Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rotating target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rotating Target Development for SNS Second Target Station

A rotating target for the second target station (STS) at SNS has been identified as an option along with a mercury target. Evaluation of the rotating target alternative for STS has started at 1.5 MW which is considered an upper bound for the power. Previous preconceptual design work for a 3 MW rotating target is being modified for the lower power level. Transient thermal analysis for a total loss of active water cooling has been done for a simplified 2D model of the target and shielding monolith which shows that peak temperatures are well below the level at which tungsten vaporization by steam could exceed site boundary dose limits. Design analysis and integration configuration studies have been done for the target-moderator-reflector assembly which maximizes the number of neutron beam lines and provides for replacement of the target and moderators. Target building hot cell arrangement for this option will be described. An option for operation in rough vacuum without a proton beam window using Ferro fluid seals on a vertical shaft is being developed. A full scale prototypic drive module based on the 3 MW preconceptual design has been fabricated and successfully tested with a shaft and mock up target supplied by the ESS-Bilbao team. Overall planning leading to decision between mercury and the rotating target in 2011 will be discussed

43 PARTICLE ACCELERATORS↗

Neutronics analyses in support of rotating target developments at SNS

A second target station (STS) for Spallation Neutron Souce (SNS) very likely being operated in long-pulse mode is in the early design phase, will complement the ORNL neutron sources, which presently consist of a short-pulse spallation source and the HFIR research reactor. As an alternative to the stationary liquid metal target, a rotating target is being considered. Neutronics studies in support of a 3MW power 20 Hz repetition rate rotating target feasibility study funded through the laboratory LDRD program, was extended towards a 1.5 MW STS design. The scope of work included in-operation heat deposition rates in target structures for thermal and structural analyses, target radionuclide inventory for decay heat and safety analyses, lifetime estimations due to radiation-driven material damage of target and moderator components, moderator neutron performance and moderator cryogenic heatloads.

43 PARTICLE ACCELERATORS↗

3 MW Solid Rotating Target Design

A rotating solid target design concept is being developed for potential use at the second SNS target station (STS). A long pulse beam (~ 1 msec) at 1.3 GeV and 20 Hz is planned with power levels at or above 1 MW. Since the long pulse may give future opportunities for higher power, this study is looking at 3 MW to compare the performance of a solid rotating target to a mercury target. Unlike the case for stationary solid targets at such powers this study indicates that a rotating solid target, when used with large coupled hydrogen moderators, has neutronic performance equal to or better than that with a mercury target, and the solid target has a greatly increased lifetime. Design studies have investigated water cooled tungsten targets with tantalum cladding approximately 1.2 m in diameter, and 70mm thick. Operating temperatures are low ( < 150 C) with mid-plane, top and bottom surface cooling. In case of cooling system failure, the diameter gives enough surface area to remove the decay heat by radiation to the surrounding reflector assemblies while keeping the peak temperatures below approximately 700 C. This temperature should mitigate potential loss of coolant accidents and subsequent steam, tungsten interaction which has a threshold of approximately 800 C. Design layouts for the sealing systems and potential target station concepts have been developed.

rotating target↗

SECOND TARGET STATION MODERATOR PERFORMANCE WITH A ROTATING TARGET

Oak Ridge National Laboratory manages and operates the Spallation Neutron Source and the High Flux Isotope Reactor, two of the world's most advanced neutron scattering facilities. Both facilities are funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Science, and are available to researchers from all over the world. Delivering cutting edge science requires continuous improvements and development of the facilities and instruments. The SNS was designed from the outset to accommodate an additional target station, or Second Target Station (STS), and an upgraded accelerator feeding proton beams to STS and the existing First Target Station (FTS). Upgrade of the accelerator and the design and construction of STS are being proposed. The presently considered STS configuration is driven with short (<1 s) proton pulses at 10 Hz repetition rate and 467 kW proton beam power, and is optimized for high intensity and high resolution long wavelength neutron applications. STS will allow installation of 22 beamlines and will expand and complement the current national neutron scattering capabilities. In 2015 the STS studies were performed for a compact tungsten target; first a stationary tungsten plate target was analyzed to considerable details and then dropped in favor of a rotating target. For both target options the proton beam footprint as small as acceptable from mechanical and heat removal aspects is required to arrive at a compact-volume neutron production zone in the target, which is essential for tight coupling of target and moderators and for achieving high-intensity peak neutron fluxes. This paper will present recent STS work with the emphasis on neutronics and moderator performance.

long wavelength neutrons↗

Prototype Spallation Neutron Source Rotating Target Assembly Final Test Report

A full-scale prototype of an extended vertical shaft, rotating target assembly based on a conceptual target design for a 1 to 3-MW spallation facility was built and tested. Key elements of the drive/coupling assembly implemented in the prototype include high integrity dynamic face seals, commercially available bearings, realistic manufacturing tolerances, effective monitoring and controls, and fail-safe shutdown features. A representative target disk suspended on a 3.5 meter prototypical shaft was coupled with the drive to complete the mechanical tests. Successful operation for 5400 hours confirmed the overall mechanical feasibility of the extended vertical shaft rotating target concept. The prototype system showed no indications of performance deterioration and the equipment did not require maintenance or relubrication.

McManamy, Thomas J↗

Rotating cylindrical magnetron sputtering: Simulation of the reactive process

A rotating cylindrical magnetron consists of a cylindrical tube, functioning as the cathode, which rotates around a stationary magnet assembly. In stationary mode, the cylindrical magnetron behaves similar to a planar magnetron with respect to the influence of reactive gas addition to the plasma. However, the transition from metallic mode to poisoned mode and vice versa depends on the rotation speed. An existing model has been modified to simulate the influence of target rotation on the well known hysteresis behavior during reactive magnetron sputtering. The model shows that the existing poisoning mechanisms, i.e., chemisorption, direct reactive ion implantation and knock on implantation, are insufficient to describe the poisoning behavior of the rotating target. A better description of the process is only possible by including the deposition of sputtered material on the target.

36 MATERIALS SCIENCE↗

Experimental verification of a real-time compensation functionality for dose changes due to target motion in scanned particle therapy

Purpose: Implementation and experimental assessment of a real-time dose compensation system for beam tracking in scanned carbon beam therapy of intrafractionally moving targets. Methods: A real-time dose compensation functionality has been developed and implemented at the experimental branch of the beam tracking system at GSI Helmholtzzentrum fuer Schwerionenforschung (GSI). Treatment plans for different target geometries have been optimized. They have been delivered using scanned carbon ions with beam tracking (BT) and real-time dose compensation combined with beam tracking (RDBT), respectively. Target motion was introduced by a rotating table. Dose distributions were assessed by ionization chamber measurements and dose reconstructions. These distributions have been compared to stationary delivery for BT as well as RDBT. Additionally simulations have been performed to investigate the dependence of delivered dose distributions on varying motion starting phases for BT and RDBT, respectively. Results: Average measured dose differences between static delivery and motion influenced delivery could be reduced from 27-68 mGy when BT was used to 12-37 mGy when RDBT was used. Nominal dose was 1000 mGy. Simulated dose deliveries showed improvements in dose delivery and robustness against varying starting motion phases when RDBT was used. Conclusions: A real-time dose compensation functionality extending the existing beam tracking functionality has been implemented and verified by measurements. Measurements and simulated dose deliveries show that real-time dose compensation can substantially improve delivered dose distributions for large rotational target motion compared to beam tracking alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗

Status and performance of the GlueX DIRC

In support of the future physics program at Ce+BAF, we propose a prototype positron target. The prototype target consists of a tungsten disk mounted on a water-cooled copper support structure to enhance heat removal. The primary goals of this work are to benchmark CFD simulations, ensure vacuum integrity at the 10^-6 Pa level, achieve stable target rotation up to 10 Hz, and implement efficient water-based cooling for sustained high-power operation. To manage the thermal load, the target is designed to rotate, allowing the deposited heat to spread over a larger region, and thereby reducing localized thermal stress while maintaining the maximum temperature below 1000 K. To experimentally evaluate the thermal performance and structural stability of the target, we plan to conduct high-power laser heating tests at Laser Lab 5, LERF Building, JLab. These tests will serve as a stepping-stone for the positron production target at CEBAF.

Stevens, J.R. [College of William and Mary, Willia↗

The Pseudosynchronization of Binary Stars Undergoing Strong Tidal Interactions

Eccentric binaries known as heartbeat stars experience strong dynamical tides as the stars pass through periastron, providing a laboratory to study tidal interactions. We measure the rotation periods of 24 heartbeat systems, using the Kepler light curves to identify rotation peaks in the Fourier transform. Where possible, we compare the rotation period to the pseudosynchronization period derived by Hut. Few of our heartbeat stars are pseudosynchronized with the orbital period. For four systems, we were able to identify two sets of rotation peaks, which we interpret as the rotation from both stars in the binary. Most stars in our sample have rotation rates larger than the pseudosynchronization period while a single target rotates much faster than this rate. The majority of the systems have a rotation period that is approximately (3/2) times the pseudosynchronization period, suggesting that other physical mechanisms strongly influence the star’s evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-B-204-00: Implanted Markers for Radiation Therapy and TG 199 Update

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

TH-B-204-01: Real-Time Tracking with Implanted Markers

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

TH-B-204-02: Application of Implanted Markers in Proton Therapy

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗