Engineering PapersSearch

SEARCH · Engineering Papers

Results for “pulse position modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Intrinsic optical bistability of photon avalanching nanocrystals

Optically bistable materials respond to a single input with two possible optical outputs, contingent on excitation history. Such materials would be ideal for optical switching and memory, but the limited understanding of intrinsic optical bistability (IOB) prevents the development of nanoscale IOB materials suitable for devices. Here we demonstrate IOB in Nd 3+ -doped KPb 2 Cl 5 avalanching nanoparticles, which switch with high contrast between luminescent and non-luminescent states, with hysteresis characteristic of bistability. Here we elucidate a non-thermal mechanism in which IOB originates from suppressed non-radiative relaxation in Nd 3+ ions and from the positive feedback of photon avalanching, resulting in extreme, >200th-order optical nonlinearities. The modulation of laser pulsing tunes the hysteresis widths, and dual-laser excitation enables transistor-like optical switching. This control over nanoscale IOB establishes avalanching nanoparticles for photonic devices in which light is used to manipulate light.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Overview of the ICRF heating system in SPARC

Ion Cyclotron Range of Frequencies (ICRF) heating is a critical system for the SPARC mission of demonstrating net positive fusion gain. In the first campaign, 20 MW of installed power at 120 MHz will be supplied to 10 four-strap antennas, arranged in poloidal pairs. The matching network is designed to accommodate for a range of loading conditions and a fast controller adjusts the matching during a pulse with frequency modulation of ±1 MHz. For the main L-mode scenario of the first experimental campaign, the power coupling and absorption is analysed in this work. Several feeding schemes are compared and limits on the amount of the total coupled power are evaluated. Coupling of the full 20 MW power is possible well within the limit of the peak electric field in the transmission line of 15 kV/cm. The 3 He minority and 2 nd harmonic T heating scheme is validated in full-wave modelling to be efficient for heating plasma in the SPARC L-mode Q>1 scenario, with dominant ion heating and efficient single-pass absorption. A range of ICRF wave parameters and minority concentration would be suitable for operation and allow tailoring the heating properties for plasma conditions and experimental objectives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Elucidating Quintet-State Dynamics in Singlet Fission Oligomers and Polymers with Tetracene Pendants

To unlock the potential of molecular engineering for practical quantum sensing and computing, it is essential to create and control pure magnetic states in molecular systems. Singlet fission (SF) in organic materials offers a promising approach by generating pairs of triplet excited states from photoexcited singlets. Here, in this work, we investigate SF in a polymer with strategically positioned tetracene pendant groups along a polynorbornene backbone and its oligomeric counterparts, facilitating intrapolymer through-space coupling. Using continuous-wave and pulsed time-resolved electron paramagnetic resonance (EPR) spectroscopy, we elucidate the spin dynamics and identify key intermediates, including the quintet state, that emerge during SF. Our findings reveal that exciton translational motion along the pendant groups enhances the dissociation of triplet pairs, with oligomer length playing a critical role in modulating spin state interconversion and exciton transport. Our results provide key insights into the SF mechanism in polymeric materials and highlight the role of oligomer length in modulating spin state interconversion and exciton transport. This work advances our understanding of SF in polymers, paving the way for their application in quantum information science and energy conversion technologies.

Bindra, Jasleen K. [Argonne National Laboratory (A

Efficient generation and extreme compression of multidimensional solitary states in molecular gas-filled hollow-core fibers driven by picosecond Yb lasers

We present an in-depth study on the impact of spatiotemporal Raman enhancement in molecular gas-filled hollow-core fibers (HCFs), demonstrating the efficient generation and post-compression of multidimensional solitary states (MDSS). Through different experimental scenarios—employing large-core HCFs filled with molecular gases (N 2 and N 2 O) and driven by high energy, sub-picosecond and picosecond Fourier transform-limited ytterbium laser pulses—this work leverages multimode propagation and enhanced spatiotemporal interactions to achieve significant spectral broadening and asymmetric redshift, contrasting sharply with self-phase modulation. Our findings reveal that, beyond the regime of maximum nonadiabatic molecular alignment, spatiotemporal nonlinear enhancement primarily governs spectral broadening for input pulse durations up to 1 ps. The process shows limited sensitivity to input pulse duration and the two investigated molecular gases (N 2 and N 2 O), with only subtle differences in broadening arising from their distinct Raman spectroscopic properties. Furthermore, post-compression of MDSS was achieved in various cases. Notably, using 7 mJ, 1 ps laser pulses, we generated 22 fs pulses with a 47% energy conversion efficiency of the input pulse energy. These results position MDSS as a powerful platform for generating high-energy, ultrashort pulses with tunable wavelengths, offering a robust solution for applications such as high harmonic generation.

47 OTHER INSTRUMENTATION

Nonlinear regenerative amplification using tunable intracavity cascaded quadratic nonlinearities

Conventional nonlinear regenerative amplification utilizes Kerr (i.e., self-focusing) nonlinearity to broaden the spectrum via self-phase modulation during the direct amplification of ultrashort pulses, which helps overcome spectral gain narrowing for high-energy, ultrashort-pulse generation. We introduce cascaded quadratic nonlinearities from a type-I second-harmonic generation crystal, which can be tuned in both magnitude and sign via the phase-mismatching condition, inside a regenerative amplifier to enable nonlinearity-tunable regenerative amplification. We demonstrate, both experimentally and numerically, a nonlinear Yb:YAG thin-disk regenerative amplifier with either positive or negative net nonlinearity that delivers 1-kHz, >0.4-mJ pulses as short as ∼200 fs and high-quality beams free of self-focusing. The laser’s average power can be scaled to >100 W when seeded and operated at a much higher repetition rate to benefit various applications.

47 OTHER INSTRUMENTATION

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)

Late Life Supplementation of 25‐Hydroxycholesterol Reduces Aortic Stiffness and Cellular Senescence in Mice

ABSTRACT Stiffening of the aorta is a key antecedent to cardiovascular diseases (CVD) with aging. Age‐related aortic stiffening is driven, in part, by cellular senescence—a hallmark of aging defined primarily by irreversible cell cycle arrest. In this study, we assessed the efficacy of 25‐hydroxycholesterol (25HC), an endogenous cholesterol metabolite, as a naturally occurring senolytic to reverse vascular cell senescence and reduce aortic stiffness in old mice. Old (22–26 months) p16‐3MR mice, a transgenic model allowing for genetic clearance of p16‐positive senescent cells with ganciclovir (GCV), were administered vehicle, 25HC, or GCV to compare the efficacy of the experimental 25HC senolytic versus genetic clearance of senescent cells. We found that short‐term (5d) treatment with 25HC reduced aortic stiffness in vivo, assessed via aortic pulse wave velocity (p = 0.002) to a similar extent as GCV. Ex vivo 25HC exposure of aorta rings from the old p16‐3MR GCV‐treated mice did not further reduce elastic modulus (measure of intrinsic mechanical stiffness), demonstrating that 25HC elicited its beneficial effects on aortic stiffness, in part, through the suppression of excess senescent cells. Improvements in aortic stiffness with 25HC were accompanied by favorable remodeling of structural components of the vascular wall (e.g., lower collagen‐1 abundance and higher α‐elastin content) to a similar extent as GCV. Moreover, 25HC suppressed its putative molecular target CRYAB, modulated CRYAB‐regulated senescent cell anti‐apoptotic pathways, and reduced markers of cellular senescence. The findings from this study identify 25HC as a potential therapy to target vascular cell senescence and reduce age‐related aortic stiffness.

Cell Biology

Sub-Nanometer Nanoclusters of Copper Atop Single-Atom Copper Moieties toward Electrochemical CO 2 Hydrogenation to Methane

The electrochemical CO 2 reduction (eCO 2 R) offers a compelling route for converting CO 2 into value-added fuels and chemicals. Among CO 2 -derived products, methane (CH 4 ) occupies a distinct position, serving both as a key intermediate for emerging cascade electro-oxidation to oxygenates and as a strategically important extraterrestrial fuel that can be generated in situ from off-planet CO 2 resources. Although Cu-based catalysts capable of selectively producing CH 4 have been reported, they seldom sustain high selectivity at practically relevant current densities. Here, we created a single-step co-pyrolysis strategy toward generating and anchoring Cu sub-nanometer clusters (Cu SNC ) atop Cu-N x single-atom (SA) motifs embedded within N-doped carbon (NC), with controllable nanostructures through tuning of the synthesis parameters. Complementary spectroscopic analyses and density functional theory (DFT) calculations help reveal a structure−activity correlation that could guide the catalyst design. The Cu SNC @NC sample synthesized at 550 °C pyrolysis temperature (best described and modeled as Cu 3 -CuN 4 domains) represents the most effective combination of cluster size, metal-nitrogen coordination, and adsorption energetics needed to selectively promote CH 4 generation versus other eCO 2 R products. Incorporating pulsed electrolysis and hydrophobicity-modulated transport tuning at the triple-phase boundary (TPB) further enhanced CH 4 production achieving a partial CH 4 current density of ∼321 mA cm −2 , 53% Faradaic efficiency (FECH 4 ), and less than 4% combined FE for other eCO 2 R products, simplifying downstream CH 4 purification or upgrading. This work establishes generalizable principles for controlling Cu cluster atomicity and metal−nitrogen coordination, both of which are recognized determinants of CH 4 -efficient eCO 2 R.

CH4 production

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN