Engineering Papers⌕ Search

Engineering topics

Huang, Z

Publications and source records attributed to Huang, Z.

66 records · Page 4

Measurements and Modeling of Coherent Synchrotron Radiation and its Impact on the LCLS Electron Beam

In order to reach the high peak current required for an x-ray free electron laser, two separate magnetic dipole chicanes are used in the Linac Coherent Light Source (LCLS) accelerator to compress the electron bunch length in stages. In these bunch compressors, coherent synchrotron radiation (CSR) can be emitted either by a short electron bunch or by any longitudinal density modulation that may be on the bunch. In this paper, we report detailed measurements of the CSR-induced energy loss and transverse emittance growth in these compressors. Good agreement is found between the experimental results and multi-particle tracking studies. We also describe direct observations of CSR at optical wavelengths and compare with analytical models based on beam microbunching.

43 PARTICLE ACCELERATORS↗

Generation of attosecond x-ray pulses with a multi-cycle two-color ESASE scheme

Generation of attosecond x-ray pulses is attracting much attention within the x-ray free-electron laser (FEL) user community. Several schemes have been proposed based on manipulations of electron bunches with extremely short laser pulses. In this paper, we extend the attosecond two-color ESASE scheme proposed by Zholents et al. to the long optical cycle regime using a detuned second laser and a tapered undulator. Both lasers can be about ten-optical-cycles long, with the second laser frequency detuned from the first one to optimize the contrast between the central and side current spikes. A tapered undulator mitigates the degradation effect of the longitudinal space charge (LSC) force in the undulator and suppresses the FEL gain of all side current spikes. Simulations using the LCLS parameters show a single attosecond x-ray spike of {approx} 110 attosecond can be produced with a good contrast ratio.

43 PARTICLE ACCELERATORS↗

Three-Dimensional Analysis of Longitudinal Space Charge Microbunching Starting From Shot Noise

The commissioning of the Linac Coherent Light Source (LCLS) injector showed unexpected coherent optical transition radiation (COTR) for an uncompressed electron bunch downstream of a dog-leg transport line. In this paper, we develop a three-dimensional analysis of longitudinal space charge microbunching to explain the phenomenon. Our analysis takes into account the transverse correlation of the longitudinal space charge field due to shot-noise startup and finite observation angles of the radiation. We also apply this analysis to the LCLS COTR observations.

43 PARTICLE ACCELERATORS↗

Observation of Coherent Optical Transition Radiation in the LCLS Linac

The beam diagnostics in the linac for the Linac Coherent Light Source (LCLS) X-ray FEL project at SLAC includes optical transition radiation (OTR) screens for measurements of transverse and longitudinal beam properties. We report on observations of coherent light emission from the OTR screens (COTR) at visible wavelengths from the uncompressed and compressed electron beam at various stages in the accelerator.

43 PARTICLE ACCELERATORS↗

Commissioning of the LCLS Linac and Bunch Compressors

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) project under construction at SLAC [1]. The injector section, from drive-laser and RF photocathode gun through the first bunch compressor, was commissioned in the spring and summer of 2007. The second phase of commissioning, including the second bunch compressor and various main linac modifications, was completed in January through August of 2008. We report here on experience gained during this second phase of machine commissioning, including the injector, the first and second bunch compressor stages, the linac up to 14 GeV, and beam stability measurements. The final commissioning phase, including the undulator and the long transport line from the linac, is set to begin in December 2008, with first light expected in July 2009.

43 PARTICLE ACCELERATORS↗

Microbunching and Beam Break Up in DUV FEL Accelerator

We present the results of electron beam longitudinal modulation studies in the DUV-FEL accelerator. For bunch length determination we used the 'zero-phasing' method, based on a measurement of the chirped electron bunch energy spectra. The measurements revealed a spiky structure in the longitudinal phase space [1]. A model based on space charge effect is considered [2] to explain of the obtained phenomena. The analysis of the energy spectra has shown a sensitivity of the structure to the electron beam peak current, energy and longitudinal non-uniformity of the RF gun drive laser. Analytical calculations have demonstrated a qualitative agreement with experimental observations. Several experiments have been made to compare with theory; measured results are reviewed in this paper. The obtained effect is briefly discussed in relation to high brightness accelerators.

43 PARTICLE ACCELERATORS↗

Derivatization of DNAs with Selenium at 6-Position of Guanine for Function and Crystal Structure Studies

To investigate nucleic acid base pairing and stacking via atom-specific mutagenesis and crystallography, we have synthesized for the first time the 6-Se-deoxyguanosine phosphoramidite and incorporated it into DNAs via solid-phase synthesis with a coupling yield over 97%. We found that the UV absorption of the Se-DNAs red-shifts over 100 nm to 360 nm ({Epsilon} = 2.3 x 10{sup 4} M{sup -1} cm{sup -1}), the Se-DNAs are yellow colored, and this Se modification is relatively stable in water and at elevated temperature. Moreover, we successfully crystallized a ternary complex of the Se-G-DNA, RNA and RNase H. The crystal structure determination and analysis reveal that the overall structures of the native and Se-modified nucleic acid duplexes are very similar, the selenium atom participates in a Se-mediated hydrogen bond (Se H-N), and the {sup Se}G and C form a base pair similar to the natural G-C pair though the Se-modification causes the base-pair to shift (approximately 0.3 {angstrom}). Our biophysical and structural studies provide new insights into the nucleic acid flexibility, duplex recognition and stability. Furthermore, this novel selenium modification of nucleic acids can be used to investigate chemogenetics and structure of nucleic acids and their protein complexes.

08 HYDROGEN↗

Commissioning Results of the LCLS Injector

The Linac Coherent Light Source (LCLS) is a SASE xray Free-Electron Laser (FEL) project presently under construction at SLAC. The injector section, from drive-laser and RF photocathode gun through first bunch compressor chicane, was installed in fall 2006. Initial system commissioning with an electron beam has recently been completed. The second phase of construction, including second bunch compressor and full linac, is planned for 2008. In this paper, we report experimental results and experience gained during the first phase of machine commissioning. This includes the cathode, drive laser, RF photocathode gun, linac booster section, S-band and X-band RF systems, first bunch compressor, and the various beam diagnostics.

43 PARTICLE ACCELERATORS↗

Measurements of Compression and Emittance Growth after the First LCLS Bunch Compressor Chicane

The Linac Coherent Light Source (LCLS) is a SASE xray free-electron laser project presently under construction at SLAC. The injector section from RF photocathode gun through first bunch compressor chicane was installed during the fall of 2006. The first bunch compressor is located at 250 MeV and nominally compresses a 1-nC electron bunch from an rms length of about 1 mm to 0.2 mm. Transverse phase space and bunch length diagnostics are located immediately after the chicane. We present preliminary measurements and simulations of the longitudinal and transverse phase space after the chicane in various beam conditions, including extreme compression with micron-scale current spikes.

43 PARTICLE ACCELERATORS↗

Initial Commissioning Experience With the LCLS Injector

The Linac Coherent Light Source (LCLS) is a SASE xray Free-Electron Laser (FEL) project presently under construction at SLAC [1]. The injector section, from drive-laser and RF photocathode gun through first bunch compressor chicane, was installed in fall 2006. Initial system commissioning with an electron beam is taking place during the spring and summer of 2007. The second phase of construction, including second bunch compressor and full linac, will begin later, in the fall of 2007. We report here on experience gained during the first phase of machine commissioning, including RF photocathode gun, linac booster section, S-band and X-band RF systems, first bunch compressor, and the various beam diagnostics.

43 PARTICLE ACCELERATORS↗

Analysis of Slice Transverse Emittance Evolution ina Photocathode RF Gun

The slice transverse emittance of an electron beam is of critical significance for an x-ray FEL. In a photocathode RF gun, the slice transverse emittance is not only determined by the emission process, but also influenced strongly by the non-linear space charge effect. In this paper, we study the slice transverse emittance evolution in a photocathode RF gun using a simple model that includes effects of RF acceleration, focusing, and space charge force. The results are compared with IMPACT-T space charge simulations and may be used to understand the development of the slice emittance in an RF gun.

43 PARTICLE ACCELERATORS↗

Steady State Analysis of Short-wavelength, High-gainFELs in a Large Storage Ring

Storage ring FELs have operated successfully in the low-gain regime using optical cavities. Discussions of a high-gain FEL in a storage ring typically involve a special bypass to decouple the FEL interaction from the storage ring dynamics. In this paper, we investigate the coupled dynamics of a high-gain FEL in a large storage ring such as PEP and analyze the equilibrium solution. We show that an FEL in the EUV and soft x-ray regimes can be integrated into a very bright storage ring and potentially provides three orders of magnitude improvement in the average brightness at these radiation wavelengths. We also discuss possibilities of seeding with HHG sources to obtain ultra-short, high-peak power EUV and soft x-ray pulses.

43 PARTICLE ACCELERATORS↗