The EM CsI crystals and SiPM readout calorimeter of the Mu2e experiment is fully assembled, with all components completed and tested; the mechanical structure is fully built, with a complete integration and test of all the analog sensors and electronics. The digital electronics is being produced and installed. We summarise the Calorimeter characteristics and the assembly status, as well as the move, installation and commissioning plans of the final disks in the Mu2e hall.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Borrel, L. [Caltech], Bloise, C. [Frascati], Ceravolo, S. [Frascati], Cervelli, F. [INFN, Pisa], Colao, F. [Frascati; ENEA, Frascati], Di Falco, S. [INFN, Pisa], Diociaiuti, E. [Frascati], Donati, S. [INFN, Pisa], Echenard, B. [Caltech], Fedeli, P. [Frascati; Rome U.], Ferrari, C. [INFN, Pisa; CNR, INO, Pisa], Gioiosa, A. [U. Salento, Lecce (main)], Giovannella, S. [Frascati], Giusti, V. [INFN, Pisa], Hampai, D. [Frascati], Happacher, F. [Frascati], Hitlin, D. G. [Caltech], Martini, M. [Frascati; Rome U.], Middleton, S. [Caltech], Miscetti, S. [Frascati], Morescalchi, L. [INFN, Pisa], Paesani, D. [INFN, LNS], Pasciuto, D. [Rome U.], Pedreschi, E. [INFN, Pisa], Porter, F. [Caltech], Raffaelli, F. [INFN, Pisa], Saputi, A. [INFN, Ferrara], Sarra, I. [Frascati], Spinella, F. [INFN, Pisa], Zaffara, A. [INFN, Pisa], Zhu, R. Y. [Caltech]. 2025-02-24. The Mu2e Calorimeter. https://doi.org/10.22323/1.476.1060