EASY-SHIFT v Alpha

The software is a generic, price- and load-responsive control algorithm integrating heat pumps with thermal energy storage. The algorithm leverages simple models of the system and easily accessible data to schedule operation of heat pumps and thermal energy storage in ways that minimize the cost of operating the heating/cooling system. This tool is specifically designed to be easy to interact with, and something that industry partners are able to adopt. There are two current state of the art approaches. Industry tends to develop very simple algorithms, with predetermined schedules that are not capable of changing operation in response to changes in operating environment. For example, a control designed to avoid high-price electricity from 5-8 PM will not be able to adapt if the high-price period changes to 4-9 PM. Academia commonly develops algorithms called Model predictive control (MPC). MPC requires extensive data and highly trained staff to develop a specific type of simulation model of the building, connect the building to optimization algorithms, and leverage powerful computers. Industry, with limited time/finance budgets for any project, is resistant to adopting MPC due to the associated high complexity and cost.

Grant, Peter [Lawrence Berkeley National Laborator↗

Advanced Distillation Final Report

The Advanced Distillation project was concluded on December 31, 2009. This U.S. Department of Energy (DOE) funded project was completed successfully and within budget during a timeline approved by DOE project managers, which included a one year extension to the initial ending date. The subject technology, Microchannel Process Technology (MPT) distillation, was expected to provide both capital and operating cost savings compared to conventional distillation technology. With efforts from Velocys and its project partners, MPT distillation was successfully demonstrated at a laboratory scale and its energy savings potential was calculated. While many objectives established at the beginning of the project were met, the project was only partially successful. At the conclusion, it appears that MPT distillation is not a good fit for the targeted separation of ethane and ethylene in large-scale ethylene production facilities, as greater advantages were seen for smaller scale distillations. Early in the project, work involved flowsheet analyses to discern the economic viability of ethane-ethylene MPT distillation and develop strategies for maximizing its impact on the economics of the process. This study confirmed that through modification to standard operating processes, MPT can enable net energy savings in excess of 20%. This advantage was used by ABB Lumus to determine the potential impact of MPT distillation on the ethane-ethylene market. The study indicated that a substantial market exists if the energy saving could be realized and if installed capital cost of MPT distillation was on par or less than conventional technology. Unfortunately, it was determined that the large number of MPT distillation units needed to perform ethane-ethylene separation for world-scale ethylene facilities, makes the targeted separation a poor fit for the technology in this application at the current state of manufacturing costs. Over the course of the project, distillation experiments were performed with the targeted mixture, ethane-ethylene, as well as with analogous low relative volatility systems: cyclohexane-hexane and cyclopentane-pentane. Devices and test stands were specifically designed for these efforts. Development progressed from experiments and models considering sections of a full scale device to the design, fabrication, and operation of a single-channel distillation unit with integrated heat transfer. Throughout the project, analytical and numerical models and Computational Fluid Dynamics (CFD) simulations were validated with experiments in the process of developing this platform technology. Experimental trials demonstrated steady and controllable distillation for a variety of process conditions. Values of Height-to-an-Equivalent Theoretical Plate (HETP) ranging from less than 0.5 inch to a few inches were experimentally proven, demonstrating a ten-fold performance enhancement relative to conventional distillation. This improvement, while substantial, is not sufficient for MPT distillation to displace very large scale distillation trains. Fortunately, parallel efforts in the area of business development have yielded other applications for MPT distillation, including smaller scale separations that benefit from the flowsheet flexibility offered by the technology. Talks with multiple potential partners are underway. Their outcome will also help determine the path ahead for MPT distillation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Building America Technology and Energy Savings Analysis of Two 2,721 ft 2 Homes in a Mixed Humid Climate

The ZEBRAlliance is an opportunity to accelerate progress toward DOE’s goal of maximizing cost-effective energy efficiency by investing in a highly leveraged, focused effort to test new high-efficiency components emerging from Oak Ridge National Laboratory’s (ORNL) Cooperative Research and Development Agreement (CRADA) partners and others. The Alliance integrated efficient components into the construction of four research houses that will be used as test markets to gauge the success of the components and houses. These four research houses are expected to be the first houses used to field-test several newly emerging products such as the ClimateMaster ground-source integrated heat pump. When these new components are proven, they will become available to serve regional and national homebuilding markets. Some of these products will impact existing housing retrofit markets as well as new construction. These four houses demonstrate different strategies for saving energy, but all are about 55-60% more efficient than traditional new construction (based on third party certified HERS evaluations). After the research period, the houses will be sold to interested home buyers. The outcome will contribute to efforts by TVA to defer 1,400 MW of new electricity generation and reduce growth in energy consumption by 4.3 million MWh per year by 2012, and in the longer term, to transform how homes are built and retrofitted for improved energy efficiency in the Tennessee Valley.

Jackson, Roderick K.↗

Oxy-Combustion System Process Optimization

The overall objective of this work is to develop a new chemical absorbent-based, high pressure, CO 2 purification system to remove the residual oxygen that currently contaminates the recovered CO 2 , and to optimize the Pressurized Oxy-Combustion (POxC) process to minimize the Cost of Electricity (COE) generated in this advanced combustion process. TDA developed and validated the performance of the oxygen removal system for CO 2 purification. In collaboration with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI), we optimized the POxC process, including thermal management, heat integration, and power cycle optimization using process design and modeling supported with Aspen Plus® process simulations. The techno-economic analysis results indicate that the pressurized oxycombustion coal power plant with Ion-transport membrane (ITM) air separation unit (ASU) (Case 2 – 30.55%) does not show an advantage over a cryogenic ASU (Case 1 – 31.24%) while TDA’s sorption-based ASU (Case 4 - 32.61%) shows a significant advantage over the cryogenic ASU (Case 1 – 331.24%). The specific plant costs show a wide range with a low of $2544/kW for Case 11C (TDA ASU, co-sequestering the SO x , and ultra-supercritical steam cycle) to a high of $2975/kW for Case 12A (cryogenic ASU and sCO 2 cycle). In general, the ITM ASU based cases have lower specific plant costs than the corresponding cryogenic ASU based cases while the TDA ASU based cases show the lowest specific plant costs. The main reason for lowering these costs is the higher overall plant thermal efficiency which decreases the plant cost on a $ per kW basis. Next comparing the cases with different power cycle working fluid conditions in terms of temperature and pressure while all utilizing steam, similar trends as the plant costs may be observed. However, with the supercritical CO 2 (sCO 2 ) cycle, the increase in thermal efficiency of the sCO 2 cycle was not able to offset its increase in plant cost making the plant costs higher than those of the corresponding steam cycle cases. The Cost of Electricity (COE) again shows similar trends as the specific plant costs. The COE for Case 11C at $110.1/MWh is also the lowest, but among all cases that do not co-sequester the SO x , Case 12C (TDA ASU and sCO 2 cycle) has the lowest COE at $\$$117.5/MWh while the highest is for Case 8A (cryogenic ASU and supercritical steam cycle) at $130.4/MWh.

20 FOSSIL-FUELED POWER PLANTS↗

Steady-State Comparison of GS-IHP Field Data to Modeled Performance

Field tests were conducted over the winter and summer of 2011 on a prototype (ground-source integrated heat pump (GS-IHP) in Oak Ridge, TN. The extensive field test data was filtered to provide a subset of near-steady-state operation data suitable for comparison to modeled steadystate performance. On-site power use characteristics of the compressor, blower, and pumps and other operational measurements were used to calibrate the system model. Comparisons were made for four modes of operation: space heating, dedicated water heating, space cooling, and combined space cooling and water heating. Analysis results suggest that the field unit was undercharged, especially in the combined space cooling and water heating mode. The fully calibrated model agreed on average to within 2% on capacity, power, and COP/EER for the space heating and cooling modes. Average differences were larger for the water heating modes, ranging from 3 to 11%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Post-Combustion CO 2 Capture through Increased Mass Transfer and Lower Degradation

The over-arching goal of the proposed project is to develop three techniques to enable aqueous post-combustion CO 2 capture technologies to meet the DOE performance and cost targets of 90% CO 2 capture, 95% purity, at a cost of less than $30/tonne CO 2 captured. This will be accomplished by the development of materials and processes to increase mass transfer in the absorber and reduce the environmental impacts. While constantly working to reduce the cost of CO 2 capture via solvent development and process & heat integration, increasing CO 2 mass transfer through development of custom dynamic packing materials and tuning solvent physical properties may offer a route to increased solvent capacity, lower energy consumption and reduced aerosol formation. The environmental concerns that have been identified in amine-based CO 2 capture systems, nitrosamines specifically, are another critical element that will be addressed in this project. The specific objectives of the project were to: 1) conduct detailed studies to understand how solvent physical properties and aerosol formation are impacted by additives; 2) quantify the CO 2 mass transfer improvement from the dynamic polarity packing in the absorber and the additive-modified solvent using the existing UK bench-scale CO 2 capture unit; 3) quantify the energy consumption savings associated with enhanced mass transfer; 4) quantify the benefits of the UK’s electrochemical cell to decompose nitrosamines; and 5) collect the necessary information/data to conduct a high-level TEA assessment of the proposed technologies. The project involved the fabrication and installation of customized dynamic polarity packing and an investigation into the understanding of the impact of chemical additives on solvent properties to increase CO 2 mass transfer in the absorber column, and lastly the design of an electrochemical cell to decompose nitrosamines in a water wash. After both systems were fabricated, they were tested at UK facilities, including on the bench-scale CO 2 capture unit under parametric and long-term operation.

20 FOSSIL-FUELED POWER PLANTS↗

Demonstration of a Continuous Motion Direct Air Capture System

Global Thermostat (GT) has developed a process that addresses the primary technical challenges associated with direct air capture (DAC): the ability to process enormous volumetric flowrates of air and provide the energy for regeneration at acceptable cost. However, at current, there is opportunity for improvement in overall capture costs and especially in capital costs. While GT has advanced its base technology to TRL levels supporting commercial deployments, its research strategy includes alternative technology embodiments that enable substantial reductions in the cost per tonne of CO 2 removed. The objective of this project is to advance the most promising of these embodiments, where a DAC plant is operated in a continuous fashion rather than a discrete stepwise fashion (GT’s commercial scale technology approach). The Continuous Motion Direct Air Capture (cDAC) System’s advantages over the GT baseline stepwise DAC platform have been proposed primarily as a reduction in the complexity required for starting and stopping a movement system, relaxing requirements for other components designed for a rapid switching application, and a flattening of the sharp instantaneous fluid flowrates into steady-state mass & energy flows to enable smoother operation and easier heat integration. These advantages can lead to shorter cycle times, greater plant reliability, and lower capital expense. The primary objective of this project is the design, construction, commissioning, and operation of a field-test unit (FTU) at a scale in the range of ~200 tons CO 2 per year. Data generated from the operation campaign would then be used in a prescreening techno-economic analysis (TEA) and life cycle analysis (LCA), allowing this process to be compared to other carbon capture technologies.

42 ENGINEERING↗

Development of High-Efficiency Low-Lift Vapor Compression System - Final Report

PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beneficial Reuse of Industrial CO2 Emissions Using a Microalgae Photobioreactor: Waste Heat Utilization Assessment

Microalgae are a potential means of recycling CO2 from industrial point sources. With this in mind, a novel photobioreactor (PBR) was designed and deployed at a coal-fired power plant. To ascertain the feasibility of using waste heat from the power plant to heat algae cultures during cold periods, two heat transfer models were constructed to quantify PBR cooling times. The first, which was based on tabulated data, material properties and the physical orientation of the PBR tubes, yielded a range of heat transfer coefficients of 19–64 W m−2 K−1 for the PBR at wind speeds of 1–10 m s−1. The second model was based on data collected from the PBR and gave an overall heat transfer coefficient of 24.8 W m−2 K−1. Energy penalties associated with waste heat utilization were found to incur an 18%–103% increase in energy consumption, resulting in a 22%–70% reduction in CO2 capture for the scenarios considered. A techno-economic analysis showed that the cost of heat integration equipment increased capital expenditures (CAPEX) by a factor of nine and increased biomass production costs by a factor of three. Although the scenario is thermodynamically feasible, the increase in CAPEX incurs an increase in biomass production cost that is economically untenable.

Mohler, Daniel T.↗

Development and Characterization of CPI Surface Insulation

A new type of reusable surface material that could find application as a component of the thermal protection system of the space shuttle orbiter is discussed. These materials consist of 20-30% dense closed cell high emittance glass ceramic foams formulated by sintering an intimate mixture of fly ash cenospheres with 4-12 wt % cobalt oxide. These unique ceramic foams exhibit: (1) High mechanical strengths; (2) no need for waterproof coating due to the non-interconnecting cell network; (3) high emissivities; (4) ability to withstand space shuttle thermal environments with no loss of reuse capability; and (5) a machinable ceramic with capability of maintaining the close tolerances required of an integrated heat shield system.

Tobin, A.↗

Aerobraking techniques for planetary missions

Aerobraking techniques are applied to trajectory design for the VOIR (Venus Orbiting Imaging Radar) mission to enhance overall mission performance. The approach can be used for other planetary missions such as a Titan orbiter or a Mars sample return to earth. The orientation of the elliptical insertion orbit must be chosen in such a way that the combined effects of solar gravity, central-body harmonics, and drag on periapsis altitude are minimized to avoid frequent maneuvers. The selection of the base and width of a corridor for periapsis altitude depends upon the temperature and integrated heat of the aerobrake shield, the atmospheric density profile, the duration of aerobraking, the number of maneuvers, the time available between maneuvers, and uncertainties in the central-body gravity field and atmospheric density. Flight path profiles for an aerodynamically stable spacecraft and an inertially fixed spacecraft passing through the free molecular flow regime, as well as the transitional flow regime, are illustrated

Tang, C. C. H.↗

High-efficiency V-band GaAs IMPATT diodes

Double-drift GaAs IMPATT diodes were designed for V-band frequency operations and fabricated using molecular-beam epitaxy. The diodes were fabricated in two configurations: (1) circular mesa diodes with silver-plated (integrated) heat sinks: (2) pill-type diodes bonded to diamond heat sinks. Both configurations utilized a miniature quartz-ring package. Output power greater than 1 W CW was achieved at V-band frequencies from diodes on diamond heat sinks. The best conversion efficiency was 13.3 percent at 55.5 GHz with 1 W output power.

Ma, Y. E.↗

Solar wind halo electrons from 1-4 AU

Observations from the Ulysses solar wind electron spectrometer are used to make a first examination of the evolution of the solar wind suprathermal or halo electron population as a function of heliocentric distance beyond 1 AU. As the core population cools with increasing heliocentric distance, no gap is formed between the core and halo populations. Rather, the halo electrons extend to increasingly lower energies. As predicted previously on theoretical grounds, the ratio of the core electron temperature to the low energy cutoff of the halo population appears to be roughly constant with a value of about 7.5. The total integrated heat flux drops rapidly with increasing heliocentric distance; a best fit power law of R exp -2.36 is found. In addition, it is found that the ratio of the halo to core densities is roughly constant over heliocentric distance with the halo representing 4 percent of the total electron distribution. These results suggest that the halo population may not consist of truly noninteractive test particles over the heliocentric range of 1-4 AU.

Mccomas, D. J.↗

January and July global distributions of atmospheric heating for 1986, 1987, and 1988

Three-dimensional global distributions of atmospheric heating are estimated for January and July of the 3-year period 1986-88 from the European Center for Medium Weather Forecasts (ECMWF) Tropical Ocean Global Atmosphere (TOGA) assimilated datasets. Emphasis is placed on the interseasonal and interannual variability of heating both locally and regionally. Large fluctuations in the magnitude of heating and the disposition of maxima/minima in the Tropics occur over the 3-year period. This variability, which is largely in accord with anomalous precipitation expected during the El Nino-Southern Oscillation (ENSO) cycle, appears realistic. In both January and July, interannual differences of 1.0-1.5 K/day in the vertically averaged heating occur over the tropical Pacific. These interannual regional differences are substantial in comparison with maximum monthly averaged heating rates of 2.0-2.5 K/day. In the extratropics, the most prominent interannual variability occurs along the wintertime North Atlantic cyclone track. Vertical profiles of heating from selected regions also reveal large interannual variability. Clearly evident is the modulation of the heating within tropical regions of deep moist convection associated with the evolution of the ENSO cycle. The heating integrated over continental and oceanic basins emphasizes the impact of land and ocean surfaces on atmospheric energy balance and depicts marked interseasonal and interannual large-scale variability.

Schaack, Todd K.↗

Navigation Strategy for the Mars 2001 Lander Mission

The Mars Surveyor Program (MSP) is an ongoing series of missions designed to robotically study, map and search for signs of life on the planet Mars. The MSP 2001 project will advance the effort by sending an orbiter, a lander and a rover to the red planet in the 2001 opportunity. Each vehicle will carry a science payload that will Investigate the Martian environment on both a global and on a local scale. Although this mission will not directly search for signs of life, or cache samples to be returned to Earth, it will demonstrate certain enabling technologies that will be utilized by the future Mars Sample Return missions. One technology that is needed for the Sample Return mission is the capability to place a vehicle on the surface within several kilometers of the targeted landing site. The MSP'01 Lander will take the first major step towards this type of precision landing at Mars. Significant reduction of the landed footprint will be achieved through two technology advances. The first, and most dramatic, is hypersonic aeromaneuvering; the second is improved approach navigation. As a result, the guided entry will produce in a footprint that is only tens of kilometers, which is an order of magnitude improvement over the Pathfinder and Mars Polar Lander ballistic entries. This reduction will significantly enhance scientific return by enabling the potential selection of otherwise unreachable landing sites with unique geologic interest and public appeal. A landed footprint reduction from hundreds to tens of kilometers is also a milestone on the path towards human exploration of Mars, where the desire is to place multiple vehicles within several hundred meters of the planned landing site. Hypersonic aeromaneuvering is an extension of the atmospheric flight goals of the previous landed missions, Pathfinder and Mars Polar Lander (MPL), that utilizes aerodynamic lift and an autonomous guidance algorithm while in the upper atmosphere. The onboard guidance algorithm will control the direction of the lift vector, via bank angle modulation, to keep the vehicle on the desired trajectory. While numerous autonomous guidance algorithms have been developed for use during hypersonic flight at Earth, this will be the first flight of an autonomously directed lifting entry vehicle at Mars. However, without sufficient control and knowledge of the atmospheric entry conditions, the guidance algorithm will not perform effectively. The goal of the interplanetary navigation strategy is to deliver the spacecraft to the desired entry condition with sufficient accuracy and knowledge to enable satisfactory guidance algorithm performance. Specifically, the entry flight path angle must not exceed 0.27 deg. to a 3 sigma confidence level. Entry errors will contribute directly to the size of the landed footprint and the most significant component is entry flight path angle. The size of the entry corridor is limited on the shallow side by integrated heating constraints, and on the steep side by deceleration (g-load) and terminal descent propellant. In order to meet this tight constraint it is necessary to place a targeting maneuver seven hours prior to the time of entry. At this time the trajectory knowledge will be quite accurate, and the effects of maneuver execution errors will be small. The drawback is that entry accuracy is dependent on the success of this final late maneuver. Because propulsive maneuvers are critical events, it is desirable to minimize their occurrence and provide the flight team with as much response time as possible in the event of a spacecraft fault. A mission critical maneuver at Entry - 7 hours does not provide much fault tolerance, and it is desirable to provide a strategy that minimizes reliance on this maneuver. This paper will focus on the Improvements in interplanetary navigation that will decrease entry errors and will reduce the landed footprint, even in the absence of aeromaneuvering. The easiest to take advantage of are Improvements In the knowledge of the Mars ephemeris and gravity field due to the MGS and MSP'98 missions. Improvements In data collection and reduction techniques such as "precislon ranging' and near-simultaneous tracking will also be utilized. In addition to precise trajectory control, a robust strategy for communications and flight operations must also be demonstrated. The result Is a navigation and communications strategy on approach that utilizes optimal maneuver placement to take advantage of trajectory knowledge, minimizes risk for the flight operations team, is responsive to spacecraft hardware limitations, and achieves the entry corridor. The MSP2001 mission Is managed at JPL under the auspices of the Mars Exploration Directorate. The spacecraft flight elements are built and managed by Lockheed-Martin Astronautics in Denver, Colorado.

Mase, Robert A.↗

Solutions for Hot Situations

From the company that brought the world an integral heating and cooling food service system after originally developing it for NASA's Apollo Program, comes yet another orbital offshoot: a product that can be as thin as paper and as strong as steel. Nextel Ceramic Textiles and Composites from 3M Company offer space-age protection and innovative solutions for hot situations, ranging from NASA to NASCAR. With superior thermal protection, Nextel fabrics, tape, and sleevings outperform other high temperature textiles such as aramids, carbon, glass, and quartz, permitting engineers and manufacturers to handle applications up to 2,500 F (1,371 C). The stiffness and strength of Nextel Continuous Ceramic Fibers make them a great match for improving the rigidity of aluminum in metal matrix composites. Moreover, the fibers demonstrate low shrinkage at operating temperatures, which allow for the manufacturing of a dimensionally stable product. These novel fibers also offer excellent chemical resistance, low thermal conductivity, thermal shock resistance, low porosity, and unique electrical properties.

Source record↗

Thought for Food

Key to the integral heating system's efficiency is the "dish-oven", which doubles as a heating unit and serving plate. The dish-oven consists of a sealing frame (top) a plastic outer shell (center) and the ceramic inner dish. A special coating on the bottom of the inner dish transforms electrical impulses into heat

Source record↗

Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring

A document describes the fabrication of a two-dimensional microcalorimeter array that uses microstrip wiring and integrated heat sinking to enable use of high-performance pixel designs at kilopixel scales (32 X 32). Each pixel is the high-resolution design employed in small-array test devices, which consist of a Mo/Au TES (transition edge sensor) on a silicon nitride membrane and an electroplated Bi/Au absorber. The pixel pitch within the array is 300 microns, where absorbers 290 microns on a side are cantilevered over a silicon support grid with 100-micron-wide beams. The high-density wiring and heat sinking are both carried by the silicon beams to the edge of the array. All pixels are wired out to the array edge. ECR (electron cyclotron resonance) oxide underlayer is deposited underneath the sensor layer. The sensor (TES) layer consists of a superconducting underlayer and a normal metal top layer. If the sensor is deposited at high temperature, the ECR oxide can be vacuum annealed to improve film smoothness and etch characteristics. This process is designed to recover high-resolution, single-pixel x-ray microcalorimeter performance within arrays of arbitrarily large format. The critical current limiting parts of the circuit are designed to have simple interfaces that can be independently verified. The lead-to-TES interface is entirely determined in a single layer that has multiple points of interface to maximize critical current. The lead rails that overlap the TES sensor element contact both the superconducting underlayer and the TES normal metal

Chervenak, James↗