Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A 90 GHz Amplifier Assembled Using Flip-Chip Technology

This letter reports the performance of a novel single-stage W-band amplifier fabricated utilizing flip-chip bump-bonding. We have bump-bonded a high-speed, low-noise InP high electron mobility transistor (HEMT) device onto a separately fabricated passive circuit having a GaAs substrate.

FET amplifiers Millimeter wave FETs bump-bonding m↗

Pocket ECG electrode

A low-noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free-ranging subject. The electrode comprises a pocket-shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, Gordon F.↗

Forward sweep, low noise rotor blade

A forward-swept, low-noise rotor blade includes an inboard section, an aft-swept section and a forward-swept outboard section. The rotor blade reduces the noise of rotorcraft, including both standard helicopters and advanced systems such as tiltrotors. The primary noise reduction feature is the forward sweep of the planform over a large portion of the outer blade radius. The rotor blade also includes an aft-swept section. The purpose of the aft-swept region is to provide a partial balance to pitching moments produced by the outboard forward-swept portion of the blade. The rotor blade has a constant chord width; or has a chord width which decreases linearly along the entire blade span; or combines constant and decreasing chord widths, wherein the blade is of constant chord width from the blade root to a certain location on the rotor blade, then decreases linearly to the blade tip thereafter. The noise source showing maximum noise reduction is blade-vortex interaction (BVI) noise. Also reduced are thickness, noise, high speed impulsive noise, cabin vibration and loading noise.

Brooks, Thomas F.↗

Solid-state Image Sensor with Focal-plane Digital Photon-counting Pixel Array

A solid-state focal-plane imaging system comprises an NxN array of high gain. low-noise unit cells. each unit cell being connected to a different one of photovoltaic detector diodes, one for each unit cell, interspersed in the array for ultra low level image detection and a plurality of digital counters coupled to the outputs of the unit cell by a multiplexer(either a separate counter for each unit cell or a row of N of counters time shared with N rows of digital counters). Each unit cell includes two self-biasing cascode amplifiers in cascade for a high charge-to-voltage conversion gain (greater than 1mV/e(-)) and an electronic switch to reset input capacitance to a reference potential in order to be able to discriminate detection of an incident photon by the photoelectron (e(-))generated in the detector diode at the input of the first cascode amplifier in order to count incident photons individually in a digital counter connected to the output of the second cascade amplifier. Reseting the input capacitance and initiating self-biasing of the amplifiers occurs every clock cycle of an integratng period to enable ultralow light level image detection by the may of photovoltaic detector diodes under such ultralow light level conditions that the photon flux will statistically provide only a single photon at a time incident on anyone detector diode during any clock cycle.

Fossum, Eric R.↗

The Canadian Galactic Emission Mapper (CGEM) A Cosmic Microwave Foreground Experiment

The Canadian Galactic Emission Mapper (CGEM) is a 4-meter single-dish radio telescope located at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, Canada. CGEM is designed to map polarized Galactic synchrotron emission across the entire northern sky at 8-10 GHz with 1 MHz frequency resolution and ∼ 0.5 degree angular resolution. Its goal is to obtain high-fidelity, low-noise maps of polarized Galactic synchrotron radiation, at frequencies where synchrotron dominates, in order to provide a reliable template for CMB B−mode foreground cleaning. We will show on sky performance of CGEM’s single-pixel azimuthally-symmetric telescope, its coherent, dual-polarized radiometer, and show maps made from commissioning data from the first few months of operation.

Cosmic microwave background↗

Automating Sensor Characterization with Bayesian Optimization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert's time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Cuevas-Zepeda, Julian [Chicago U., KICP; Chicago U↗

SPT-3G D1: Compton-$y$ maps using data from the SPT-3G and Planck surveys

We present thermal Sunyaev-Zel'dovich (tSZ) Compton-$y$ parameter maps constructed from two years (2019-2020) of observations with the South Pole Telescope (SPT) third-generation camera, SPT-3G, combined with data from the Planck satellite. Using a linear combination (LC) pipeline, we obtain a suite of reconstructions that explore different trade-offs between statistical sensitivity and suppression of astrophysical contaminants, including minimum-variance, CMB-deprojected, and CIB-deprojected $y$-maps. We validate these maps through different statistical techniques such as auto- and cross-power spectra with large-scale structure tracers as well as stacking on cluster locations. These tests are used to understand the balance between noise and astrophysical foreground residuals (such as the CIB) in combination with the recovery of the tSZ signal for different maps. For example, results from stacking at the location of clusters confirm the robustness of the recovered tSZ signal over the $\sim 1500\: {\rm deg}^2$ SPT-3G survey field used in this analysis. The high-resolution and low-noise maps produced here provide an important cosmological tool for future studies, including measurements of the Compton-$y$ map power spectrum, cross-correlations with other tracers of the large-scale structure, detailed modeling of cluster pressure profiles, and study of the thermodynamic state of the baryons in the Universe.

Maniyar, A. S. [Harvard-Smithsonian Ctr. Astrophys↗

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila↗

Alcock-Paczynski Blinding Scheme for the Ly-$α$ Forest Analysis

We present and validate a blinding method for the Lyman-$α$ (Ly$α$) forest analysis based on a modification of the Alcock-Paczynski test. In order to hide the background expansion history, the method employs a geometrical shift of each quasar (QSO) forest in wavelength space, once the quasar continuum has been fitted and the fluctuation field is extracted. The redshift positions for the QSO sample are also changed in a consistent manner. We show that the method remains effective when applied to real data, where contamination from metals and Lyman-$β$ is intrinsically mixed with the Lyman-$α$ forest. This limitation is primarily visible in the 1D correlation function, where other blinding strategies can mitigate the effect. To assess its effectiveness, the prescription is tested against a series of datasets of increasing complexity: from idealized low-noise mocks, to realistic DESI year one synthetic datasets, and finally to data from DESI first data release (DR1), using both the auto (Ly$α\times$Ly$α$) and cross (Ly$α\times$ QSO) correlations. We find that the method robustly shifts the BAO peak position from the 3D correlation functions to the expected value for cosmology changes of around 5% in the matter content, without altering the shape of the posteriors in the model parameters. In conclusion, this catalog-level blinding strategy is a viable method for cosmological inference with the Lyman-$α$ forest, particularly if a cross-analysis with other tracers using the same blinding strategy is pursued.

Perez-Sanchez, G. [Guanajuato U.] (ORCID:000900096↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Cryogenic MMIC Low Noise Amplifiers

Monolithic (MMIC) and discrete transistor (MIC) low noise amplifiers are compared on the basis of performance, cost, and reliability. The need for cryogenic LNA's for future large microwave arrays for radio astronomy is briefly discussed and data is presented on a prototype LNA for the 1 to 10 GZH range along with a very wideband LNA for the 1 to 60 GHz range.

MMIC Low-noise amplifier↗