Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CALORIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Geant4 simulations of sampling and homogeneous hadronic calorimeters with dual readout for future colliders

Calorimeters with dual readout measure both scintillation and Cherenkov light produced in their active media. They offer improvements in energy resolution and, therefore, have become increasingly interesting due to the need for precision jet measurements at Higgs factories. Furthermore, this paper presents GEANT4 simulations of single-particle responses in sampling and homogeneous calorimeters, and demonstrates the effect of inclusion of Cherenkov light in the reconstruction of energies.

Detector modeling and simulations

Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO 4 ) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection, providing monitoring of the detector response and verification of the calibration with a precision better than 1%. In conclusion, the paper describes the design, installation, and performance of the light monitoring system.

Lead tungstate calorimeter

Refining fast calorimeter simulations with a Schrödinger Bridge

Machine learning-based simulations, especially calorimeter simulations, are promising tools for approximating the precision of classical high energy physics simulations with a fraction of the generation time. Nearly all methods proposed so far learn neural networks that map a random variable with a known probability density, like a Gaussian, to realistic-looking events. In many cases, physics events are not close to Gaussian and so these neural networks have to learn a highly complex function. We study an alternative approach: Schrödinger bridge Quality Improvement via Refinement of Existing Lightweight Simulations (SQuIRELS). SQuIRELS leverages the power of diffusion-based neural networks and Schrödinger bridges to map between samples where the probability density is not known explicitly. We apply SQuIRELS to the task of refining a classical fast simulation to approximate a full classical simulation. On simulated calorimeter events, we find that SQuIRELS is able to reproduce highly non-trivial features of the full simulation with a fraction of the generation time.

Calorimeter methods

Anomaly detection with flow-based fast calorimeter simulators

Recently, several normalizing flow-based deep generative models have been proposed to accelerate the simulation of calorimeter showers. Using caloflow as an example, we show that these models can simultaneously perform unsupervised anomaly detection with no additional training cost. As a demonstration, we consider electromagnetic showers initiated by one (background) or multiple (signal) photons. The caloflow model is designed to generate single-photon showers, but it also provides access to the shower likelihood. We use this likelihood as an anomaly score and study the showers tagged as being unlikely. As expected, the tagger struggles when the signal photons are nearly collinear but is otherwise effective. This approach is complementary to a supervised classifier trained on only specific signal models using the same low-level calorimeter inputs. While the supervised classifier is also highly effective at unseen signal models, the unsupervised method is more sensitive in certain regions, and, thus, we expect that the ultimate performance will require a combination of these approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Search for neutral long-lived particles that decay into displaced jets in the ATLAS calorimeter in association with leptons or jets using pp collisions at $\sqrt{\textrm{s}}$ = 13 TeV

A search for neutral long-lived particles (LLPs) decaying in the ATLAS hadronic calorimeter using 140 fb -1 of proton-proton collisions at $\sqrt{s}$ = 13 TeV delivered by the LHC is presented. The analysis is composed of three channels. The first targets pair-produced LLPs, where at least one LLP is produced with sufficiently low boost that its decay products can be resolved as separate jets. The second and third channels target LLPs respectively produced in association with a W or Z boson that decays leptonically. In each channel, different search regions target different kinematic regimes, to cover a broad range of LLP mass hypotheses and models. No excesses of events relative to the background predictions are observed. Higgs boson branching fractions to pairs of hadronically decaying neutral LLPs larger than 1% are excluded at 95% confidence level for proper decay lengths in the range of 30 cm to 4.5 m depending on the LLP mass, a factor of three improvement on previous searches in the hadronic calorimeter. The production of long-lived dark photons in association with a Z boson with cross-sections above 0.1 pb is excluded for dark photon mean proper decay lengths in the range of 20 cm to 50 m, improving previous ATLAS results by an order of magnitude. Finally, long-lived photo-phobic axion-like particle models are probed for the first time by ATLAS, with production cross-sections above 0.1 pb excluded in the 0.1 mm to 10 m range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Autoencoder-Based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online data quality monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. In addition, the first results from deploying the autoencoder-based system in the CMS online data quality monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.

Simulating the CMS High Granularity Calorimeter with ML

Detector simulation is a key component of physics analysis and related activities in CMS. In the upcoming High Luminosity LHC era, simulation will be required to use a smaller fraction of computing in order to satisfy resource constraints. At the same time, CMS will be upgraded with the new High Granularity Calorimeter (HGCal), which requires significantly more resources to simulate than the existing CMS calorimeters. This computing challenge motivates the use of generative machine learning models as surrogates to replace full physics-based simulation. We study the application of state-of-the-art diffusion models to simulate particle showers in the CMS HGCal. We will discuss methods to overcome the challenges posed by the high-dimensional, irregular geometry of the HGCal. The quality of the showers produced by the diffusion model will be assessed by comparison to the full GEANT4-based simulation. The increase in simulation throughput will be quantified and methods to accelerate the diffusion model inference will also be discussed.

Amram, Oz

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

The Mu2e Calorimeter

The EM CsI crystals and SiPM readout calorimeter of the Mu2e experiment is fully assembled, with all components completed and tested; the mechanical structure is fully built, with a complete integration and test of all the analog sensors and electronics. The digital electronics is being produced and installed. We summarise the Calorimeter characteristics and the assembly status, as well as the move, installation and commissioning plans of the final disks in the Mu2e hall.

Borrel, L. [Caltech]