Engineering PapersSearch

SEARCH · Engineering Papers

Results for “pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Studies of the influence of heat pipe model and coupling strategy in heat pipe microreactor simulations using Sockeye

This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.

Direwolf

High Performance Heat Pipe Power Transient Testing at SPHERE Facility

Microreactors are being researched, designed, and built at Idaho National Laboratory (INL). Microreactors are small reactors defined at less than 20MW of power. These reactor concepts are also being looked at throughout industry for various applications. An important aspect of these reactor designs is economic feasibility i.e. lower overnight capital cost. The driving factors for implementing microreactors are quick setup and takedown, minimal operators, and the ability to manufacture them readily and to fit in mid-sized containers for transport. A specific area of research to aid in successful integration of these factors within the designs is passive heat removal of the core’s thermal power. Interest in heat pipes to achieve this passive heat removal has been shown across multiple industry partners. Because of this interest, INL has developed a test facility to facilitate experimental tests for sodium filled heat pipes. INL has developed the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility to run experiments on high performance, sodium filled heat pipes. As mentioned above, heat pipes are passive heat transfer devices. Radially, heat pipes are broken up into an outer wall, a small annular gap, a wick structure, and a centerline gap. They function by utilizing latent heat transfer. Heat pipes are traditionally separated into three regions, an evaporator (heat input), an adiabatic region, and finally a condenser region (heat removal). As heat is being applied to the evaporator, the working fluid undergoes a phase change to a vapor. This phase change causes a differential pressure across the axial length of the pipe driving flow down the center gap of the heat pipe. The vapor flows down past the adiabatic region to the condenser where the heat is removed. This heat removal forces the working fluid to phase change back to a liquid. The wick structure is then utilized to drive the flow back towards the evaporator by capillary forces. This backflow is aided by the annular gap. Because this heat transfer mechanism functions with latent heat transfer, the heat pipe is close to isothermal down the axial length. Heat pipes can operate under a wide range of working fluids. Considerations for these working fluids are primarily driven by operating temperatures amongst other important factors based around overall performance. Sodium filled heat pipes operate from 450°C up to 900°C. This temperature range works well for the current microreactor designs. In conjunction with this experimental capability, INL has developed a modeling software to simulate heat pipe physics within reactor cores. This modeling software is called Sockeye and functions under the established INL Multiphysics Object Oriented Simulation Environment (MOOSE). SPHERE also supports Sockeye development by providing the modeling team with experimental data on an array of setups and operating parameters to support validation efforts. A power transient experiment was performed utilizing the SPHERE facility to continue to aid with Sockeye development. The testing followed a proposed test plan to ramp up and down the temperature of the heat pipe. Sockeye models steady state heat pipe operation with high accuracy, the data provided by the power transient testing aims to assist with the validation efforts and further enhance transient modeling capability of the tool [2].

22 GENERAL STUDIES OF NUCLEAR REACTORS

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.

97 - MATHEMATICS AND COMPUTING

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE

Integrating Crack Detection and Pipe Shape Optimization for Enhanced Sewage System Durability

Crack detection in underground reinforced concrete pipes has been essential in determining the state of stormwater infrastructure. Detection models have been implemented for detecting cracks and other defects in pipes using CCTV footage for stormwater drainage systems. In addition, Finite element models have been used to determine optimum shapes and pipe thickness for different boundary conditions such as header pipes in power plants. The concept of shape optimization emerges as a crucial factor in power plant design and operation, with the potential to maximize performance while minimizing the use of materials. Shape optimization not only enhances efficiency but also contributes to reducing the environmental footprint. This paper discusses the integration of both topics by using the cracks detected in underground pipes as boundary conditions for shape optimization of the pipes. A machine learning model has been developed which uses limited data for training and outlines the location of detected cracks. A shape optimization methodology is proposed in which ANSYS modules are used to analyze fluid flow and then optimize the shape of the pipe. The crack detection model developed has been applied to a crack detected in lab setting and machine learning model used has an accuracy of 98% using a random forest algorithm.

20 FOSSIL-FUELED POWER PLANTS

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Recent Developments and Findings of Heat Pipe Experiments for Microreactor Applications

Microreactor technologies are required to provide reliable carbon-free power generation in remote applications. The heat pipe–cooled microreactor concept, in particular, offers notable advantages due to the passive operation of heat pipes, enabling increased reliability and simplicity in a more compact form factor. There is a significant need for experimental work to aid and expedite the deployment of heat pipe microreactors due to their unique technological characteristics. Thus, there has been increased interest in heat pipe experiments by numerous institutions in order to support these efforts. Finally, the present work is a comprehensive review of recent heat pipe experiments from six major institutions, describing their designs, instruments, methods, and results. In addition, this paper also presents a background on heat pipe experiments along with discussions on instrumentation, accident scenarios, wick enhancement, and proposed future directions.

22 GENERAL STUDIES OF NUCLEAR REACTORS

High-Fidelity Multiphysics Modeling of a Heat Pipe Microreactor Using BlueCrab

Researchers who are actively developing nuclear microreactors are planning to employ innovative designs and features using traditional commercial modeling tools that may be inadequate for their design and licensing activities. The codes developed under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) program provide flexibility in terms of geometry modeling and multiphysics coupling and are particularly well suited for modeling novel microreactor concepts. To test the maturity of these codes, this paper introduces a conceptual heat pipe microreactor (HP-MR) designed to gather various technologies of interest to microreactor developers such as control drums, heat pipes, and hydride moderators. Here, the objective of this effort is to demonstrate NEAMS tools capability to perform high-fidelity multiphysics simulations, using coupled neutronics (via the Griffin code), heat conduction (via the BISON code), heat pipe modeling (via the Sockeye code), and hydrogen redistribution in hydride metal moderator (via the SWIFT code). Codes are coupled in-memory through the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, which permits flexible multiphysics data transfer schemes. The analysis confirmed two key aspects of the HP-MR concept: (1) its ability to follow the power load requested from the heat pipe and (2) its ability to avoid heat pipe cascading failure unless designed with high power close to operating failure limits of its heat pipes. The developed computational model was distributed publicly on the Virtual Test Bed for training purposes to accelerate adoption by industry and to provide a high-fidelity multiphysics solution for benchmarking against other tools. Additional multiphysics analyses including other transients and coupled physics were identified as necessary future work, together with a focus on validating multiphysics behavior against experiments.

Microreactor

Non-invasive Pipe Pressure Monitoring for Safeguards

Our project explores a new solution to complement current safeguards toolbox by independently, and noninvasively, determining the pressure inside uranium hexafluoride (UF 6 )-carrying Gas Centrifuge Enrichment Plant (GCEP) pipes. Proof-of-principle, non-invasive pipe pressure monitoring tests were conducted through measurements of hoop and axial strain using an optical-interference dilatometry technique based on fiber Bragg gratings (FBGs) inscribed in the core of telecommunication-type 125 µm diameter optical fibers. The fibers were affixed to commercial stainless steel and aluminum tubes and pipes of the type expected to be found at GCEP’s, each measuring four inches in diameter. When the internal air pressure in the pipes changes their external diameter and length follow, and the pitch in the FBG shrinks and/or expands accordingly. In turn, these changes result in a shift of the light wavelength reflected by the FBGs. Several FBGs physically attached to the pipe, as well as control FBGs not attached, were interrogated during the process using state-of-the-art commercial interrogators that operate on swept-wavelength laser technology. Strains measured were contrasted against calculations based on the known elastic and mechanical properties of the pipes. Good agreement is found, and strategies are proposed for further improvement of the experimental resolution as well as future implementation of this novel approach for GCEP safeguards.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Study of the heat pipe vapor flow using the MOOSE application Sockeye and the CFD code Nek5000

Heat pipes are efficient heat transfer devices used in various applications, including nuclear microreactors. Heat pipe-cooled microreactors offer advantages in size and cost, which can significantly accelerate their deployment and adoption. Developing accurate models of heat pipes is crucial for a heat pipe-cooled microreactor design and operation. In this work a verification and validation of the heat pipe application Sockeye is presented. Results are compared against RANS simulations, performed with the code Nek5000, and the SPHERE experiment, conducted at INL.

42 ENGINEERING

Modeling heat pipe startup and noncondensable gases in Sockeye

For this work, a one-dimensional gas mixture flow model was developed and implemented in the heat pipe code Sockeye to model the effects of noncondensable gases. Additionally, a startup model based on the dusty gas model was implemented to model the transition from rarefied gas dynamics to continuum flow, which occurs during the frozen startup of high-temperature heat pipes. Multiple startup and noncondensable gas models were tested against experimental data for sodium heat pipes, showing excellent agreement. Additionally, the newly developed gas mixture model for modeling noncondensable gas is further tested with a theoretical case study with arbitrary heating configurations. Finally, several recommendations and conclusions are made from the studies in this work to guide future heat pipe modeling efforts.

97 - MATHEMATICS AND COMPUTING

Pipeline for Integrated Projects in Energy Systems (PIPES): A Tool for Integrated System Planning [Slides]

The Pipeline for Integrated Projects in Energy Systems (PIPES) is a comprehensive project, data, and workflow management tool designed for integrated modeling teams. PIPES facilitates the management of data requirements, tasks, and progress tracking, serving as a higher-level integration layer that works across various data and modeling software. This tool integrates models, data, and tools to perform large-scale, integrated analysis work at scale. PIPES is designed to streamline integrated modeling projects, enhance collaboration, and ensure the quality and efficiency of data management and workflow processes. This presentation introduces PIPES a multi-model tool for integrated system planning; it describes the underlying architecture, deep dives into common user workflows, and outlines the upcoming development roadmap beyond its current alpha state.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Modeling Heat Pipe Startup And Noncondensable Gases In Sockeye

A one-dimensional gas mixture flow model was developed and implemented in the heat pipe code Sockeye to model the effects of non-condensable gases. Additionally a startup model based on the dusty gas model was implemented to model the transition from rarefied gas dynamics to continuum flow, which occurs during the frozen startup of high-temperature heat pipes. Multiple startup models and non-condensable gas models were tested against experimental data for sodium heat pipes, showing excellent agreement. Additionally, the newly developed gas mixture model for modeling non-condensable gas is further tested with a theoretical case study with arbitrary heating configurations. Finally, several recommendations and conclusions are made from the studies in this work to guide future heat pipe modeling efforts.

97 - MATHEMATICS AND COMPUTING

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS