Engineering PapersโŒ• Search

NASA NTRS ยท 20220004162

Detecting Flow-Induced Vibration in Bellows

Abstract

The NESC performed testing to determine if high-speed video techniques can be used to predict the onset of flow-induced vibrations (FIV) in bellows. A comprehensive test matrix was established to determine if Motion Magnification (MM) and Digital Image Correlation (DIC) can be used to determine the onset of FIV in straight and gimbaled bellows. Several of the tests were intended to determine if MM and DIC can establish the resonant frequencies of the bellows with no a priori knowledge. The results of the MM and DIC were compared with data from strain gages and microphones. Although the testing was limited to one single-ply unshielded bellows, this effort provided the proof-of-concept that MM and DIC are feasible methods for determining the onset of FIV in bellows.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel J Dorney. 2022-03-08. Detecting Flow-Induced Vibration in Bellows. https://ntrs.nasa.gov/citations/20220004162

Cite the original work for its findings. Save a collection to share your selection of sources.