At least 19 records

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Storage and Visualization Solutions for Real Time Simulations and Experiments

There are multiple challenges in performing real time simulations and real time experiments. Data storage and visualization are challenges that could be solved easily and when solved provide rich and valuable insights into the experiments. In this presentation, we will talk about the National Renewable Energy Laboratory solutions to tackle these issues while running real time experiments and simulations. The NREL team has made these open-source for the community to utilize with real time simulations and experiments.

data storage↗

Fuel Cell Stack Model for Real-Time Simulation of Grid-Connected Applications

Fuel cell stacks coupled with electrolyzers and hydrogen storage sites can be a promising category of distributed energy resources for both grid-connected and stand-alone power systems. However, because of high costs, at-scale hardware testing of fuel cell stacks for grid-connected applications is not economically viable at present. A model-based system that can accurately captures the steady-state and dynamic response of fuel cell stacks over long time periods (hours), is needed. This paper demonstrate a real-time electromagnetic transient model of a megawatt-scale, grid-connected proton exchange membrane fuel cell stack, coupled with a mass-based hydrogen storage system. This model can emulate the electrical steady-state and dynamic response of grid-connected fuel cell stacks. We validate the model using the response of commercial hardware fuel cell stacks and analytical models in the literature - using a digital real-time simulator (RSCAD). The proposed real-time model is then used to simulate cases spanning different time horizons and to design controller-hardware-in-the-loop experiments to evaluate controllers for hydrogen stations.

activation potential↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY↗

CFD-trained ANN Model for Approximating Near-occupant Condition in Real-time Simulations

The main drawback of Computational Fluid Dynamics (CFD) simulations has been the time and resource consuming nature which is not suitable for real-time applications. In this work, we first generated numerous CFD models of a given indoor space to obtain airspeed, temperature, and mean radiant temperature near an occupant as training data. Several artificial neural networks (ANN) models were trained using this CFD simulated data to approximate near real-time environmental conditions for a given occupant. This trained ANN model approach is a part of a real-time simulation of building operations using a combination of software and real hardware (HVAC equipment) approaches. The preliminary results suggest that the CFD- generated training data and the trained ANN model can accurately approximate such conditions in a real-time application, a method that has great potential in building simulation and building digital twin areas of research.

Zhang, Yun↗

A generic method for interfacing IEDs using low voltage interfaces to real-time simulators with hardware in the loop

This study presents an interface method (IM) to interconnect real-time simulators (RTSs) without amplifiers for different intelligent electronic devices (IEDs), such as protective relays, smart meters, and other devices. It is a significant topic for the power systems protection community because there are many protection devices with different requirements. These protection devices have pinouts that measure bus voltages/currents and breaker pole states and generate trip/close pulse signals. Most of the emulation test beds with RTSs and HIL need amplifiers to connect IEDs from different product manufacturers because the low-voltage interface levels are not available in some instruction manuals. Additionally, commercial amplifiers have cutoff frequency limitations and have an excessive cost when several IEDs are wired onto test beds. Then, the validation of protection and control systems with RTSs and IEDs in the loop from different vendors without amplifiers results in an unfeasible alternative. In this paper, the IM was based on using an interface box, power source, and RTS to identify IED inputs/outputs. Here, the sequence to recognize IED pinouts and calculate the current/voltage scaling factors is described. The IM was validated satisfactorily with RTS and a protection device (with unknown pinouts) in the loop.

42 ENGINEERING↗

Architecture for Quantum-in-the Loop Real-Time Simulations for Designing Resilient Smart Grids

With the power grid growing more complex every day with the inclusion of new sensors and regulatory approvals that enable end-users and small local developers to participate in the grid, it is becoming challenging for conventional smart grid simulation, emulation, and testing technologies to keep up. In this work, we propose that quantum-encoded real-time simulations can be helpful under the new paradigm and operational circumstances to solve optimization problems for power grids. By leveraging the principles of quantum mechanics, the proposed quantum-in-loop (QIL) framework will enable better and faster optimization solutions based on real-world, real-time data streams, facilitating the real-time planning and operations of electrical grids that rely on millions of distributed sensors and controllers. Furthermore, QIL will allow researchers and engineers to assist utilities in designing, developing, and de-risking algorithms to optimize power grid operation and resilience by considering inputs from millions of grid-connected devices. QIL framework is being developed to have a self-limiting triage mechanism, which will help engineers and practitioners identify fundamental physical limits on quantum processors, revealing what quantum algorithms can and cannot do in utility-specific use cases and must continue to count on classical high-performance computing infrastructure.

digital real-time simulation↗

An Integrated High-performance Computing and Digital Real-time Simulation Testbed to Benchmark Closed-loop Load Shedding Algorithms in Power Systems

An integrated testbed using digital real-time simulator (DRTS) and a high-performance computing (HPC) cluster is presented here to compare speed and performance of computational schemes to mitigate time-critical issues in electric power systems. The first approach in this testbed validation is taken by running a set of closed-loop load shedding algorithms to compare and contrast two paradigms of arresting cascading failure propagation. Two algorithms involve solving DC and AC power flow model-based optimization problems to compute load shedding at different buses, while a model-based stochastic search using parallel computing provides a viable alternative. The algorithms are implemented in the DRTS-HPC testbed for the IEEE 14-bus benchmark transmission system. As a proof of the concept, simulation results are presented for implementation of closed-loop load-shedding algorithms for cascading failures in the DRTS-HPC testbed

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal modifications of mesons and energy-energy correlators from real-time simulations of a 𝑈⁡(1) lattice gauge theory

We investigate thermal properties of a 𝑈⁡(1) lattice gauge theory in 1 + 1 dimensions through real-time simulations. We extract the spectral functions directly coupling to the pseudoscalar and scalar mesons, demonstrating the thermal modifications of these states with increasing temperatures. Introducing the notion of energy-flow operators, we quantify the temporal buildup of correlations in the energy flows across the lattice. We demonstrate that energy-energy correlators fail to factorize to products of energy flows, both in the vacuum and at nonzero temperature, indicating the presence of nontrivial correlations in the quantum states. Our results constitute a first real-time ab initio study of bound-state thermal broadening and finite temperature energy-flow correlations in a gauge theory, providing a benchmark for future studies of hadronic matter under extreme conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time simulation of asymmetry generation in fermion-bubble collisions

Motivated by the out-of-equilibrium dynamics during an early-Universe first-order phase transition, we perform real-time simulations of fermion-bubble scattering in 1 + 1 dimensions. This nonequilibrium process can generate a charge-conjugation C asymmetry outside the bubble wall, induced by the complex fermion mass profile. The resulting C asymmetry is the 1 + 1 -dimensional analog of the C P asymmetry in 3 + 1 dimensions, a key ingredient in baryon asymmetry generation at the electroweak scale. Using tensor network methods, we track the real-time evolution of the C asymmetry in the charge density as the fermion interacts with the bubble wall, a regime inaccessible to analytic calculations. We further introduce two observables to quantify the asymmetry in the asymptotic region where reflected particles are well separated from the scattering point: one based on the net charge outside the bubble wall, and the other on the spatial displacement between the reflected particle and antiparticle wave packets. Our study represents a first step toward nonperturbative, real-time computations of C P asymmetry in 3 + 1 dimensions for electroweak baryogenesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Integration of Multiple Real-time Simulation Platforms with AIO for Scalability

This paper introduces a practical and scalable approach to extend interoperability of Controller Hardware in the Loop (CHIL) validations for large scale microgrids, networked microgrids, and power electronics-based feeders. The work focuses on integrating multiple real-time simulators using Analog Input/Output (AIO) interface techniques in heterogeneous CHIL environment. It explores interfacing methods, highlighting key challenges related to dynamic accuracy and maintaining bidirectional power balance. A comparative evaluation of the Ideal Transformer Method is presented, assessing its effectiveness in multi-CHIL integration scenarios. The feasibility of this setup is demonstrated through a real-time use case involving multiple Typhoon HIL and Opal-RT platforms, showcasing its applicability for distributed system studies.

Khalid, Mohammad [ORNL] (ORCID:0000000179208805)↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗