of 13.6 g/s (0.03 lb/s) established the requirement to maintain pressure in an 11.9-m-(39 ft) diameter space chamber below 200 microns. The flow, 2/3 hydrogen and 1/3 nitrogen by volume, continued for several periods ranging from 3 to 15 min. The pressure requirement was necessary to minimize thermal effects of the gas on the test vehicle but was well beyond the capability of the existing facility pumps. Various methods of obtaining additional temporary jump capacity were considered. From these, the slugged-charcoal approach was selected as the quickest and least expensive method to implement.

B C Moore

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

xEMU

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

thermal analysis

Predicting Operational Performance of xEMU Boot at Lunar South Pole Temperatures using Thermal Desktop ®

The spacesuit boots that will be used on Artemis lunar south pole surface missions will be exposed to extremely cold temperatures (down to ~50 K). To assess the performance of the government’s Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these permanently shadowed regions, testing was performed at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU CITADEL TVAC test. Expected thermal conductances within the boot and between the boot and environment were calculated from test data, which was then used as an initial guess for conductances within a Thermal Desktop (TD) model. Correlation of the TD model using the internal SOLVER feature was performed across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. Operational performance at the lunar south pole was then predicted using results from the correlated model. While the predictions provide evidence for acceptable performance of the boots at the 100K environment test point, there is still substantial uncertainty in performance, especially at the 48K test point. This uncertainty is due in part to testing limitations such as contacting the foot to a hard metal plate rather than granular regolith, and model limitations such as the lack of a realistic foot model. These limitations and their impacts are addressed in detail in this paper. The results of this test series and model correlation underscore the importance of additional improved testing and modeling for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

Spacesuit