Experimental Modal Analysis Using Phase Quantities from Phase-Based Motion Processing and Motion Magnification

Phase-based motion processing and the associated Motion Magnification that it enables has become popular not only for the striking videos that it can produce of traditionally stiff structures visualized with very large deflections, but also for its ability to pull information out of the noise floor of images so that they can be processed with more traditional optical techniques such as digital image correlation or feature tracking. While the majority of papers in the literature have utilized the Phase-based Image Processing approach as a pre-processor for more quantitative analyses, the technique itself can be used directly to extract modal parameters from an image, noting that the extracted phases are proportional to displacements in the image. Therefore, once phases are extracted, they can be fit using traditional experimental modal analysis techniques. This produces a mode “shape” where the degrees of freedom are phases instead of physical motions. These phases can be scaled to produce on-image visualizations of the mode shapes, rather than operational shapes produced by bandpass filtering. Modal filtering techniques can also be used to visualize motions from an environment on an image using the modal phases as a basis for the expansion.

47 OTHER INSTRUMENTATION↗

To the Moon! Space Launch System Modal Testing with Video and Motion Magnification

MIT Lincoln Laboratory and NASA Marshall Space Flight Center have been collaborating on using video camera measurements and motion magnification for modal testing of large aerospace components for several years. This presentation will discuss results from the Space Launch System Integrated Modal Test (IMT) and Dynamic Rollout/Rollback Test (DRRT) in support of the Artemis I mission. During the IMT, the data collection focused on operational mode shapes. In addition, the cameras were repositioned mid-test to better understand the physics of a low-frequency torsion mode. The non-contact nature of video data capture allowed for the quick redeployment of the cameras while not causing any delay in test schedule, whereas traditional instrumentation would have required a pause in testing to attach the sensors to the test article. The motion magnification analysis was able to find the low-frequency operational mode shapes and help the test team better understand the physics of the torsion mode. Building upon the success of the IMT motion magnification work, a camera system was used during the DRRT to find operational mode shapes, if the physics of the low-frequency torsion mode remained with different boundary conditions, and relative deflection of the vehicle and ML tower during the roll. In this paper we will present operational mode shape results, discuss the physics of the torsion mode, and review experimental setup idiosyncrasies to help the community in designing video camera measurement systems.

optical↗

Motion Magnification to Visualize the Modes of Space Structures

Traditional structural testing involves using accelerometers and strain gages to measure the motion. While this traditional instrumentation suite has proven accurate, it is limited to capture data only in the discrete locations where the transducers are placed. Additionally, applying the instrumentation can be a difficult and labor intensive task. By using video cameras, the motion of the test article – such as a launch vehicle or launch vehicle payload – can be easily captured at any location in the field of view and easily visualized using a post-processing technique called Motion Magnification. It is also much easier to place video cameras to measure motion rather than having to place contact sensors, especially when placement locations can be limited on final flight hardware. Recently, a team of MIT Lincoln Laboratory (MITLL) and NASA Marshall Space Flight Center (MSFC) have been collaborating to use Motion Magnification to measure the dynamics of large space structures. This presentation will detail some of the results of this collaboration.

Eric Colby Stewart↗

Motion Magnification to Visualize the Modes of Space Structures

Traditional structural testing involves using accelerometers and strain gages to measure the motion. While this traditional instrumentation suite has proven accurate, it is limited to capture data only in the discrete locations where the transducers are placed. Additionally, applying the instrumentation can be a difficult and labor intensive task. By using video cameras, the motion of the test article – such as a launch vehicle or launch vehicle payload – can be easily captured at any location in the field of view and easily visualized using a post-processing technique called Motion Magnification. It is also much easier to place video cameras to measure motion rather than having to place contact sensors, especially when placement locations can be limited on final flight hardware. Recently, a team of MIT Lincoln Laboratory (MITLL) and NASA Marshall Space Flight Center (MSFC) have been collaborating to use Motion Magnification to measure the dynamics of large space structures. This presentation will detail some of the results of this collaboration.

Eric Colby Stewart↗

Applications of Phase-Based Motion Processing

Image pyramids provide useful information in determining structural response at low cost using commercially available cameras. The current effort applies previous work on the complex steerable pyramid to analyze and identify imperceptible linear motions in video. Instead of implicitly computing motion spectra through phase analysis of the complex steerable pyramid and magnifying the associated motions, instead present a visual technique and the necessary software to display the phase changes of high frequency signals within video. The present technique quickly identifies regions of largest motion within a video with a single phase visualization and without the artifacts of motion magnification, but requires use of the computationally intensive Fourier transform. While Riesz pyramids present an alternative to the computationally intensive complex steerable pyramid for motion magnification, the Riesz formulation contains significant noise, and motion magnification still presents large amounts of data that cannot be quickly assessed by the human eye. Thus, user-friendly software is presented for quickly identifying structural response through optical flow and phase visualization in both Python and MATLAB.

Branch, Nicholas A.↗

Nonlinear dynamic phenomena in the space shuttle thermal protection system

The development of an analysis for examining the nonlinear dynamic phenomena arising in the space shuttle orbiter tile/pad thermal protection system is presented. The tile/pad system consists of ceramic tiles bonded to the aluminum skin of the orbiter through a thin nylon felt pad. The pads are a soft nonlinear material which permits large strains and displays both hysteretic and nonlinear viscous damping. Application of the analysis to a square tile subjected to transverse sinusoidal motion of the orbiter skin is presented and the following nonlinear dynamic phenomena are considered: highly distorted wave forms, amplitude-dependent resonant frequencies which initially decrease and then increase with increasing amplitude of motion, magnification of substrate motion which is higher than would be expected in a similarly highly damped linear system, and classical parametric resonance instability.

Housner, J. M.↗

Detecting Flow-Induced Vibration in Bellows

The NESC performed testing to determine if high-speed video techniques can be used to predict the onset of flow-induced vibrations (FIV) in bellows. A comprehensive test matrix was established to determine if Motion Magnification (MM) and Digital Image Correlation (DIC) can be used to determine the onset of FIV in straight and gimbaled bellows. Several of the tests were intended to determine if MM and DIC can establish the resonant frequencies of the bellows with no a priori knowledge. The results of the MM and DIC were compared with data from strain gages and microphones. Although the testing was limited to one single-ply unshielded bellows, this effort provided the proof-of-concept that MM and DIC are feasible methods for determining the onset of FIV in bellows.

Flow-induced vibration↗

Eulerian frequency analysis of structural vibrations from high-speed video

An approach for the analysis of the frequency content of structural vibrations from high-speed video recordings is proposed. The techniques and tools proposed rely on an Eulerian approach, that is, using the time history of pixels independently to analyse structural motion, as opposed to Lagrangian approaches, where the motion of the structure is tracked in time. The starting point is an existing Eulerian motion magnification method, which consists in decomposing the video frames into a set of spatial scales through a so-called Laplacian pyramid [1]. Each scale — or level — can be amplified independently to reconstruct a magnified motion of the observed structure. The approach proposed here provides two analysis tools or pre-amplification steps. The first tool provides a representation of the global frequency content of a video per pyramid level. This may be further enhanced by applying an angular filter in the spatial frequency domain to each frame of the video before the Laplacian pyramid decomposition, which allows for the identification of the frequency content of the structural vibrations in a particular direction of space. This proposed tool complements the existing Eulerian magnification method by amplifying selectively the levels containing relevant motion information with respect to their frequency content. This magnifies the displacement while limiting the noise contribution. The second tool is a holographic representation of the frequency content of a vibrating structure, yielding a map of the predominant frequency components across the structure. In contrast to the global frequency content representation of the video, this tool provides a local analysis of the periodic gray scale intensity changes of the frame in order to identify the vibrating parts of the structure and their main frequencies. Validation cases are provided and the advantages and limits of the approaches are discussed. The first validation case consists of the frequency content retrieval of the tip of a shaker, excited at selected fixed frequencies. The goal of this setup is to retrieve the frequencies at which the tip is excited. The second validation case consists of two thin metal beams connected to a randomly excited bar. It is shown that the holographic representation visually highlights the predominant frequency content of each pixel and locates the global frequencies of the motion, thus retrieving the natural frequencies for each beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A magnifying scratch-gage force transducer

Single-component scratch-gage transducer incorporates a unique motion magnification scheme to increase the magnitude of the load measuring scratch approximately 15 times over that of conventional models. It is small, load carrying and high in natural frequency.

Scott, C. E.↗

A laboratory measurement of CCD photometric and dimensional stability

The sun exhibits periodic and quasi-periodic variability in its total luminosity, which provides information about its internal structure and dynamics. Variability ranges from a few minutes to many-year time scales, with amplitudes as small as a few ppm in the milliHz band. Extension of this analysis to a large sample of outer stars would be interesting: a panoramic detector such as a CCD could record many stars at once. To meet this objective, a ppm time-series differential precision is required. Laboratory CCD photometric measurements presented here are promising for such an instrument. Normalizing the response from a portion of the CCD area removes most of the individual-frame variability. When a trend attributed to a thermal transient in the CCD dewar is removed, the individual-frame photometric precision is about 0.0001, limited by photoelectron counting statistics. The time-series power spectrum is flat within the desired frequency domain. Analysis of the dimensional stability of the CCD within the same data set indicates better than ppm performance, when first-order bulk motion and magnification changes are removed.

Buffington, Andrew↗

Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.