Particle Size Analysis and Distribution

Abstract

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joe, Donavon, Ajo, Henry, O'Rourke, Patrick E., Housley, Catherine E., Missimer, David M., Maldonado-Figueroa, Cristian. 2019-07-01. Particle Size Analysis and Distribution. https://www.osti.gov/biblio/23005519

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗