Engineering Papers⌕ Search

Engineering topics

Huang, Z

Publications and source records attributed to Huang, Z.

At least 37 records · Page 2

WE-EF-303-11: Activity Distributions of Positron-Emitting-Isotopes Activated by Modulated Spot-Scanning Particle Beams

Purpose: To present the characteristics of positron-emitting-isotope (PEI) activity distributions on homogeneous and CIRS thorax phantoms irradiated by modulated spot-scanning carbon-ions and protons in Siemens IONTRIS system. Methods and Materials: Cylindrical homogeneous wax was irradiated by carbon-ions and protons of 10cm uniform square field with single-energy-layer ranges of 7cm, 16cm and 29cm. Images of PEI distributions were acquired over a period of 30 minutes at 10 minutes after each irradiation. Optimized uniform biological-equivalent doses of carbon-ions over a 5.0cm spherical target was delivered to CIRS phantom. Doses with range shifts in depths from 1mm to 6mm were also calculated and delivered to evaluate the accuracy of measuring activated PEI distributions. Results: Activated PEI distribution on homogeneous phantoms showed sharper peak near distal edge with flatter distribution toward proximal depth by carbon-ions than by protons. For depths near at Bragg-peak, penetration-depth spreading for energies from 10MeV/u to 60 MeV/u are from 0.4mm to 10.3mm, and 1.2mm to 30.4mm for projectile-fragments by carbon-ions and target-fragments by protons, respectively. For depths proximal to Bragg-peak, target-fragments for both carbon-ions and protons had minimal energy dependence in depth. For complex dose distributions delivered to CIRS thorax phantom, similar PEI peak-like distributions were still observed for carbon-ions. And, the changes at locations and edges of measured PEI peak were correlated within 0.5mm of shifted ranges. Mean activities over 5.0cm spherical target were similar for CISR phantom irradiated by doses with various range shifts. Conclusions: Peak-like PEI distributions by carbon-ions with good correlation to distal edges in both homogeneous and CIRS thorax phantoms present the potential for the in-vivo range verification while additional efforts is needed for protons. Due to flat distributions for depths at 6mm proximal to distal edges, mean activity at target might be used for in-vivo dose verification of target.

60 APPLIED LIFE SCIENCES↗

SU-E-T-154: Establishment and Implement of 3D Image Guided Brachytherapy Planning System

Purpose: Cannot observe the dose intuitionally is a limitation of the existing 2D pre-implantation dose planning. Meanwhile, a navigation module is essential to improve the accuracy and efficiency of the implantation. Hence a 3D Image Guided Brachytherapy Planning System conducting dose planning and intra-operative navigation based on 3D multi-organs reconstruction is developed. Methods: Multi-organs including the tumor are reconstructed in one sweep of all the segmented images using the multiorgans reconstruction method. The reconstructed organs group establishs a three-dimensional visualized operative environment. The 3D dose maps of the three-dimentional conformal localized dose planning are calculated with Monte Carlo method while the corresponding isodose lines and isodose surfaces are displayed in a stereo view. The real-time intra-operative navigation is based on an electromagnetic tracking system (ETS) and the fusion between MRI and ultrasound images. Applying Least Square Method, the coordinate registration between 3D models and patient is realized by the ETS which is calibrated by a laser tracker. The system is validated by working on eight patients with prostate cancer. The navigation has passed the precision measurement in the laboratory. Results: The traditional marching cubes (MC) method reconstructs one organ at one time and assembles them together. Compared to MC, presented multi-organs reconstruction method has superiorities in reserving the integrality and connectivity of reconstructed organs. The 3D conformal localized dose planning, realizing the 'exfoliation display' of different isodose surfaces, helps make sure the dose distribution has encompassed the nidus and avoid the injury of healthy tissues. During the navigation, surgeons could observe the coordinate of instruments real-timely employing the ETS. After the calibration, accuracy error of the needle position is less than 2.5mm according to the experiments. Conclusion: The speed and quality of 3D reconstruction, the efficiency in dose planning and accuracy in navigation all can be improved simultaneously.

60 APPLIED LIFE SCIENCES↗

SU-E-T-352: Why Is the Survival Rate Low in Oropharyngeal Squamous Cell Carcinoma?

Purpose: Tumors are composed of a large number of clonogens that have the capability of indefinite reproduction. Even when there is complete clinical or radiographic regression of the gross tumor mass after treatment, tumor recurrence can occur if the clonogens are not completely eradicated by radiotherapy. This study was to investigate the colonogen number and its association with the tumor control probability (TCP) in oropharyngeal squamous cell carcinoma (OSCCA). Methods: A literature search was conducted to collect clinical information of patients with OSCCA, including the prescription dose, tumor volume and survival rate. The linear-quadratic (LQ) model was incorporated into TCP model for clinical data analysis. The total dose ranged from 60 to 70 Gy and tumor volume ranged from 10 to 50 cc. The TCP was calculated for each group according to tumor size and dose. The least χ{sup 2} method was used to fit the TCP calculation to clinical data while other LQ model parameters (α, β) were adopted from the literature, due to the limited patient data. Results: A total of 190 patients with T2–T4 OSCCA were included. The association with HPV was not available for all the patients. The 3-year survival rate was about 82% for T2 squamous cell carcinoma and 40% for advanced tumors. Fitting the TCP model to the survival data, the average clonogen number was 1.56×10{sup 12}. For the prescription dose of 70 Gy, the calculated TCP ranged from 40% to 90% when the tumor volume varied from 10 to 50 cc. Conclusion: Our data suggests variation between the clonogen number and TCP in OSCCA. Tumors with larger colonogen number tend to have lower TCP and therefore dose escalation above 70 Gy may be indicated in order to improve the TCP and survival rate. Our result will require future confirmation with a large number of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis Structure and Imaging of Oligodeoxyribonucleotides with Tellurium-nucleobase Derivatization

We report here the first synthesis of 5-phenyl-telluride-thymidine derivatives and the Te-phosphoramidite. We also report here the synthesis, structure and STM current-imaging studies of DNA oligonucleotides containing the nucleobases (thymine) derivatized with 5-phenyl-telluride functionality (5-Te). Our results show that the 5-Te-DNA is stable, and that the Te-DNA duplex has the thermo-stability similar to the corresponding native duplex. The crystal structure indicates that the 5-Te-DNA duplex structure is virtually identical to the native one, and that the Te-modified T and native A interact similarly to the native T and A pair. Furthermore, while the corresponding native showed weak signals, the DNA duplex modified with electron-rich tellurium functionality showed strong topographic and current peaks by STM imaging, suggesting a potential strategy to directly image DNA without structural perturbation.

59 BASIC BIOLOGICAL SCIENCES↗

Generation of Intense Attosecond X-Ray Pulses Using Ultraviolet Laser Induced Microbunching in Electron Beams

We propose a scheme that combines the echo-enabled harmonic generation technique with the bunch compression and allows one to generate harmonic numbers of a few hundred in a microbunched beam through up-conversion of the frequency of an ultraviolet seed laser. A few-cycle intense laser is used to generate the required energy chirp in the beam for bunch compression and for selection of an attosecond x-ray pulse. Sending this beam through a short undulator results in an intense isolated attosecond x-ray pulse. Using a representative realistic set of parameters, we show that 1 nm x-ray pulse with peak power of a few hundred MW and duration as short as 20 attoseconds (FWHM) can be generated from a 200 nm ultraviolet seed laser. The proposed scheme may enable the study of electronic dynamics with a resolution beyond the atomic unit of time ({approx}24 attoseconds) and may open a new regime of ultrafast sciences.

43 PARTICLE ACCELERATORS↗

Ideas for a Future PEP-X Light Source

SLAC is developing a long-range plan to transfer the evolving scientific programs at SSRL from the SPEAR3 light source to a much higher performing synchrotron source -- PEP-X -- a new storage ring that would occupy the existing PEP-II tunnel and support two experimental halls, each containing 16 x-ray beam lines. Operating at 4.5 GeV and 1.5 A with a horizontal emittance of 0.14 nm-rad, reached using 90 m of damping wigglers, PEP-X would have an order of magnitude higher average brightness and flux in the 1-{angstrom} x-ray range than any existing or planned future storage ring sources. Higher brightness in the soft x-ray regime might be reached with partial lasing in long undulators, and high peak brightness could be reached with seeded FEL emission. The status of preliminary studies of PEP-X is presented.

43 PARTICLE ACCELERATORS↗

Waveguide Structures for RF Undulators with Applications to FELs and Storage Rings

RF undulators, suggested a long time ago, have the advantage of fast dynamic control of polarization, undulator strength and wavelength. However, RF undulators require very strong RF fields in order to produce radiation of the same order as conventional static devices. Very high power RF energy confined inside a waveguide or a cavity can provide the necessary RF fields to undulate the electron beam. However, the wall losses in the waveguide should be low enough to make it practically feasible as a CW or quasi CW undulator and, hence, competitive with static devices for applications to storage rings and FELs. Here we present various waveguide structures such as smooth walled and corrugated walled waveguides and various RF modes. We will show that there are some advantages in operating with higher order modes and also with hybrid modes in the corrugated guide. We will show that the RF power requirement for some of these modes will permit a quasi CW operation of the undulator, thus permitting its operation in a storage ring.

43 PARTICLE ACCELERATORS↗

A Single-Shot Method for Measuring Femtosecond Bunch Length in Linac-Based Free-Electron Lasers

There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith [Phys. Rev. ST Accel. Beams 3, 032801 (2000)], we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent synchrotron radiation and longitudinal space charge. When used in conjunction with a high-resolution electron spectrometer, this method potentially reveals the temporal profile of the electron beam down to the femtosecond and subfemotsecond scale.

43 PARTICLE ACCELERATORS↗

Free electron lasers: Present status and future challenges

With the scientific successes of the soft X-ray FLASH facility in Germany and the recent spectacular commissioning of the Linac Coherent Light Source at SLAC, free electron lasers are poised to take center stage as the premier source of tunable, intense, coherent photons of either ultra-short time resolution or ultra-fine spectral resolution, from the far infrared to the hard X-ray regime. This paper examines the state of the art in FEL performance and the underlying enabling technologies. It evaluates the state of readiness of the three basic machine architectures—SASE FELs, seeded FELs, and FEL oscillators—for the major X-ray science user facilities on the 5–10 years time scale and examines the challenges that lie ahead for FELs to achieve their full potential throughout the entire spectral range. In soft and hard X-rays, high longitudinal coherence, in addition to full transverse coherence, will be the key performance upgrade; ideas using laser-based or self-seeding or oscillators can be expected to be qualitatively superior to today's SASE sources. Short pulses, from femtoseconds to attoseconds, can be realistically envisioned. With high repetition rate electron sources coupled to superconducting radiofrequency linear accelerators, unprecedented average beam brightness will be possible and many users would be served simultaneously by a single accelerator complex.

43 PARTICLE ACCELERATORS↗