Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solar interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Did Geomagnetic Activity Challenge Electric Power Reliability During Solar Cycle 23? Evidence from the PJM Regional Transmission Organization in North America

During solar cycle 22, a very intense geomagnetic storm on 13 March 1989 contributed to the collapse of the Hydro-Quebec power system in Canada. This event clearly demonstrated that geomagnetic storms have the potential to lead to blackouts. This paper addresses whether geomagnetic activity challenged power system reliability during solar cycle 23. Operations by PJM Interconnection, LLC (hereafter PJM), a regional transmission organization in North America, are examined over the period 1 April 2002 through 30 April 2004. During this time PJM coordinated the movement of wholesale electricity in all or parts of Delaware, Maryland, New Jersey, Ohio, Pennsylvania, Virginia, West Virginia, and the District of Columbia in the United States. We examine the relationship between a proxy of geomagnetically induced currents (GICs) and a metric of challenged reliability. In this study, GICs are proxied using magnetometer data from a geomagnetic observatory located just outside the PJM control area. The metric of challenged reliability is the incidence of out-of-economic-merit order dispatching due to adverse reactive power conditions. The statistical methods employed make it possible to disentangle the effects of GICs on power system operations from purely terrestrial factors. The results of the analysis indicate that geomagnetic activity can significantly increase the likelihood that the system operator will dispatch generating units based on system stability considerations rather than economic merit.

storms↗

Evaluation of glass resin coatings for solar cell applications

Using a variety of non-vacuum deposition techniques coatings were implemented on silicon solar cells and arrays of cells interconnected on Kapton substrates. The coatings provide both antireflection optical matching and environmental protection. Reflectance minima near 2% was achieved at a single wavelength in the visible. Reflectance averaging below 5% across the useful collection range was demonstrated. The coatings and methods of deposition were: (1) Ta2O5 spun, dipped or sprayed; (2) Ta2O5.SiO2 spun, dipped or sprayed; (3) GR908 (SiO2) spun, dipped, or sprayed. Total coating thickness were in the range of 18 microns to 25 microns. The coatings and processes are compatible with single cells or cells mounted on Kapton substrates.

Field, M. B.↗

A transient plasticity study and low cycle fatigue analysis of the Space Station Freedom photovoltaic solar array blanket

The Space Station Freedom photovoltaic solar array blanket assembly is comprised of several layers of materials having dissimilar elastic, thermal, and mechanical properties. The operating temperature of the solar array, which ranges from -75 to +60 C, along with the material incompatibility of the blanket assembly components combine to cause an elastic-plastic stress in the weld points of the assembly. The weld points are secondary structures in nature, merely serving as electrical junctions for gathering the current. The thermal mechanical loading of the blanket assembly operating in low earth orbit continually changes throughout each 90 min orbit, which raises the possibility of fatigue induced failure. A series of structural analyses were performed in an attempt to predict the fatigue life of the solar cell in the Space Station Freedom photovoltaic array blanket. A nonlinear elastic-plastic MSC/NASTRAN analysis followed by a fatigue calculation indicated a fatigue life of 92,000 to 160,000 cycles for the solar cell weld tabs. Additional analyses predict a permanent buckling phenomenon in the copper interconnect after the first loading cycle. This should reduce or eliminate the pulling of the copper interconnect on the joint where it is welded to the silicon solar cell. It is concluded that the actual fatigue life of the solar array blanket assembly should be significantly higher than the calculated 92,000 cycles, and thus the program requirement of 87,500 cycles (orbits) will be met. Another important conclusion that can be drawn from the overall analysis is that, the strain results obtained from the MSC/NASTRAN nonlinear module are accurate to use for low-cycle fatigue analysis, since both thermal cycle testing of solar cells and analysis have shown higher fatigue life than the minimum program requirement of 87,500 cycles.

Armand, Sasan C.↗

Solar array arcing in plasmas

Solar cells in space plasma conditions are known to arc into the plasma when the interconnects are at a negative potential of a few hundred volts, relative to plasma potential. For cells with silver-coated interconnects, a threshold voltage for arcing exists at about -230 V, as found in both ground and LEO experiments. The arc rate beyond the threshold voltage depends nearly linearly on plasma density, but has a strong power-law dependence on voltage, such that for small increments in operating voltage there is a large increment in arc rate. The arcs generate broadband radio interference and visible light. In ground tests, interconnects have been damaged by arcs in cells having insufficient isolation from a source of high current. Models for the arcs are highly dependent on the choice of interconnect conductor material exposed to the plasma and possibly on the geometry and choice of adjacent insulator material. Finally, new technology solar cells use copper for the cell interconnects, a material which may have a lower arcing threshold voltage than silver. It is expected, from ground tests of simulated solar cells, that any junction of conductor and insulator exposed to space plasma conditions will arc into the plasma at a few hundred volts negative potential, relative to the local plasma.

Ferguson, Dale C.↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Loss of Glen Canyon Dam Hydropower Plant Capabilities

The power grid in the western United States is undergoing a major transformation, driven by technological advancements, power markets, policy shifts, and evolving energy demands. The integration of variable renewable energy (VRE) resources, such as wind and solar, into the power grid has become a major driver of change. Between 2018 and 2023, about 19 gigawatts (GW) of new solar capacity and 14 GW of new wind capacity was built in the Western Interconnection (WI) region. These two VRE resources accounted for the majority of WI capacity additions. The Western Interconnection is expected to host 30 GW of wind, 40 GW of solar, and 14 GW of energy storage by 2030 (Western Electricity Coordinating Council n.d.).

13 HYDRO ENERGY↗

Thermophotovoltaic Cell Technology Transferred to the Department of Energy Laboratory and a Commercial Manufacturer

Researchers in the NASA Lewis Research Center's Photovoltaic Branch have developed novel photovoltaic device, called a Monolithically Interconnected Module (MIM), for use in thermophotovoltaic (TPV) power systems. TPV power systems function by heating an emitter to produce light. This light is then converted into electricity by a photovoltaic device or a solar cell. Possible heat sources for the system include concentrated solar energy, the combustion of various fuels, and nuclear decay. NASA has an interest in TPV systems for deep space (nuclear-powered) and near-Sun (solar-powered) missions. There also are many commercial and military applications for TPV, given its potential for high efficiency, low noise, and reliable power. The Monolithically Interconnected Module consists of many small solar cells that are series-interconnected on a common substrate. The cells are fabricated from indium gallium arsenide (InGaAs), which can convert the near-infrared portion of the emitter output spectrum into electricity. The InGaAs devices are deposited on an indium phosphide (InP) substrate that provides electrical isolation. On the bottom the InP substrate is an infrared reflector that returns all the photons that are not converted by the InGaAs device back to the emitter where they are absorbed. This process helps maintain the emitter temperature and dramatically improves the system efficiency. Monolithically Interconnected Module InGaAs thermophotovoltaic cell developed by Lewis. Compared with conventional TPV cells, this TPV device has higher output voltages and lower resistive losses, higher output power density, simplified thermal management, improved reliability, and higher efficiency. The Monolithically Interconnected Module was initially developed under an internally funded effort (Director's Discretionary Fund). Development is now being funded by another government agency, and prototype devices are being produced by a commercial solar cell manufacturer.

Wilt, David M.↗

Evolution of integrated panel structural design and interfaces for PV power plants

The evolution of integrated photovoltaic (PV) panel design at ARCO Solar is discussed. Historically, framed PV modules of about 1 x 4-ft size were individually mounted in the field on fixed support structures and interconnected electrically with cables to build higher-power arrays. When ARCO Solar saw the opportunity in 1982 to marry its PV modules with state-of-the-art heliostat trackers developed by ARCO Power Systems, it became obvious that mounting individual modules was impractical. For this project, the framed modules were factory-assembled into panels and interconnected with cables before being mounted on the trackers. Since then, ARCO Solar made considerable progress and gained substantial experience in the design and fabrication of large PV panels. Constraints and criteria considered in these design activities included static and dynamic loads; assembly and transportation equipment and logistics, structural and electrical interfaces, and safety and grounding concerns.

Arnett, J. C.↗

34% Efficient InGaP/GaAs/GaSb Cell-Interconnected-Circuits for Line-Focus Concentrator Arrays

While monolithic multi-junction cells are preferred for flat plate arrays, mechanically stacked multi-junction cells are superior for solar concentrator applications. Reasons for this are that the mechanical stacked configuration with high efficiency Gallium Antimonide cells allows utilization of a much wider range of the solar energy spectrum, and the ability to use voltage matched interconnects results in full use of low bandgap cell currents. Herein, data are presented for simple two terminal voltage-matched circuits using InGaP/GaAs/GaSb stacked cells showing 34% average circuit efficiency for a lot of 12 circuits given prismatic covers. These circuits have been designed to fit into the ultralight Stretched Lens Array being developed by NASA. With these new cell-interconnected-circuits, we project that the power density at GEO operating temperature can be increased from 296 W/m2 to 350 W/m2 while maintaining the specific power at 190 W/kg at the full wing level.

Fraas, L. M.↗

The driving force for magnetospheric convection

Viscously driven magnetospheric models, as well as a model involving interconnection between the geomagnetic field and the magnetic field in the solar wind, have been proposed to describe the driving force for magnetospheric convection. Lack of a satisfactory theory for the interconnection in the latter model and, in the case of the viscous interaction models, inadequacies in predicting the quantity of the driving force, make these two classes of models less than successful. Accordingly, a mechanically driven magnetospheric model is proposed: solar wind plasma enters the magnetosphere around the neutral points, covers the inner surface of the magnetopause and subsequently expands, driving convection as it escapes from the open tail.

Johnson, F. S.↗

Mix and match light absorbers

Here, perovskite and organic semiconductors can be combined to make tandem solar cells but, to date, their efficiency has hovered around 20%. Now, researchers demonstrate a 23.6% tandem by reducing interfacial defects to improve the perovskite cell's voltage and developing an ultrathin interconnection layer.

14 SOLAR ENERGY↗

One Year In: Tracking the Impacts of NEM 3.0 on California’s Residential Solar Market

On December 15, 2022, the California Public Utilities Commission passed an overhaul of the net metering program for the state’s investor-owned utilities. The changes replaced the long-standing net energy metering (NEM) tariffs with a net billing tariff (NBT) structure—colloquially known as “NEM 3.0”—which significantly reduces the compensation for behind-the-meter solar photovoltaic (PV) systems. The NEM tariffs remained open for new interconnection applications until April 15, 2023, but after that date, all new interconnection applications were submitted under NBT. Now, one year later, we have an opportunity to evaluate how the California solar market has evolved under this new compensation regime. As a precursor to its annual Tracking the Sun report, Berkeley Lab has released a short technical brief describing key trends in the California residential solar market since the roll-out of the new NBT structure. The purpose of this analysis is to provide empirical insights into how the market has evolved over the past year, confirming some expectations while also revealing several striking surprises.

14 SOLAR ENERGY↗

Cybersecurity Considerations for Grid-Connected Batteries with Hardware Demonstrations

The share of renewable and distributed energy resources (DERs), like wind turbines, solar photovoltaics and grid-connected batteries, interconnected to the electric grid is rapidly increasing due to reduced costs, rising efficiency, and regulatory requirements aimed at incentivizing a lower-carbon electricity system. These distributed energy resources differ from traditional generation in many ways including the use of many smaller devices connected primarily (but not exclusively) to the distribution network, rather than few larger devices connected to the transmission network. DERs being installed today often include modern communication hardware like cellular modems and WiFi connectivity and, in addition, the inverters used to connect these resources to the grid are gaining increasingly complex capabilities, like providing voltage and frequency support or supporting microgrids. To perform these new functions safely, communications to the device and more complex controls are required. The distributed nature of DER devices combined with their network connectivity and complex controls interfaces present a larger potential attack surface for adversaries looking to create instability in power systems. To address this area of concern, the steps of a cyberattack on DERs have been studied, including the security of industrial protocols, the misuse of the DER interface, and the physical impacts. These different steps have not previously been tied together in practice and not specifically studied for grid-connected storage devices. In this work, we focus on grid-connected batteries. We explore the potential impacts of a cyberattack on a battery to power system stability, to the battery hardware, and on economics for various stakeholders. We then use real hardware to demonstrate end-to-end attack paths exist when security features are disabled or misconfigured. Our experimental focus is on control interface security and protocol security, with the initial assumption that an adversary has gained access to the network to which the device is connected. We provide real examples of the effectiveness of certain defenses. This work can be used to help utilities and other grid-connected battery owners and operators evaluate the severity of different threats and the effectiveness of defense strategies so they can effectively deploy and protect grid-connected storage devices.

25 ENERGY STORAGE↗

Metalization Patterns by Thermal Decomposition

Metal interconnection pattern deposited on integrated circuit or solar cell economically by thermal decomposition of metallo-organic compound. In proposed process beam from laser or quartz lamp swept over substrate in required metalization pattern; wherever beam impinges on substrate, radiant heat decomposes compound, depositing metal. Process requires less costly equipment and less time than conventional metalization. Process readily adaptable to very-large-scale integrated (VLSI) circuits.

Gallagher, B. D.↗