Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ATOMIC BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.↗

Method and apparatus for producing a thermal atomic oxygen beam

Atomic oxygen atoms are routed to a material through a sufficiently tortuous path so that vacuum ultraviolet radiation is obstructed from arriving at the surface of the material. However, the material surface continues to be exposed to the atomic oxygen.

Banks, Bruce A.↗

Atom beam surface interaction studies: Experimental system development

Quantitative deposition by standard techniques of adsorbates containing C and Si onto selected substrates is studied. The interaction kinetics of a beam of oxygen, nitrogen, or hydrogen atoms of known flux are investigated by Auger electron spectroscopy and LEED. Desborbed molecules will be analyzed by mass spectroscopy using modulated beam techniques. Experimental conditions permitting, two sets of measurements will be correlated.

Gregory, J. C.↗

Vacuum ultraviolet laser induced fluorescence on a Si atomic beam

A broadly applicable vacuum ultraviolet experiment is described for measuring radiative lifetimes of neutral and singly-ionized atoms in a beam environment to 5-percent accuracy using laser induced fluorescence. First results for neutral Si are reported.

O'Brian, T. R.↗

High intensity copper atom beam - Preliminary results

The development of a nozzle which gas-dynamically accelerates neutral copper atoms at controlled energy levels and flux rates suitable for the investigation of inelastic copper atom collision processes is reported. Preliminary test data demonstrate that vapor-deposited rhenium nozzles do not degrade in the presence of copper vapor at high temperatures. Operation with high purity helium gas at nozzle stagnation temperatures in the range 2650-2700 K and total stagnation pressures from 1/4 to 2 atm with continuous copper atom flux rates of approximately 10 to the 18th power per second has been maintained, for a total time of 8-1/2 h to date.

Kelly, A. J.↗

Microgravity Electron Electric Dipole Moment Experiment with a Cold Atom Beam

New physics beyond the Standard Model: The small CP violation contained in the Standard Model is insufficient to account for the baryon/antibaryon asymmetry in the universe. New sources of CP violation are provided by extensions to the Standard Model. They contain CP-violating phases that couple directly to leptons and from which a large electron electric dipole moment (EDM) may be generated. Observation of an electron EDM would be proof of a Standard Model extension because the Standard Model only allows an electron EDM of less than 10(exppp -57) C-m (S.I. units; 1 C-m = 1.6 x 10(exp -21) e-cm). A null result, however, constrains models and improving the limit tightens constraints, further restricting the models.

Gould, Harvey↗

Means and method for calibrating a photon detector utilizing electron-photon coincidence

An arrangement for calibrating a photon detector particularly applicable for the ultraviolet and vacuum ultraviolet regions is based on electron photon coincidence utilizing crossed electron beam atom beam collisions. Atoms are excited by electrons which lose a known amount of energy and scatter with a known remaining energy, while the excited atoms emit photons of known radiation. Electrons of the known remaining energy are separated from other electrons and are counted. Photons emitted in a direction related to the particular direction of scattered electrons are detected to serve as a standard. Each of the electrons is used to initiate the measurements of a time interval which terminates with the arrival of a photon exciting the photon detector. Only the number of time intervals related to the coincidence correlation and of electrons scattered in the particular direction with the known remaining energy and photons of a particular radiation level emitted due to the collisions of such scattered electrons are counted. The detector calibration is related to the number of counted electrons and photons.

Srivastava, S. K.↗

Atom Skimmers and Atom Lasers Utilizing Them

Atom skimmers are devices that act as low-pass velocity filters for atoms in thermal atomic beams. An atom skimmer operating in conjunction with a suitable thermal atomic-beam source (e.g., an oven in which cesium is heated) can serve as a source of slow atoms for a magneto-optical trap or other apparatus in an atomic-physics experiment. Phenomena that are studied in such apparatuses include Bose-Einstein condensation of atomic gases, spectra of trapped atoms, and collisions of slowly moving atoms. An atom skimmer includes a curved, low-thermal-conduction tube that leads from the outlet of a thermal atomic-beam source to the inlet of a magneto-optical trap or other device in which the selected low-velocity atoms are to be used. Permanent rare-earth magnets are placed around the tube in a yoke of high-magnetic-permeability material to establish a quadrupole or octupole magnetic field leading from the source to the trap. The atoms are attracted to the locus of minimum magnetic-field intensity in the middle of the tube, and the gradient of the magnetic field provides centripetal force that guides the atoms around the curve along the axis of the tube. The threshold velocity for guiding is dictated by the gradient of the magnetic field and the radius of curvature of the tube. Atoms moving at lesser velocities are successfully guided; faster atoms strike the tube wall and are lost from the beam.

Hulet, Randall↗

Atomic oxygen beam source for erosion simulation

A device for production of low-energy (5-10 eV) neutral atomic beams for surface modification studies, which recreates the flux of atomic oxygen in LEO, is described. The beam is produced by acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining a large fraction of their incident kinetic energy, forming a beam of atoms. The device is based on a magnetically confined (3-4 kG) coaxial plasma source and the atom energy can be varied by adjusting the bias voltage. The source provides a neutral flux of roughly 5 x 10 to the 16th/sq cm/s at a distance of 10 cm and a fluence of roughly 10 to the 21st/sq cm in five hours. The source has been characterized with plasma diagnostics and by measuring the energy of an atomic argon beam using a mass spectrometer. Samples of carbon film, carbon-based paint, Kapton, Mylar, and Teflon exposed to atomic O beams show erosion quite similar to those observed in orbit on the Space Shuttle.

Cuthbertson, J. W.↗

Isotope separation using tuned laser and electron beam

The apparatus comprises means for producing an atomic beam containing the isotope of interest and other isotopes. Means are provided for producing a magnetic field traversing the path of the atomic beam of an intensity sufficient to broaden the energy domain of the various individual magnetic sublevels of the isotope of interest and having the atomic beam passing therethrough. A laser beam is produced of a frequency and polarization selected to maximize the activation of only individual magnetic sublevels of the isotope of interest with the portion of its broadened energy domain most removed from other isotopes with the stream. The laser beam is directed so as to strike the atomic beam within the magnetic field and traverse the path of the atomic beam whereby only the isotope of interest is activated by the laser beam. The apparatus further includes means for producing a collimated and high intensity beam of electrons of narrow energy distribution within the magnetic field which is aimed so as to strike the atomic beam while the atomic beam is simultaneously struck by the laser beam and at an energy level selected to ionize the activated isotope of interest but not ground state species included therewith. Deflection means are disposed in the usual manner to collect the ions.

Trajmar, Sandor↗