At least 19 records

Cirrus-cloud thermostat for tropical sea surface temperature tested using satellite data

Cirrus clouds associated with tropical convection may shield the ocean from sunlight and therefore act as a thermostat to limit tropical SST (sea surface temperature) to less than 305 K. This hypothesis was tested using satellite radiance data. It was found that changes in the properties of cirrus clouds do not seem to be related to changes in SSTs. During the 1987 El Nino event large-scale atmospheric circulation changes rather than the direct effect of SSTs seemed to control large-scale changes in radiative effects of cirrus clouds. If averaged over the entire tropical Pacific, increases in surface evaporative cooling are stronger than decreases in solar heating owing to cirrus cloud variation. This would indicate that there is no cirrus cloud thermostat to tropical SSTs.

Fu, Rong↗

CRYOSTAT (18-IML-1)

The CRYOSTAT is an autonomously working rack mounted equipment. It provides two thermostat chambers, independently controlled by a processor via on/off switching of the current through peltier elements. The temperature profiles of the freezer and stabilizer are subdivided in a common number of steps, each one with a preprogrammable temperature gradient or at constant temperature. Core parameters can be reprogrammed by crew interaction in case of rescheduling the CRYOSTAT operation time due to changed mission requirements or contingency. Actions of the CRYOSTAT (e.g., opening the slide), the steps, actual temperature of the thermostat chambers, experiment time, and the housekeeping data are recorded on a built-in RAM and a tape. In each thermostat chamber, a specific sample container can be inserted which consists of a transparent Plexiglas block accommodating seven crystallization experiments.

Source record↗

Mechanisms Regulating Deep Moist Convection and Sea-Surface Temperatures of the Tropics

Despite numerous previous studies, two relationships between deep convection and the sea-surface temperature (SST) of the tropics remain unclear. The first is the cause for the sudden emergence of deep convection at about 28 deg SST, and the second is its proximity to the highest observed SST of about 30 C. Our analysis provides a rational explanation for both by utilizing the Improved Meteorological (IMET) buoy data together with radar rainfall retrievals and atmospheric soundings provided by the Tropical Ocean Global Atmosphere Coupled Ocean-Atmosphere Response Experiment (TOGA-COARE). The explanation relies on the basic principles of moist convection as enunciated in the Arakawa-Schubert cumulus parameterization. Our analysis shows that an SST range of 28-29 C is necessary for "charging" the atmospheric boundary layer with sufficient moist static energy that can enable the towering convection to reach up to the 200 hPa level. In the IMET buoy data, the changes in surface energy fluxes associated with different rainfall amounts show that the deep convection not only reduces the solar flux into the ocean with a thick cloud cover, but it also generates downdrafts which bring significantly cooler and drier air into the boundary-layer thereby augmenting oceanic cooling by increased sensible and latent heat fluxes. In this way, the ocean seasaws between a net energy absorber for non-raining and a net energy supplier for deep-convective raining conditions. These processes produce a thermostat-like control of the SST. The data also shows that convection over the warm pool is modulated by dynamical influences of large-scale circulation embodying tropical easterly waves (with a 5-day period) and MJOs (with 40-day period); however, the quasi-permanent feature of the vertical profile of moist static energy, which is primarily maintained by the large-scale circulation and thermodynamical forcings, is vital for both the 28 C SST for deep convection and its upper limit at about 30 C.

Sud, Y. C.↗

Dendritic solidification under microgravity conditions

The Isothermal Dendritic Growth Experiment is undergoing development in cooperation with NASA-Lewis in order to test dendritic growth theory at small supercoolings in low earth orbit. The apparatus encompasses four major subsystems: a temperature-controlled thermostatic bath capable of millikelvin stability, a photographic data collection system, a crystal-growth chamber, and a start-detection system which initiates data collection. Comparisons are made with ground-based study methods for dendritic growth.

Glicksman, M. E.↗

Programmable Thermostats for MPLM Shell Heater Control ULF1: Thermal Performances - 1

The Multi-Purpose Logistics Module (MPLM) is the primary carrier for "pressurized" logistics to and from the International Space Station (ISS). The MPLM is transported in the payload bay of the Space Shuttle and is docked to the ISS for unloading, and reloading, of contents within the ISS shirt sleeve environment. Foil heaters, controlled originally with bi-metallic thermostats, are distributed across the outside of the MPLM structure and are utilized to provide energy to the structure to avoid exposure to cold temperatures and prevent condensation. The existing bi-metallic, fixed temperature set point thermostats have been replaced with Programmable Thermostats Modules (PTMs) in the Passive Thermal Control Subsystem (PTCS) 28Vdc shell heater circuits. The goal of using the PTM thermostat is to improve operational efficiency of the MPLM on-orbit shell heaters by providing better shell temperature control via feedback control capability. Each heater circuit contains a programmable thermostat connected to an external temperature sensor, a Resistive Temperature Device (RTD), which is used to provide continuous temperature monitoring capability. Each thermostat has programmable temperature set points and control spans. The data acquisition system uses a standard RS-485 serial interface communications cable to provide digital control capability. The PTM system was designed by MSFC, relying upon ALTEC support for their integration within the MPLM system design, while KSC performed the installation and ground checkout testing of the thermostat and RS-485 communication cable on the MPLM FM1 flight module. The PTMs were used for the first time during the STS-121/ULF1.1 mission. This paper will describe the design, development and verification of the PTM system, as well as the PTM flight performance and comparisons with SINDA thermal model predictions.

Glasgow, Shaun↗

A facility for precise temperature control applications in microgravity

The general design, main components, and operation of the isothermal dendritic growth apparatus (IDGA) designed for microgravity experimentation are described. The four major subsystems of the IDGA are a temperature controlled thermostatic bath capable of milli-kelvin stability, a photographic data collection system, a crystal growth chamber, and a growth detection system to initiate data collection. Some of the specific experiments that could utilize the capabilities of the IDGA are dendritic growth in alloys, monotectic systems, life science experiments, and technological applications.

Glicksman, M. E.↗

Isothermal dendritic growth - A proposed microgravity experiment

This paper describes an isothermal dendritic growth experiment (IDGE), a microgravity-oriented spaceborne scientific experiment designed to obtain 'convection-free' dendritic growth and thereby provide a test of dendritic growth theory. The apparatus includes a controlled thermostatic bath capable of providing + or - 2 mK stability, a photographic data collection system, a crystal growth chamber ensuring 'free' dendritic growth, and an optical RAM camera for crystal growth detection. The experiment will be carried on essentially automatically aboard the Materials Science Laboratory in the cargo bay of the Space Shuttle. The results of preliminary ground-based studies are presented.

Glicksman, M. E.↗

THE DENSITIES OF SATURATED LIQUID HYDROGEN

This laboratory is engaged in a programme for the determination of thermostatic, thermodynamic, and transport properties of para-hydrogen, emphasizing high densities. Reported here are new data for the density of saturated liquid pura-hydrogen from boiling point to critical point. A review of hydrogen properties includes densities of normal hydrogen from triple to critical points and of pura-hydrogen up to the boiling point? More recent determinations of vapour pressures and critical constants have been made for both hydrogen modification.

LIQUID HYDROGEN↗

System for Testing Thermal Insulation of Pipes

An apparatus and method have been developed for measuring the rates of leakage of heat into pipes carrying liquids, the purpose of the measurements being to quantify the thermal performance of the insulation system. The apparatus is designed primarily for testing pipes used to carry cryogenic liquids, but can also be used for measuring the thermal performance of other insulated pipes or piping systems. The basic measurement principle is straightforward: The outer surface of the pipe insulation is maintained at a fixed warmer temperature. The interior of the pipe is maintained in a narrow fixed lower-temperature range by means of a regular liquid (e.g., water) that is pumped through the pipe at a known flow rate or a cryogenic liquid (e.g., nitrogen) that is saturated at atmospheric pressure and replenished until steady-state conditions are achieved. In the case of water or another liquid pumped through, the inlet and outlet temperatures are measured and heat-leak power is calculated as the mass flow rate of the liquid multiplied by the specific heat of the liquid multiplied by the inlet-to-outlet temperature rise of the liquid. In the case of liquid nitrogen or another low-temperature boiling liquid, the heat-leak power is calculated as the rate of boil-off multiplied by the latent heat of vaporization of the liquid. Then the thermal-insulation performance of the pipe system can be calculated as a function of the measured heat-leak power, the inner and outer boundary temperatures, and the dimensions of the pipe. The apparatus can test as many as three pipes simultaneously. The pipes can have inner diameters up to .15 cm and outer diameters up to .20 cm. The lengths of the pipes may vary; typical lengths are of the order of 18 m. Two thermal guard boxes . one for each end of the pipe(s) under test . are used to make the inlet and outlet fluid connections to the pipe(s) (see figure). The connections include bellows that accommodate thermal expansion and contraction of the pipes. The guard boxes and pipe(s) are positioned so that the pipe(s) slope upward from the upstream to the downstream end at an angle of at least 2 . The upward slope allows vapor bubbles to accumulate at the downstream end. The thermal guard boxes keep the ends of the pipes at the lower interior temperature to prevent spurious lengthwise leakage of heat into the pipes. It is important to prevent this spurious heat leakage because, if it were allowed to occur, it could contribute a large error in the measured heat-leak power. The upstream thermal guard box includes a heat exchanger through which liquid flowing into the pipe(s) is subcooled to the saturation temperature corresponding to the ambient pressure. Conversely, this heat exchanger can also be used to warm the flowing liquid to a desired fixed temperature. The apparatus includes a temperature control device that is placed around each pipe under test. Each device is operated under thermostatic control to maintain the outer surface of the pipe insulation at the specified test temperature. All measurements are recorded on a portable data-acquisition system.

Fesmire, James E.↗

Programmable Thermostat Module Upgrade for the Multi-Purpose Logistics Module

The STS-121/ULF1.1 mission was the maiden flight of the Programmable Thermostat Module (PTM) system used to control the 28 V shell heaters on the Multi-Purpose Logistics Module (MPLM). These PTMs, in conjunction with a Data Recorder Module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This paper will discuss the hardware design, development, test and verification (DDT&V) activities performed at the Marshall Space Flight Center (MSFC) as well as the operational implementation and mission performance.

Clark, Dallas↗

Programmable Thermostat Module Upgrade for the Multipurpose Logistics Module

The STS-121/ULF 1.1 mission was the maiden flight of the programmable thermostat module (PTM) system used to control the 28 V shell heaters on the multi-purpose logistics module (MPLM). These PTMs, in conjunction with a data recorder module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This Technical Memorandum discusses the hardware design, development, test, and verification (DDT&V) activities performed at the Marshall Space Flight Center as well as the operational implementation and mission performance.

Clark, D. W.↗

CO2 cooling in terrestrial planet thermospheres

We examine the recent progress in the debate on the CO2-O relaxation rate, its temperature dependence, and its corresponding impact on the thermospheric heat budgets of Venus, Earth, and Mars. This comparative approach provides the broadest range of conditions under which a common CO2-O relaxation rate should provide consistent results. New global mean calculations are presented for the heat budgets of these three planets using large CO2-O relaxation rates that have been inferred recently from Earth CO2 radiance measurements and laboratory studies. Results indicate that available Venus and Mars data constrain the CO2-O relaxation rate to be 2-4 x 10(exp -12)/cu cm/s at 300 K. For Venus, this strong cooling serves as an effective thermostat that gives rise to a small variation of thermospheric temperatures over the solar cycle, just as observed. Conversely, CO2 cooling does not appear to be dominant in the dayside heat budget of the Mars thermosphere over most of the solar cycle. For the Earth, this strong cooling implies that the lower thermosphere does not typically require significant eddy diffusion or heat conduction. However, global-scale dynamics or an additional heating mechanism may be needed to restore calculated temperatures to observed values when relaxation rates exceeding 2 x 10(exp -12)/cu cm/s are employed.

Bougher, S. W.↗

Compressibility measurements of gases using externally heated pressure vessels.

Most of the data collected under conditions of high temperature and pressure have been determined using a thick-walled bomb of carefully measured and fixed volume which is externally heated by an electric furnace or a thermostatically controlled bath. There are numerous variations on the basic method depending on the pressure-temperature range of interest, and the particular gas or gas mixture being studied. The construction and calibration of the apparatus is discussed, giving attention to the pressure vessel, the volume of the bomb, the measurement of pressure, the control and measurement of temperature, and the measurement of the amount and composition of gas in the bomb.

Presnall, D. C.↗

Air Force Logistics Command (AFLC) solar thermal plant

The plant proved its capability to deliver the desired energy product in a USAF industrial environment. The collector proved capable of energy conversion at insolation levels up to 25% below design minimum. The plant and the project were negatively affected by severe winter weather, with total insolation during the test period 60 percent less than the expected value. Environmental effects reduced plant availability to 55 percent. Only five, minimally good operating days were experienced during the test period. The subsequent lack of performance data prohibits the drawing of general conclusions regarding system performance. System operability was rated generally high. The only inhibiting factor was the difficulty in procuring replacement parts for rapid repair under USAF stockage and procurement policies. No inherently serious system failures were recorded, although a thermostatic valve malfunction in the freeze protection system ultimately took 30 days to repair.

Source record↗

Critical fluid light scattering

Thermal fluctuations give rise to a host of thermodynamic anomalies near critical points. The background for these phenomena is presented, and an experimental design on STS flight experiment called Zeno is described. The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments have been limited on Earth by the presence of gravity, which causes large density gradients in the sample. Fluctuation decay rates in xenon will be measured at least 100 times closer to the critical point than is possible on Earth. This will require taking data as close as 145 micro K to the critical temperature, after locating it to + or - 10 micro K. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. An essential part of the apparatus is the thermostat. Its design principles and key features are given together with some observed performance characteristics of a prototype: + or - 20 micro K stability for 18 hours, and one minute programmed step response for steps less than 10 mK.

Gammon, Robert W.↗

Critical fluid light scattering

Thermal fluctuations give rise to a host of thermodynamic anomalies near critical points. The background for these phenomena is presented, and an experiment design on STS flight experiment called 'Zeno' described. The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light-scattering and photon-correlation spectroscopy. Such experiments have been limited on earth by the presence of gravity, which causes large density gradients in the sample. Fluctuation decay rates in xenon will be measured at least 100 times closer to the critical point than is possible on earth. This will require taking data as close as 145 microK to the critical temperature (Tc = 289.72 K), after locating it to + or - 10 microK. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. An essential part of the apparatus is the thermostat. Its design principles and key features are given together with some observed performance characteristics of a prototype: + or - 20 microK stability for 18 hours, and one minute programmed step response for steps less than 10 mK.

Gammon, Robert W.↗

The preliminary design of an orbiting observatory - The Space Telescope

The systems and subsystems of the Space Telescope proposed for an orbiting observatory to be launched by the Space Shuttle in the 1980s are described. The structural design is simple and based on existing technologies for high reliability. Provisions are made for on-orbit servicing and maintenance. All deployable appendages are designed for manual override to insure retrieval and return of the Space Telescope to earth for major refurbishing, which should occur at intervals of not less than six years. Low performance risk, passive techniques are used in the thermal control subsystem to provide a cold-biased design with thermostatically controlled heaters to adjust temperature. The electrical power system utilizes NASA Standard Hardware - 50 ampere hour nickel-cadmium battery cells, a standard power regulator unit, and a flight-proven flexible rollup solar array with high-efficiency (12.5 per cent) silicon solar cells. The communication subsystem is designed for compatibility with the Tracking and Data Relay Satellite System. The pointing control system will have a maximum line of sight variation of 0.007 arc seconds. The telescope optics are a Ritchey-Chretien version of the Cassegrain configuration.

Timmons, K. P.↗

Safety considerations in the design of Spacelab refrigerator/freezer

A vapor compression refrigerator/freezer has been designed for Spacelab to conduct life sciences experiments. It is equipped with different safety features to eliminate all probable types of failures. The whole Freon loop is enclosed in a second containment so that any leakage of Freon can be contained. The unit is provided with an 'Emergency On' switch to actuate during backup mode which provides the spacecraft power directly to the compressor and the cooling fans while removing the power supply and all normal control elements from the circuit. During this mode, the compressor runs continuously when operating as a freezer (-22 C) and is controlled by a thermostat to cycle when operating as a refrigerator (4 C). It has a push button switch at the front panel to momentarily power the thermometer by a battery to monitor the inside temperature during an emergency. It has a door switch which shuts off the internal cooling fans when the door is opened. All the important critical performance data will be downlinked through a data connector to monitor during mission.

Hye, A.↗