Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting Cement-Sheath Integrity with Consideration of Initial State of Stress and Thermoporoelastic Effects

In conventional wellbore-integrity analysis, the cement sheath’s initial state of stress and transient thermoporoelastic effects are often neglected. However, the initial state of stress is prerequisite information for accurately predicting the safe operating conditions that prevent a cemented well from being damaged. In addition, transient thermoporoelastic effects can have a profound effect on when damage will occur. Here in this paper, we propose a model that includes these effects to predict the safe operating pressures and temperatures that will prevent cement-sheath failure. For the initial state of stress, we proposed an empirical model using measurements. Subsequent stress changes are evaluated by a fully coupled transient thermoporoelastic model to analyze the mechanical behavior of the cement sheath. We predict the safe operating envelope (SOE) for shear, tensile, and debonding cement-sheath failures caused by pressure and temperature perturbations after the cement sets. Our model predicts that pore pressure is a key factor for cement failure, especially for rapid temperature changes. If the formation is low permeability, the transient pore pressures are amplified, causing the risk of damage to increase. Compared with conventional thermoelastic models, the thermoporoelastic model predicts a smaller SOE when heating the internal casing fluid and a larger envelope when cooling the internal casing fluid. Finally, the heating rate was considered with respect to field applications. The heating rate was also considered, and slower heating/cooling rates can prevent damage to the cement sheath. Finally, the thermoporoelastic model was applied to explain several laboratory and field experiments and achieved good matches.

02 PETROLEUM↗

A Survey on the Expanding Scope and Interdisciplinary Opportunities for Processing-in-Memory Techniques

Processing-in-Memory (PIM) is emerging as a practical path to overcome the limitations of traditional von Neumann architectures. At its core, PIM systems implement computing primitives such as logic operations and multiply-accumulate acceleration through compute-in-memory, near-memory processing, or hybrid designs. The role of memory cells varies widely across technologies, acting as inputs, outputs, or analog accumulators through bit-lines and sense amplifiers. This diversity creates trade-offs in precision, bandwidth, latency, and programmability, making it difficult to build a unified understanding on the progress of the field. In this survey, we organize recent advances of PIM into three areas. First, we discuss the progress on the architectural optimizations of PIM and its integration with both DRAM and emerging non-volatile memories. Second, we examine how PIM is being used to accelerate key computing domains, including generative AI workloads and high-performance kernels, along with new approaches. Third, we highlight the growing adoption of PIM in computational sciences, where it is being applied to solve interdisciplinary problems such as genome analysis, mRNA quantification, mass spectrometry, quantum circuit simulation, wave modeling, and secure computation. Finally, we synthesize the major challenges that continue to slow PIM adoption, including manufacturing constraints, power delivery, thermal reliability, data consistency, runtime and memory-management coordination, and the difficulty of building portable software abstractions without sacrificing commercial viability. This work provides an updated, structured perspective on PIM’s potential across computing and computational sciences and the barriers that must be solved for it to reach its full impact.

Asifuzzaman, Kazi [Oak Ridge National Laboratory (↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

The Impact of Catalyst Layer Properties and Transport Layer Interactions on Rutile Iridium Oxide Anode Durability in Proton Exchange Membrane Electrolysis

The performance and durability of proton exchange membrane electrolyzers are governed by the interplay between catalyst inks and integration, the resulting catalyst layer (CL) structure, and the interface between the CL and porous transport layer (PTL). In this study, we examine the impact of these factors on cell performance and degradation using rutile IrO2 as the anode catalyst. The two commercial rutile IrO2 catalysts differ from each other and from the amorphous benchmark in agglomerate size and ink stability. This has implications for CL morphology and electronic connectivity. In the context of long-term pressurized operation for up to 1000 h, the selection of the PTL has a marginal effect on the durability of CLs with good structural and compositional properties, whereas poorly structured CLs demonstrate evident degradation when used with certain PTLs. Poor CL properties amplify the negative impact of non-ideal CL/PTL interfaces, demonstrating the importance of CL/PTL interface engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coherent Combining for High‐Power Kerr Combs

Abstract Kerr frequency combs enable the miniaturization of comb sources for applications such as data communications and spectroscopy. However, due to the high field confinement and effective nonlinearity, Kerr combs typically operate with low output comb powers. While nonsolitonic Kerr combs operating in the normal group velocity dispersion (GVD) regime can access high pump‐to‐comb conversion efficiencies and relatively flat spectral profiles, many frequency comb applications require even higher comb‐line powers that are otherwise fundamentally unattainable without the use of optical amplifiers. A high efficient coherent beam combining of Kerr combs is demonstrated via on‐chip synchronization to greatly enhanced comb‐line powers. Two normal GVD Kerr combs are coherently combined for a 2.9 dB increase in comb power compared to a single comb while maintaining a high total pump‐to‐comb conversion efficiency of 26%. Lastly, it is shown that via spectral engineering of two normal GVD combs, it should be possible to significantly increase the spectral flatness of a combined comb. This platform enables fully integrated systems with powers that can readily exceed that of an individual comb system by more than an order of magnitude.

Kim, Bok Young↗

LGAD-in-CMOS Design Studies

We describe a process flow for a CMOS sensor with intrinsic gain. The design is based on a base wafer which is prepared with closely spaced buried n and p doping layers that form an amplifying high field gain region when the device is biased. A deep n-well forms the collecting electrode. The buried n layer serves to moderate the internal field so that the CMOS transistors within the n-well remain within their operating region.

43 PARTICLE ACCELERATORS↗

Selective Enhancement of Spectroscopic Features by Quantum Optimal Control

Tailored light can be used to steer atomic motions into selected quantum pathways. In optimal control theory (OCT), the target is usually expressed in terms of the molecular wave function, a quantity that is not directly observable in experiment. In this study, we present simulations using OCT that optimize the spectroscopic signal itself. By shaping the optical pump, the x-ray stimulated Raman signal, which occurs solely during the passage through conical intersections, is temporally controlled and amplified by up to 2 orders of magnitude. This enhancement can be crucial in order to bring small coherence-based signatures above the detectable threshold. Our approach is applicable to any signal that depends on the expectation value of a positive definite operator.

74 ATOMIC AND MOLECULAR PHYSICS↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Sub-single exciton optical gain threshold in colloidal semiconductor quantum wells with gradient alloy shelling

Colloidal semiconductor quantum wells have emerged as a promising material platform for use in solution-processable lasers. However, applications relying on their optical gain suffer from nonradiative Auger decay due to multi-excitonic nature of light amplification in II-VI semiconductor nanocrystals. Here, we show sub-single exciton level of optical gain threshold in specially engineered CdSe/CdS@CdZnS core/crown@gradient-alloyed shell quantum wells. This sub-single exciton ensemble-averaged gain threshold of (Ng)≈ 0.84 (per particle) resulting from impeded Auger recombination, along with a large absorption cross-section of quantum wells, enables us to observe the amplified spontaneous emission starting at an ultralow pump fluence of ~ 800 nJ cm –2 , at least three-folds better than previously reported values among all colloidal nanocrystals. Finally, using these gradient shelled quantum wells, we demonstrate a vertical cavity surface-emitting laser operating at a low lasing threshold of 7.5 μJ cm –2 . These results represent a significant step towards the realization of solution-processable electrically-driven colloidal lasers.

36 MATERIALS SCIENCE↗

Nonlinear regenerative amplification using tunable intracavity cascaded quadratic nonlinearities

Conventional nonlinear regenerative amplification utilizes Kerr (i.e., self-focusing) nonlinearity to broaden the spectrum via self-phase modulation during the direct amplification of ultrashort pulses, which helps overcome spectral gain narrowing for high-energy, ultrashort-pulse generation. We introduce cascaded quadratic nonlinearities from a type-I second-harmonic generation crystal, which can be tuned in both magnitude and sign via the phase-mismatching condition, inside a regenerative amplifier to enable nonlinearity-tunable regenerative amplification. We demonstrate, both experimentally and numerically, a nonlinear Yb:YAG thin-disk regenerative amplifier with either positive or negative net nonlinearity that delivers 1-kHz, >0.4-mJ pulses as short as ∼200 fs and high-quality beams free of self-focusing. The laser’s average power can be scaled to >100 W when seeded and operated at a much higher repetition rate to benefit various applications.

47 OTHER INSTRUMENTATION↗

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front- end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high-speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel. Another novel low-power circuit called Pseudo-Thyristor presented in another document will replace traditional discriminator and the Regenerative Current Mirror plus Pseudo- Thyristor will provide a full solution for the silicon pixel low-power frontend ASIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Throughput Genome Releaser

In this study, we present the development of a High Throughput Genome Releaser, an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed for rapid, cost-effective, and efficient DNA extraction, optimized for subsequent PCR reactions. Our experimentation with various synthetic materials led us to select a particular type of plastic that mirrors the properties of glass cover slides, providing a smooth surface and effective compression capabilities. We engineered a 96-well device equipped with a 96-well plate and a top rod, operable both manually and automatically, which is compatible with widely used liquid-handling robot decks. This compatibility enhances ease of use in high-throughput PCR setups. Additionally, we developed software to support its automatic functions. The genome releaser facilitates the extraction of PCR-amplifiable genomic DNA from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells. This versatility could significantly advance biomanufacturing processes.

42 ENGINEERING↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Removing numerical pathologies in a turbulence parameterization through convergence testing

Discretized numerical models of the atmosphere are usually intended to faithfully represent an underlying set of continuous equations, but this necessary condition is violated sometimes by subtle pathologies that have crept into the discretized equations. Such pathologies can introduce undesirable artifacts, such as sawtooth noise, into the model solutions. The presence of these pathologies can be detected by numerical convergence testing. This study employs convergence testing to verify the discretization of the Cloud Layers Unified By Binormals (CLUBB) model of clouds and turbulence. That convergence testing identifies two aspects of CLUBB's equation set that contribute to undesirable noise in the solutions. First, numerical limiters (i.e. clipping) used by CLUBB introduce discontinuities or slope discontinuities in model fields. Second, this noise can be amplified by an advective term in CLUBB's background diffusion. Smoothing the limiters and removing the advective component of the background diffusion reduces the noise and restores the expected first-order convergence in CLUBB's solutions. These model reformulations improve the results at coarser, near-operational grid spacing and time step in cumulus cloud and dry turbulence tests. In addition, convergence testing is proved to be a valuable tool for detecting pathologies, including unintended discontinuities and grid dependence, in the model equation set.

Mathematics and Computing, Geosciences↗

Two and three-dimensional near infrared subcutaneous structure imager using realtime nonlinear video processing

A method includes placing an imaging device in contact with a sample, irradiating the sample via an illuminator such that radiation scatters off of the structure, and providing the scattered radiation to a detector to generate a digital video signal. A processor then performs various operations including subtracting a sum of a black state value and a user-defined black level clamping value from the digital video signal to create subtracted image data, substituting negative values in the subtracted image data with a reference value to create modified image data, and amplifying the modified image data by a user-defined gain to create contrast enhanced image data.

Krasowski, Michael J.↗