NASA NTRS · 19760059093
Diffraction effects on angular response of X-ray collimators
Abstract
Angular responses have been measured for X-ray collimators with half-widths ranging from minutes of arc down to 10 arcsec. In the seconds-of-arc range, diffraction peaks at off-axis angles can masquerade as side lobes of the collimator angular response. Measurements and qualitative physical arguments lead to a rule of thumb for collimator design; namely, the angle of first minimum in the Fraunhofer single-slit diffraction pattern should be less than one-fourth of the collimator geometrical full-width at half-maximum intensity.
Keep this discovery
Explore connections, maps & timelines
Blake, R. L., Barrus, D. M., Fenimore, E.. 1976-08-01. Diffraction effects on angular response of X-ray collimators. https://ntrs.nasa.gov/citations/19760059093
Cite the original work for its findings. Save a collection to share your selection of sources.