Engineering Papers⌕ Search

DOE OSTI · 1706618

The GlueX beamline and detector

Abstract

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adhikari, S., Akondi, C. S., Al Ghoul, H., Ali, A., Amaryan, M., Anassontzis, E. G., Austregesilo, A., Barbosa, F., Barlow, J., Barnes, A., Barriga, E., Barsotti, R., Beattie, T. D., Benesch, J., Berdnikov, V. V., Biallas, G., Black, T., Boeglin, W., Brindza, P., Briscoe, W. J., Britton, T., Brock, J., Brooks, W. K., Cannon, B. E., Carlin, C., Carman, D. S., Carstens, T., Cao, N., Chernyshov, O., Chudakov, E., Cole, S., Cortes, O., Crahen, W. D., Crede, V., Dalton, M. M., Daniels, T., Deur, A., Dickover, C., Dobbs, S., Dolgolenko, A., Dotel, R., Dugger, M., Dzhygadlo, R., Dzierba, A., Egiyan, H., Erbora, T., Ernst, A., Eugenio, P., Fanelli, C., Fegan, S., Foda, A. M., Foote, J., Frye, J., Furletov, S., Gan, L., Gasparian, A., Gerasimov, A., Gevorgyan, N., Gleason, C., Goetzen, K., Goncalves, A., Goryachev, V. S., Guo, L., Hakobyan, H., Hamdi, A., Hardin, J., Henschel, C. L., Huber, G. M., Hutton, C., Hurley, A., Ioannou, P., Ireland, D. G., Ito, M. M., Jarvis, N. S., Jones, R. T., Kakoyan, V., Katsaganis, S., Kalicy, G., Kamel, M., Keith, C. D., Klein, F. J., Kliemt, R., Kolybaba, D., Kourkoumelis, C., Krueger, S. T., Kuleshov, S., Larin, I., Lawrence, D., Leckey, J. P., Lersch, D. I., Leverington, B. D., Levine, W. I., Li, W., Liu, B., Livingston, K., Lolos, G. J., Lyubovitskij, V., Mack, D., Marukyan, H., Mattione, P. T.. 2020-10-21. The GlueX beamline and detector. https://doi.org/10.1016/j.nima.2020.164807

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗