Engineering PapersSearch

SEARCH · Engineering Papers

Results for “model-predictive HVAC control (MPC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando

Enhanced matter power spectrum from axion kination after Big Bang nucleosynthesis

Despite stringent constraints from Big Bang Nucleosynthesis (BBN) and cosmic microwave background (CMB) observations, it is still possible for well-motivated particle physics models to substantially alter the cosmic expansion history between BBN and recombination. In this work we consider two different axion models that can realize a period of first matter domination, then kination, in this epoch. We perform fits to both primordial element abundances as well as CMB data and determine that up to a decade of late axion domination is allowed by these probes of the early universe. We establish the implications of late axion domination for the matter power spectrum on the scales 1/Mpc ≲ k ≲ 10 3 /Mpc. Our 'log' model predicts a relatively modest bump-like feature together with a small suppression relative to the standard ΛCDM predictions on either side of the enhancement. Our 'two-field' model predicts a larger, plateau-like feature that realizes enhancements to the matter power spectrum of up to two orders of magnitude. These features have interesting implications for structure formation at the forefront of current detection capabilities.

79 ASTRONOMY AND ASTROPHYSICS

Realization of two-dimensional discrete time crystals with anisotropic Heisenberg coupling

A discrete time crystal (DTC) is an out-of-equilibrium phase of matter that spontaneously breaks discrete time-translation symmetry. Previous studies have been limited to a set of models with Ising-like couplings - and mostly only in one dimension - thus precluding our understanding of the existence (or not) of DTCs in models with more realistic interactions. In this work, by combining the latest generation of IBM quantum processors with state-of-the-art tensor network methods, we demonstrate the existence of a DTC in a two-dimensional system governed by anisotropic Heisenberg interactions. We uncover a rich phase diagram encompassing spin-glass, ergodic, and time-crystalline phases, and identify the interplay of initialization, interaction anisotropy, and driving protocols in stabilizing the DTC phase. By extending the study of Floquet matter beyond simplified models, we lay the groundwork for exploring how driven systems bridge the gap between quantum coherence and emergent non-equilibrium thermodynamics.

Phase transitions and critical phenomena

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine

GVIPS Prediction of Cyclic Ratchetting Behavior and Cycles with Interrupted Relaxation Periods of TIMETAL 21S at 650 °C

The predictive performance of a multimechanism GVIPS model with saturating hardening function is assessed against a set of high temperature cyclic experiments under both strain-control and stress-control at varying rates of loading as well as several complex interrupted cyclic responses. The material specimens were composed of the titanium alloy, TIMETAL 21S, and tested at 650 °C, see Lissenden et al., 2007. The model did a very good job of predicting the variety of tests, particularly given the fact that only monotonic loading tests (tensile, creep, relaxation) and a single fully reversed cycle was used for characterization. It was particularly interesting that the model was capable of reasonably capturing the rate of accumulated strain during ratchetting under tensile mean stress. Given complex interrupted cyclic response, the model was able to both qualitatively and even quantitatively predict reasonably well both the cyclic and associated relaxation periods (in all quadrants of the stress-strain space) thus confirming the validity of the chosen functional forms for both hardening and thermal recovery. The quantitative inaccuracy is associated with the fact that the material specimens tested by Lissenden et al., 2007 was significantly “softer” than those tested by Castelli in Saleeb et al., 1994 which were used for characterization of the GVIPS model parameters.

Viscoplaticity

Predicting microstructurally sensitive fatigue‐crack path in WE43 magnesium using high‐fidelity numerical modeling and three‐dimensional experimental characterization

Abstract Microstructurally small fatigue‐crack growth in polycrystalline materials is highly three‐dimensional due to sensitivity to local microstructural features (e.g., grains). One requirement for modeling microstructurally sensitive crack propagation is establishing the criteria that govern crack evolution, including crack deflection. Here, a high‐fidelity finite‐element modeling framework is used to assess the performance and validity of various crack‐growth criteria, including slip‐based metrics (e.g., fatigue‐indicator parameters), as potential criteria for predicting three‐dimensional crack paths in polycrystalline materials. The modeling framework represents cracks as geometrically explicit discontinuities and involves voxel‐based remeshing, mesh‐gradation control, and a crystal‐plasticity constitutive model. The predictions are compared to experimental measurements of WE43 magnesium samples subject to fatigue loading, for which three‐dimensional grain structures and fatigue‐crack surfaces were measured post‐mortem using near‐field high‐energy x‐ray diffraction microscopy and x‐ray computed tomography. Findings from this work are expected to improve the predictive capabilities of simulations involving microstructurally small fatigue‐crack growth in polycrystalline materials.

Engineering

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

The Significance of Water Vapor Isotopes in Improving Weather Prediction

Water vapor isotopes carry the integrated history of evaporation, condensation, mixing, and transport. Although previous studies have shown potential to improve forecasts under controlled conditions, real-world applications have been limited by systematic biases in both models and satellite retrievals arising from sparse measurements in the free troposphere. Here we assimilate mid‑tropospheric δD retrievals (peak sensitivity ~4.2 km) from the Infrared Atmospheric Sounding Interferometer into the Isotope‑incorporated Global Spectral Model and evaluate the added value beyond co‑assimilated temperature and specific humidity with identical spatial and temporal coverage. Assimilating δD improves 0–120 h forecasts of wind, temperature, specific humidity, and geopotential height, with the largest gains in the midlatitudes; heavy‑precipitation skill also increases for thresholds >3 mm per 6 h. Demonstrated in a coarse‑resolution configuration with limited observations, the results indicate that isotopic information strengthens transport tracking and hydrological constraints, motivating evaluation in operational high‑resolution forecasting systems.

Hydrology

Spacecraft Fire Safety Predictions using Verified Saffire Model

A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.

Fire Safety