Engineering Papers⌕ Search

Engineering topics

Huang, Z

Publications and source records attributed to Huang, Z.

At least 55 records · Page 3

Covalent Incorporation of Selenium into Oligonucleotides for X-ray Crystal Structure Determination via MAD: Proof of Principle

Selenium was incorporated into an oligodeoxynucleotide in the form of 2'-methylseleno-uridine (U{sub Se}). The X-ray crystal structure of the duplex d(GCGTA)U{sub Se}d(ACGC){sub 2} was determined by the multiwavelength anomalous dispersion (MAD) technique and refined to a resolution of 1.3 {angstrom}, demonstrating that selenium can selectively substitute oxygen in DNA and that the resulting compounds are chemically stable. Since derivatization at the 2'-{alpha}-position with selenium does not affect the preference of the sugar for the C3'-endo conformation, this strategy is suitable for incorporating selenium into RNA. The availability of selenium-containing nucleic acids for crystallographic phasing offers an attractive alternative to the commonly used halogenated pyrimidines.

36 MATERIALS SCIENCE↗

Synthesis and Crystal Structure Study of 2’-Se-Adenosine-Derivatized DNA

The selenium derivatization of nucleic acids is a novel and promising strategy for 3D structure determination of nucleic acids. Selenium can serve as an excellent anomalous scattering center to solve the phase problem, which is one of the two major bottlenecks in macromolecule X-ray crystallography. The other major bottleneck is crystallization. It has been demonstrated that the incorporated selenium functionality at the 2'-positions of the nucleosides and nucleotides is stable and does not cause significant structure perturbation. Furthermore, it was observed that the 2'-Se-derivatization could facilitate crystallization of oligonucleotides with fast crystal growth and high diffraction quality. Herein, we describe a convenient synthesis of the 2'-Se-adenosine phosphoramidite, and report the first synthesis and X-ray crystal structure determination of the DNA containing the 2'-Se-A derivatization. The 3D structure of 2'-Se-A-DNA decamer [5'-GTACGCGT(2'-Se-A)C-3']{sub 2} was determined at 1.75 {angstrom} resolution, the 2'-Se-functionality points to the minor groove, and the Se-modified and native structures are virtually identical. Moreover, we have observed that the 2'-Se-A modification can greatly facilitate the crystal growth with high diffraction quality. In conjunction with the crystallization facilitation by the 2'-Se-U and 2'-Se-T, this novel observation on the 2'-Se-A functionality suggests that the 2'-Se moiety is sole responsible for the crystallization facilitation and the identity of nucleobases does not influence the crystal growth significantly.

59 BASIC BIOLOGICAL SCIENCES↗

High Fidelity of Base Paring by 2-Selenothymidine in DNA

The base pairs are the contributors to the sequence-dependent recognition of nucleic acids, genetic information storage, and high fidelity of DNA polymerase replication. However, the wobble base pairing, where T pairs with G instead of A, reduces specific base-pairing recognition and compromises the high fidelity of the enzymatic polymerization. Via the selenium atomic probing at the 2-position of thymidine, we have investigated the wobble discrimination by manipulating the steric and electronic effects at the 2-exo position, providing a unique chemical strategy to enhance the base pair specificity. We report here the first synthesis of the novel 2-Se-thymidine ({sup Se}T) derivative, its phosphoramidite, and the Se-DNAs. Our biophysical and structural studies of the 2-Se-T DNAs reveal that the bulky 2-Se atom with a weak hydrogen-bonding ability can largely increase mismatch discriminations (including T/G wobble and T/C mismatched base pairs) while maintaining the {sup Se}T/A virtually identical to the native T/A base pair. The 2-Se atom bulkiness and the electronic effect are probably the main factors responsible for the discrimination against the formation of the wobble {sup Se}T/G base pair. Our investigations provide a potential novel tool to investigate the specific recognition of base pairs, which is the basis of high fidelity during replication, transcription, and translation. Furthermore, this Se-atom-specific substitution and probing are useful for X-ray crystal structure and function studies of nucleic acids.

59 BASIC BIOLOGICAL SCIENCES↗

Synthesis and Crystal Structure of 2’-Se-modified guanosine Containing DNA

Selenium modification of nucleic acids is of great importance in X-ray crystal structure determination and functional study of nucleic acids. Herein, we describe a convenient synthesis of a new building block, the 2{prime}-SeMe-modified guanosine (G{sub Se}) phosphoramidite, and report the first incorporation of the 2{prime}-Se-G moiety into DNA. The X-ray crystal structure of the 2{prime}-Se-modified octamer DNA (5{prime}-GTG{sub Se}TACAC-3{prime}) was determined at a resolution of 1.20 {angstrom}. We also found that the 2{prime}-Se modification points to the minor groove and that the modified and native structures are virtually identical. Furthermore, we observed that the 2{prime}-Se-G modification can significantly facilitate the crystal growth with respect to the corresponding native DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Feasibility Study for a Seeded Hard X-ray Source Based on a Two-Stage Echo-Enabled Harmonic Generation FEL

We propose and analyze a scheme to achieve a seeded hard x-ray source based on a two-stage echo-enabled harmonic generation (EEHG) FEL. In the scheme an 180 nm seed laser covering the whole bunch is first used to modulate the beam when beam energy is 2 GeV. After passing through a strong chicane complicated fine structures are introduced into the phase space. The beam is again modulated by a short 180 nm laser that only interacts with the rear part of the beam and accelerated to 6 GeV. A chicane is then used to convert the energy modulation imparted to the rear part of the beam into density modulation. The density-modulated beam is sent through a radiator to generate intense 6 nm radiation which will be used to interact with the front fresh part of the bunch. Finally we generate in the front part of the beam density modulation at the 1199th harmonic of the seed laser. We will discuss the issues related to the realization of the seeded hard x-ray FEL.

43 PARTICLE ACCELERATORS↗

Generation of Attosecond X-ray Pulses Beyond the Atomic Unit of Time Using Laser Induced Microbunching in Electron Beams

Ever since the discovery of mode-locking, efforts have been devoted to reducing the duration of laser pulses since the ultrashort pulses are critical to explore the dynamics occurred on a ever-shorter timescale. In this paper we describe a scheme that's capable of generating intense attosecond x-ray pulses with duration beyond the atomic unit of time ({approx}24 attoseconds). The scheme combines the echo-enabled harmonic generation technique with the bunch compression which allows one to generate harmonic numbers of a few hundred in a microbunched beam through up-conversion of the frequency of a UV seed laser. A few-cycle intense IR laser is used to generate the required energy chirp in the beam for bunch compression and for selection of an attosecond x-ray pulse. Using a representative realistic set of parameters, we show that 1 nm x-ray pulse with peak power of a few hundred MW and duration as short as 20 attoseconds (FWHM) can be generated from a 200 nm UV seed laser. The proposed scheme may enable the study of electronic dynamics with a resolution beyond the atomic unit of time and may open a new regime of ultrafast sciences.

43 PARTICLE ACCELERATORS↗

FEL and Optical Klystron Gain for an Electron Beam with Oscillatory Energy Distribution

If the energy spread of a beam is larger then the Pierce parameter, the FEL gain length increases dramatically and the FEL output gets suppressed. We show that if the energy distribution of such a beam is made oscillatory on a small scale, the gain length can be considerably decreased. Such an oscillatory energy distribution is generated by first modulating the beam energy with a laser via the mechanism of inverse FEL, and then sending it through a strong chicane. We show that this approach also works for the optical klystron enhancement scheme. Our analytical results are corroborated by numerical simulations.

43 PARTICLE ACCELERATORS↗

FEL GAIN LENGTH AND TAPER MEASUREMENTS AT LCLS

We present experimental studies of the gain length and saturation power level from 1.5 nm to 1.5 Angstroms at the Linac Coherent Light Source (LCLS). By disrupting theFEL process with an orbit kick, we are able to measure the X-ray intensity as a function of undulator length. This kick method is cross-checked with the method of removing undulator sections. We also study the FEL-induced electron energy loss after saturation to determine the optimal taper of the undulator K values. The experimental results are compared to theory and simulations.

43 PARTICLE ACCELERATORS↗

Measurements and Simulations of Ultralow Emittance and Ultrashort Electron Beams in the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser project presently in a commissioning phase at the SLAC National Accelerator Laboratory. We report here on very low-emittance measurements made at low bunch charge, and a few femtosecond bunch length produced by the LCLS bunch compressors. Start-to-end simulations associated with these beam parameters show the possibilities of generating hundreds of GW at 1.5 A ring x-ray wavelength and nearly a single longitudinally coherent spike at 1.5 nm with 2-fs duration.

43 PARTICLE ACCELERATORS↗

Polarization Analysis of Nonlinear Harmonic Radiation in a Crossed-Planar Undulator

There is growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. The crossed-planar undulator, which was first proposed by Kim, could achieve rapid polarization control in synchrotron radiation sources and free electron lasers (FELs) through the manipulation of a phase shifter. Recently, a statistical analysis shows that a polarization degree of over 80% is obtainable for a Self-Amplified Spontaneous Emission (SASE) FEL near saturation. In such a scheme, nonlinear harmonic radiation is also generated in each undulator and the polarization of the radiation is controllable in the same manner. In this paper, we study the degree of polarization achievable at the third harmonic in a crossed-planar undulator. We also propose a method for generating second harmonic radiation with arbitrary polarization.

43 PARTICLE ACCELERATORS↗

Start-to-End Simulations of the LCLS Accelerator and FEL Performance at Very Low Charge

The Linac Coherent Light Source (LCLS) is an x-ray Free-electron Laser (FEL) being commissioned at Stanford Linear Accelerator Center (SLAC). Recent beam measurements have shown that, using the LCLS injector-linac-compressors, the beam emittance is very small at 20 pC. In this paper we perform start-to-end simulations of the entire accelerator including the FEL undulator and study the FEL performance versus the bunch charge. At 20 pC charge, these calculations associated with the measured beam parameters suggest the possibility of generating a longitudinally coherent single x-ray spike with 2-femtosecond (fs) duration at a wavelength of 1.5 nm. At 100 pC charge level, our simulations show an x-ray pulse with 10 femtosecond duration and up to 10{sup 12} photons at a wavelength of 1.5 {angstrom}. These results open exciting possibilities for ultrafast science and single shot molecular imaging.

43 PARTICLE ACCELERATORS↗

Optics Design for a Soft X-ray FEL at the SLAC A-Line

LCLS capabilities can be significantly extended with a second undulator aiming at the soft x-ray spectrum (1-5 nm). To allow for simultaneous hard and soft x-ray operations, 14 GeV beams at the end of the LCLS accelerator can be intermittently switched into the SLAC A-line (the beam transport line to End Station A) where the second undulator may be located. In this paper, we discuss the A-line optics design for transporting the high-brightness LCLS beams using the existing tunnel. To preserve the high brightness of the LCLS beams, special attention is paid to effects of incoherent and coherent synchrotron radiation. Start-to-end simulations using realistic LCLS beam distributions are carried out.

43 PARTICLE ACCELERATORS↗

Generating Intense Attosecond X-Ray Pulses Using Ultraviolet-Laser-Induced Microbunching in Electron Beams

We propose a scheme that combines the echo-enabled harmonic generation technique with the bunch compression and allows to generate harmonic numbers of a few hundred in a microbunched beam through up-conversion of the frequency of an ultraviolet seed laser. Sending this beam through a short undulator results in an isolated sub-100 attoseconds pulse of x-ray radiation. Using a representative realistic set of parameters, we show that 1 nm x-ray pulse with peak power exceeding 100 MW and duration as short as 34 attoseconds (FWHM) can be generated from a 200 nm ultraviolet seed laser.

43 PARTICLE ACCELERATORS↗

Generation of attosecond x-ray pulses with a multi-cycle two-color ESASE scheme

Generation of attosecond x-ray pulses is attracting much attention within the x-ray free-electron laser (FEL) user community. Several schemes using extremely short laser pulses to manipulate the electron bunches have been proposed. In this paper, we extend the attosecond two-color ESASE scheme proposed by Zholents et al. to the long optical cycle regime using a second detuned laser and a tapered undulator. Both lasers can be about ten-optical-cycles long, with the second laser frequency detuned from the first to optimize the contrast between the central and side current spikes. A tapered undulator mitigates the degradation effect of the longitudinal space charge (LSC) force in the undulator and suppresses the FEL gain of all side current peaks. Simulations using the LCLS parameters show a single attosecond x-ray spike of {approx} 110 attoseconds can be produced. The second laser can also be detuned to coherently control the number of the side x-ray spikes and the length of the radiation pulse.

43 PARTICLE ACCELERATORS↗

Effects of Energy Chirp on Echo-Enabled Harmonic Generation Free-Electron Lasers

We study effects of energy chirp on echo-enabled harmonic generation (EEHG). Analytical expressions are compared with numerical simulations for both harmonic and bunching factors. We also discuss the EEHG free-electron laser bandwidth increase due to an energy-modulated beam and its pulse length dependence on the electron energy chirp.

43 PARTICLE ACCELERATORS↗

Measurements and Simulations of Ultra-Low Emittance and Ultra-Short Electron Beams in the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is an x-ray Free-Electron Laser (FEL) project presently in a commissioning phase at SLAC. We report here on very low emittance measurements made at low bunch charge, and a few femtosecond bunch length produced by the LCLS bunch compressors. Start-to-end simulations associated with these beam parameters show the possibilities of generating hundreds of GW at 1.5 {angstrom} x-ray wavelength and nearly a single longitudinally spike at 1.5 nm with 2-fs duration.

43 PARTICLE ACCELERATORS↗

Synthesis and Crystallographic Analysis of 5-Se-Thymidine DNAs

We investigated the possibility of the interaction of 5-CH3 of thymidine and its 5?-phosphate backbone (C-H O-PO3 interaction) in DNA via the insertion of the atomic probe (a selenium atom) into the exo-5-position of thymidine (5-Se-T). 5-Se-T was synthesized for the first time, via Mn(OAc)3 assisted electrophilic addition of CH3SeSeCH3 to 3?,5?-di-O-benzoyl-2?-deoxyuridine. The 5-Se-T phosphoramidite was subsequently synthesized and incorporated into DNA in over 99% coupling yield. Biophysical and structural investigations of the 5-Se-T DNAs revealed that the Se-modified and nonmodified DNAs are virtually identical. In addition, the crystallographic analysis of a 5-Se-T DNA strongly suggests a hydrogen-bond formation between the 5-CH3 and 5?-phosphate groups (CH3 PO4- interaction).

59 BASIC BIOLOGICAL SCIENCES↗