Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting EBW detonator failure using DSC data

Exploding bridgewire detonators (EBWs) containing pentaerythritol tetranitrate (PETN) exposed to high temperatures may not function following discharge of the design electrical firing signal from a charged capacitor. Knowing functionality of these arbitrarily facing EBWs is crucial when making safety assessments of detonators in accidental fires. Orientation effects are only significant when the PETN is partially melted. Here, the melting temperature can be measured with a differential scanning calorimeter. Nonmelting EBWs will be fully functional provided the detonator never exceeds 406 K (133 °C) for at least 1 h. Conversely, EBWs will not be functional once the average input pellet temperature exceeds 414 K (141 °C) for a least 1 min which is long enough to cause the PETN input pellet to completely melt. Functionality of the EBWs at temperatures between 406 and 414 K will depend on orientation and can be predicted using a stratification model for downward facing detonators but is more complex for arbitrary orientations. A conservative rule of thumb would be to assume that the EBWs are fully functional unless the PETN input pellet has completely melted.

42 ENGINEERING↗

Smaller and faster: a review of conventional and nanocalorimetry techniques for determining thermophysical properties of nuclear materials

Thermal analysis of nuclear materials is critical for the advancement of nuclear technology. The heat effects associated with heat capacity, phase transformation, and radiation damage can be measured with conventional calorimeters. However, conventional calorimetric techniques are often restricted in terms of heating rate and sample mass, especially when studying the limited amounts of materials subject to extreme conditions. In this review, we summarize conventional calorimetric studies of critical thermophysical and thermochemical properties of pure actinide metals (U, Np, Am, Pu), fast reactor metallic fuel alloy systems (U–Zr, U–Pu–Zr, Pu–U, Pu–Zr), and actinide oxides that are primary constituents or transmutation products in light water reactor fuel rods (U–O, Np–O, Am–O, Pu–O, Pu–U–O). Adiabatic and drop calorimetry have been the primary techniques used for these studies, however the development of fast scanning calorimetry using micro-electro-mechanical-based systems allows determination of thermodynamic properties from smaller sample masses. We report recent investigations that leverage the fast heating rates of nanocalorimetry by itself or combined with other characterization techniques. Furthermore, we then discuss opportunities for nanocalorimetry to provide solutions to some of the technical challenges inherent in thermal analysis of nuclear materials, namely a reduction in sample activity, emulating heating transients, investigation of phase evolution in irradiated samples, and characterization of radiation damage evolution. Nanocalorimetry has the potential to significantly advance the understanding of thermophysical properties in nuclear materials and thus accelerate the development of nuclear technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ceramic encapsulated metal phase change material for high temperature thermal energy storage

Thermal energy storage (TES) is a broad-based technology for reducing CO₂ emissions and advancing concentrating solar, fossil, and nuclear power through improvements in efficiency and economics. Phase change materials (PCMs) are of interest as TES media because of their ability to store large amounts of heat in relatively small volumes. The volume expansion during a phase change, typically between a solid and liquid, can cause breakage of protective coatings. This paper reports on the fabrication of a ceramic encapsulated metal (CEM) high temperature TES technology using a rotary calcining furnace and a fluidized bed chemical vapor deposition coating technique. Aluminum beads were chosen as the PCM because Al has a high melting point (660 °C), low cost, high heat of fusion, and an ability to form a thin, strong alumina layer capable of supporting the Al melt for subsequent processing. Quite remarkably, this study shows that 1 mm diameter Al can be fluidized up to at least 1500 °C in an appropriate atmosphere while maintaining a spheroid geometry. This allowed for producing a first of a kind CEM whereby Al particles were encapsulated in pyro-carbon (PyC) and high purity, dense chemical vapor deposited SiC. The CEM with a PyC only coating was exposed to thermal cycling to test the performance with a differential scanning calorimeter; the melting point and latent heat were measured to be 648.4 ± 2.8 °C and 293.3 ± 6.2 J/g respectively. It was demonstrated that the CEM design is possible to produce, laying the foundation for manufacturing of high temperature, tunable, TES media.

25 ENERGY STORAGE↗

Silicon alloying enhances fast heating rate combustion of aluminum particles

Alloys and composites of aluminum (Al) have shown promise in regulating and enhancing particle combustion for energy generation applications. Recent work on aluminum-silicon (Al-Si) spherical alloy particles has shown improved combustion at low heating rates through enhanced diffusion accompanying a lower melting temperature. This study extends reactivity analysis to higher heating rates, comparing oxidation of Al-Si with Al. Flame speeds of Al-Si powder mixed with molybdenum trioxide (MoO 3 ) powder (Al-Si+MoO 3 ) exhibited a faster transition to steady propagation relative to Al+MoO 3 . Bomb calorimetry experiments revealed up to 5.8% greater early temperature rise for Al-Si powder. Rapid steady propagation for Al-Si mixture and faster temperature rise for Al-Si particles were attributed to accelerated kinetics evidenced in thermal equilibrium analysis of the mixtures using a differential scanning calorimeter (DSC). Larger DSC exotherms in the early stages of oxidation (i.e., 480–720 °C) correlated with early heat release and promoted steady flame propagation for Al-Si+MoO 3 compared with Al+MoO 3 . Furthermore, in multiple heating rate DSC studies, Al-Si+MoO 3 ignited at a lower heating rate (i.e., 15 ⁰C/min) than Al+MoO 3 (i.e., 20 ⁰C/min). Both mixtures ignited at temperatures less than 625 °C which is above the melting temperature of Al-Si (574 °C) and below Al (659 °C). Thus, alloy particle fuels with enhanced diffusion-controlled kinetics promote steady flame propagation and show promise for energy generation applications. This is especially promising for technologies driven by enhanced condensed phase combustion such as some propellant additives or applications dependent on reliable burn rates such as pyrotechnic time delay formulations and primers.

36 MATERIALS SCIENCE↗

Hydrothermal liquefaction of Cyanidioschyzon merolae and Salicornia bigelovii Torr.: The interaction effect on product distribution and chemistry

Hydrothermal liquefaction (HTL) has proven to be a promising technology for processing wet biomass into valuable biofuel intermediates. We investigated the influence of HTL process parameters on the individual and co-liquefaction of Salicornia bigelovii Torr. (SL) and Cyanidioschyzon merolae (CM) biomass and their respective product properties and characteristics. SL and CM biomasses were subjected to HTL conditions of process temperatures (250–350 °C), 10 wt% solid loading, 30 min reaction time, and co-liquefaction ratios (80–20, 50–50, 20–80, CM-SL, respectively). The individual maximum HTL biocrude yields for CM (34.63 wt%) and SL (7.63 wt%) were obtained at 300 °C. In both cases, biocrude oils had a higher carbon and hydrogen content relative to those of the original biomass. The HHV (higher heating value) values for the biocrude samples ranged from 24.2 to 33.12 MJ/kg, which were significantly higher than those of the original biomasses. A positive synergistic effect was observed during the co-liquefaction of two biomasses, where the experimental yield of biocrude oil was higher than the theoretical value. During the co-liquefaction experiments, a maximum biocrude yield of 32.95 wt% was obtained at 300 °C and 80–20 CM-SL biomass mix ratio. Co-liquefaction led to an increase in the energy content of the co-liquefied biocrude oil and a higher energy recovery rate. Finally, the properties of HTL products and biomasses were determined with TGA, CHN elemental analyzer, GC/MS, bomb calorimeter, HACH Spectrophotometer, and ICP OES.

09 BIOMASS FUELS↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Effect of 60 Co γ-radiation on the tetrafluoroethylene/perfluoro(methyl vinyl ether) copolymer

The chemical and paramagnetic composition of the surface of the tetrafluoroethylene / perfluoro(methyl vinyl ether) copolymer (MFA) was investigated before and after γ-irradiation. The content of fluorine and carbon decreases at radiolysis of MFA, as well as the proportion of oxygen increases as a result of the oxidation reaction of radicals formed during γ-irradiation. The electron paramagnetic resonance (EPR) spectrum of the copolymer irradiated at 77 K contains the radicals ~CF 2 C∙FCF 2 ~ (1) and >CFOC∙F 2 (2). The absence of ~CF 2 C∙F 2 radicals, which can be formed at radiolytic rupture of the C—C bond of the copolymer main chain is associated with the effect of recombination of the resulting radical pair. The EPR spectrum of irradiated MFA at 300 K only recorded radical (1), which transform into peroxide radicals when air oxygen is introduced into the irradiated sample. Thermomechanical curves of native and radiolyzed MFA show three structural states of the amorphous block (glass, transition region, plateau of highly elastic deformation), as well as melting and molecular flow of the copolymer. The radio thermoluminescence curve shows five maxima associated with the emission of light during the recombination of stabilized ions and radicals during heating of the pre-irradiated MFA at 77 K. The temperature of the luminescence peak maximum at 336 K is close to the temperature of the onset of the devitrification of the chains of the amorphous block of MFA on the thermomechanical curve at 341 K. Irradiation leads to an increase in crystallinity of MFA. The heat of fusion of irradiated MFA on the Differential Scanning Calorimeter (DSC) curve is 50 % higher than the fusion heat of native copolymer. During the heating of γ-irradiated MFA, the relative content of COF molecules in the thermal decomposition products increases by an order of magnitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of polyacrylonitrile/ionic covalent organic framework hybrid nanofibers for effective removal of chromium(VI) from water

Hexavalent Cr(VI) found in industrial wastewater is a proven carcinogen which causes serious health issues in humans around the world. This study presents a novel method to enhance the Cr(VI) oxyanion removal from wastewater by polyacrylonitrile (PAN) nanofibers through incorporation of a guanidinium-based ionic covalent organic framework (BT-DG) in the nanofibers structure. In this work, simple electrospinning technique was employed to produce PAN nanofibers and BT-DG was synthesized through condensation between benzene-1,3,5-tricarbaldehyde and N,N'-diaminoguanidine monohydrochloride. In-situ polymerization of BT-DG onto PAN nanofibers resulted in generation of hybrid PAN-BT-DG nanofibers. This modified PAN-BT-DG was characterized by obtaining its point of zero charge (PZC), differential scanning calorimeter (DSC), scanning electron microscopy (SEM) morphology and surface elements and oxidation states by X-ray photoelectron spectroscopy (XPS). PAN-BT-DG exhibited positive surface charge below pH 4, making it an outstanding adsorbent, for Cr(VI) removal. Cr(VI) adsorption onto PAN-BT-DG followed pseudo second order kinetics and adsorption data fitted well to Freundlich isotherm model. Highest Cr(VI) removal was obtained at 55 °C with a maximum Langmuir adsorption capacity of 173 mg/g at pH 3. Kinetic studies revealed that Cr(VI) adsorption onto PAN-BT-DG is endothermic and thermodynamically feasible. Desorption studies were conducted on PAN-BT-DG using 1 M NaOH as the stripping solvent and PAN-BT-DG exhibited excellent regeneration after five consecutive cycles.

36 MATERIALS SCIENCE↗

Glass transition temperature studies of planetary ball milled glasses: Accessing the rapidly cooled glassy state in Na 4 P 2 S 7-x O x , 0 ≤ x ≤ 7, Oxy-thio phosphate glasses

This paper details the very first in-depth study of the glass transition temperature (T g ) for planetary balled milled (PBM) Na 4 P 2 S 7-x O x (NaPSO), where 0 ≤ x ≤ 7, glasses. For 0 ≤ x ≤ 5, fully amorphous, homogeneous, and chemically reacted compositions can be prepared. For samples with 5 < x ≤ 7, partially amorphous but fully chemically reacted glass-ceramics can be produced. The reproducible, thermally cyclable onset T g and the onset crystallization temperature, T c , were investigated as a function of the composition and of the short-range order (SRO) structures of the glasses. Additionally, we examined the extreme sub-T g exothermic relaxations present due to the high energy milling processing and correspondingly high effective quenching rate. Using a differential scanning calorimeter (DSC) and scanning from well below the onset T g , the glasses are observed to relax exothermally below T g . The integrated relaxation enthalpy, ΔH rel , is ~ 0 for the x = 2 glass, but is significantly exothermic for lower and higher values of x. Once the high fictive state of these glasses has been erased by scanning to above the T g , but below the T c of the glass, the DSC scans of the glasses recover normal behavior for a normally cooled glass without any relaxation exotherm. The T g s of these glasses remain relatively constant for 0 ≤ x ≤ 3, but for glasses with 3 < x ≤ 5, T g increases sharply following the combined effects of the phosphate chain length increasing caused by the formation of bridging oxygens and the increasing concentration of more charge dense non-bridging oxygens (NBOs). For x > 5, both T g and Tc decrease sharply, becoming nearly identical at x = 7 where glass formation essentially ceases. For smaller values of x, T c increases with both chain length and the structural complexity of the composition but decreases sharply for glass-ceramics of x > 5.

36 MATERIALS SCIENCE↗

Calorimetry can detect the early onset of hydrolysis in hybrid supercapacitors with aqueous electrolytes

This study investigates the effect of cation species on the onset of electrolyte hydrolysis in hybrid supercapacitors with aqueous electrolytes using isothermal operando calorimetry. The cells consisted of a positive α-MnO 2 cryptomelane electrode and a negative activated carbon (AC) electrode with either 0.5 M K 2 SO 4 or 0.5 M Cs 2 SO 4 aqueous electrolytes. They were characterized using cyclic voltammetry and galvanostatic cycling. In addition, the instantaneous heat generation rate at each electrode was measured using a custom isothermal operando calorimeter. Heat generation associated with resistive losses (Joule heating) and reversible ion adsorption/desorption was clearly identified. For larger potential windows, an endothermic dip, attributed to the onset of hydrolysis, was observed at the positive α-MnO 2 electrode where K + and Cs + ions engaged in fast surface redox reactions. Interestingly, this endothermic dip appeared at 1.8 V and 2.0 V for K 2 SO 4 and Cs 2 SO 4 aqueous electrolytes, respectively. The difference in the stable operating potential window was attributed to thinner solvation shell around Cs + cation than for K + thus reducing the amount of water present near the electrodes as ions partially shed their solvation shells during adsorption. The early onset of hydrolysis could be observed by isothermal operando calorimetry before it could be observed with conventional electrochemical methods.

42 ENGINEERING↗

The battery failure databank: Insights from an open-access database of thermal runaway behaviors of Li-ion cells and a resource for benchmarking risks

The thermal response of Li-ion cells can greatly vary for identical cell designs tested under identical conditions, the distribution of which is costly to fully characterize experimentally. The open-source Battery Failure Databank presented here contains robust, high-quality data from hundreds of abuse tests spanning numerous commercial cell designs and testing conditions. Data was gathered using a fractional thermal runaway calorimeter and contains the fractional breakdown of heat and mass that was ejected, as well as high-speed synchrotron radiography of the internal dynamic response of cells during thermal runaway. The distribution of thermal output, mass ejection, and internal response of commercial cells are compared for different abuse-test conditions, which when normalized on a per amp-hour basis show a strong positive correlation between heat output from cells, the fraction of mass ejected from the cells, their energy- and power-density. Ejected mass was shown to contain 10x more heat per gram than non-ejected mass. The causes of 'outlier' thermal and ejection responses i.e., extreme cases, are elucidated by high-speed radiography which showed how occurrences such as vent clogging can create more hazardous conditions. High-speed radiography also demonstrated how the time-resolved interplay of thermal runaway propagation and mass ejection influences the total heat generated.

25 ENERGY STORAGE↗

Thermal runaway mechanism of lithium-ion battery with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode materials

Battery safety is critical to the application of lithium-ion batteries, especially for high energy density battery applied in electric vehicles. In this paper, the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 O 2 based lithium-ion battery is illustrated. And the reaction between cathode and flammable electrolyte is proved as the trigger of the thermal runaway accident. In detail, with differential scanning calorimeter tests for battery components, the material combination contributing to thermal runaway was decoupled. Characterization with synchrotron X-ray diffraction and transmission electron microscopy with in-situ heating proved that the vigorous exothermic reaction is initiated by the liberated oxygen species. The pulse of highly active oxygen species reacted quickly with the electrolyte, accompanied with tremendous heat release, which accelerated the phase transformation of charged cathode. Also, the mechanism is verified by a confirmatory experiment when the highly active oxygen species were trapped by anion receptor, the phase transformation of the charged cathode was inhibited. Clarifying the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 based lithium-ion battery may light the way to battery chemistries of both high energy density and high safety.

25 ENERGY STORAGE↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the data acquisition, trigger, and slow control systems of the Mu2e experiment at Fermilab

The Mu2e experiment at the Fermilab will search for a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10,000 over existing limits. In this work, the Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq framework as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several framework components — an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface to its components through a web browser. Data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read out data from the Mu2e Cosmic Ray Veto system. Foundation of the Mu2e DCS, EPICS – an Experimental Physics and Industrial Control System – is an open-source platform for monitoring, controlling, alarming, and archiving. A prototype of the TDAQ and the DCS systems has been built and tested over the last three years at Fermilab’s Feynman Computing Center, and now the production system installation is underway. This work presents their status and focus on the installation plans and procedures for racks, workstations, network switches, gateway computers, DAQ hardware, slow controls implementation, and testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗