Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methane concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coastal Forest Seawater Exposure Increases Stem Methane Concentration

Methane (CH 4 ) exchange between trees and the atmosphere has recently emerged as an important, but poorly quantified process regulating global climate. The sources (soil and/or tree) and mechanisms driving the increase of CH 4 in trees and degassing to the atmosphere are inadequately understood, particularly for coastal forests facing increased exposure to seawater. Here, we investigated the eco-physiological relationship between tree stem wood density, soil and stem oxygen saturation (an indicator of redox state), soil and stem CH 4 concentrations, soil and stem carbon dioxide (CO 2 ) concentrations, and soil salinity in five forests along the United States coastline. We aim to evaluate the mechanisms underlying greenhouse gas (GHG) increase in trees and the influence of seawater exposure on stem CH 4 accumulation. Seawater exposure corresponded with decreased tree survival and increased tree stem methane. Tree stem wood density was significantly correlated with increased stem CH4 in seawater exposed gymnosperms, indicating that dying gymnosperm trees may accumulate higher levels of CH 4 in association with seawater flooding. Further, we found that significant differences in seawater exposed and unexposed gymnosperm tree populations are associated with increased soil and stem CH 4 and CO 2 , indicating that seawater exposure significantly impacts soil and stem greenhouse gas abundance. Our results provide new insight into the potential mechanisms driving tree CH 4 accumulation within gymnosperm coastal forests.

54 ENVIRONMENTAL SCIENCES↗

Three-Dimensional Free Gas Flow Focuses Basin-Wide Microbial Methane to Concentrated Methane Hydrate Reservoirs in Geological System

Here, we present a systematic model that links the generation, migration, phase partitioning, and accumulation of methane into a closed loop as the sediment is deposited from the seafloor and buried through the base of hydrate stability zone (BHSZ). In our model, methane is generated by biodegradation of organic carbon in muds. Hydrate does not form and methane is not trapped until a coarse-grained layer is deposited, because the small pores prevent hydrate formation in muds. Instead, methane diffuses into sands/silts where methane solidifies into hydrate. As hydrate-bearing sands/silts pass through the BHSZ during sediment burial, methane hydrate dissociates, and releases free gas. The released and the newly generated free gas below the BHSZ concentrates into a vertical/dipping zone with low capillary entry pressure and high permeability and flows upward driven its buoyancy. When free gas reaches the hydrate stability zone (HSZ), capillary forces drive free gas to flow laterally, preferentially enter sands/silts, feed hydrate growth, and elevate hydrate saturation. With three-dimensional focused free gas flow, microbial methane that is generated from a much larger fetch area of the entire basin, both above and below the BHSZ, is concentrated into coarse-grained layers at structural closures for hydrate formation. Our model illustrates how geological evolution, microbial methane generation, and gas flow by buoyancy couple to generate concentrated hydrate deposits in geological system. These insights can be used to explore for high-concentration methane hydrate and are important for understanding the methane budget and carbon cycle under the seafloor.

58 GEOSCIENCES↗

High methane concentrations in tidal salt marsh soils: Where does the methane go?

Abstract Tidal salt marshes produce and emit CH 4 . Therefore, it is critical to understand the biogeochemical controls that regulate CH 4 spatial and temporal dynamics in wetlands. The prevailing paradigm assumes that acetoclastic methanogenesis is the dominant pathway for CH 4 production, and higher salinity concentrations inhibit CH 4 production in salt marshes. Recent evidence shows that CH 4 is produced within salt marshes via methylotrophic methanogenesis, a process not inhibited by sulfate reduction. To further explore this conundrum, we performed measurements of soil–atmosphere CH 4 and CO 2 fluxes coupled with depth profiles of soil CH 4 and CO 2 pore water gas concentrations, stable and radioisotopes, pore water chemistry, and microbial community composition to assess CH 4 production and fate within a temperate tidal salt marsh. We found unexpectedly high CH 4 concentrations up to 145,000 μmol mol −1 positively correlated with S 2− (salinity range: 6.6–14.5 ppt). Despite large CH 4 production within the soil, soil–atmosphere CH 4 fluxes were low but with higher emissions and extreme variability during plant senescence (84.3 ± 684.4 nmol m −2 s −1 ). CH 4 and CO 2 within the soil pore water were produced from young carbon, with most Δ 14 C‐CH 4 and Δ 14 C‐CO 2 values at or above modern. We found evidence that CH 4 within soils was produced by methylotrophic and hydrogenotrophic methanogenesis. Several pathways exist after CH 4 is produced, including diffusion into the atmosphere, CH 4 oxidation, and lateral export to adjacent tidal creeks; the latter being the most likely dominant flux. Our findings demonstrate that CH 4 production and fluxes are biogeochemically heterogeneous, with multiple processes and pathways that can co‐occur and vary in importance over the year. This study highlights the potential for high CH 4 production, the need to understand the underlying biogeochemical controls, and the challenges of evaluating CH 4 budgets and blue carbon in salt marshes.

54 ENVIRONMENTAL SCIENCES↗

Depth-resolved carbon dioxide and methane concentrations in 522 lakes, ponds, and reservoirs worldwide

Lakes, ponds, and reservoirs (hereafter: “lakes”) are important sources of the greenhouse gases carbon dioxide (CO 2 ) and methane (CH 4 ). Emissions of CO 2 and CH 4 from lakes are regulated in part by in-lake processes, including the production and storage of gases in the lower parts of the water column (bottom waters). However, while substantial efforts have been made to improve estimates of greenhouse gas emissions from lakes, limited data on gas concentrations along depth profiles have prevented the incorporation of bottom-water processes in global emission estimates. Here, we present GHG-depths: the largest existing dataset of depth-profile CO 2 and CH 4 measurements worldwide, including 522 lakes across 38 countries and all seven continents. These data include contributions from 45 research teams and 56 published studies, totaling 2558 discrete sampling events. As global change continues to alter biogeochemical cycling in lakes, these data can help improve mechanistic models to better predict greenhouse gas production and emission from lakes worldwide.

Rabaey, Joseph S. [University of Minnesota, Duluth↗

Spatial mapping of dissolved methane using an in situ sensor in Puget Sound

Release of methane, as gas bubbles or in the dissolved phase, from the seafloor has been observed in coastal waters (< 200 m) and deep ocean basins (> 1000 m). Methane dissolution within the water column affects the geochemistry of the surrounding water, leading to localized oxygen loss and potential escape to the atmosphere, particularly from shallower sites. Traditional methods for detecting and quantifying dissolved methane rely on collecting discrete water samples for ship- or land-based ex situ analysis and post processing. Here, we report on the use of a reduced response time, in situ methane sensor, the Sensor for Aqueous Gases in the Environment (SAGE), for detecting and quantifying dissolved methane concentrations in a wide range of seafloor environments. During a Fall 2022 research cruise on the R/V Thomas G. Thompson in Puget Sound, SAGE was integrated onto a towed conductivity/temperature/depth rosette and deep-sea camera system with live-stream 1 Hz telemetry and used to spatially map the concentration of methane approximately 1 m above the seafloor. The site had been previously identified as an active methane plume field characterized by gas bubbles, fluid venting, and a faulted seabed. The widespread background dissolved concentration of methane measured by SAGE was 83 nM, and a range of 78–670 nM was observed throughout the survey. The results highlight the capacity of SAGE to map the spatial and temporal variability of dissolved methane concentrations in situ and to identify and localize sites of variable methane emissions from the seafloor.

Padilla, Alexandra M. [Woods Hole Oceanographic In↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Fluid Dynamics-Based Modeling of Methane Flows Around Oil and Gas Equipment

Recent studies estimate that emissions from oil and gas production facilities contribute between 20 and 50% of the total methane ( CH 4 ) emitted in the US; therefore, quantifying and reducing these emissions are crucial for achieving climate goals. Methane quantification depends on both measuring methane concentrations and converting them to emissions through a modeling framework. Currently, simple atmospheric dispersion models are primarily used to quantify emissions and concentrations, but these estimates are highly uncertain when quantifying emissions from complex aerodynamic sources, such as oil and gas facilities. This investigation used a CFD modeling approach, which can account for aerodynamic complexity but has hitherto not been used to model methane concentrations downwind of a methane release of a known rate, and compared it against in situ measurements. High-time-resolution (1 Hz) methane concentration and meteorological data were measured during experiments conducted at the METEC on 21 March and 11 July 2024. The METEC site configuration, measured wind data, and controlled emission rates were used as input for the CONVERGE CFD model to model downwind CH 4 concentration. The modeling was carried out between 20 and 70 m, from two different points of release in two separate controlled-release experiments, one from a separator and another from a wellhead. In these experiments, we found that the CFD model could predict the CH 4 concentrations downwind of the release to a good degree. The model was evaluated on multiple metrics to assess its performance in estimating methane concentrations at typical fence line distances (∼30 m). These results help us to understand external flows and the ability of CFD models to predict downwind concentrations in aerodynamically complex environments.

03 NATURAL GAS↗

Combined Mixed Potential Electrochemical Sensors and Artificial Neural Networks for the Quantificationand Identification of Methane in Natural Gas Emissions Monitoring

Sensors capable of quantifying methane concentration and discriminating between possible sources are needed for natural gas leak detection where multiple spatially overlapping sources including wetlands and agriculture may be present. We report on the fabrication by an additive manufacturing process of a four electrode La 0.87 Sr 0.13 CrO 3 , Indium Tin Oxide (In 2 O 3 90 wt%, SnO 2 10 wt%), Au, Pt mixed potential electrochemical sensor using yttria-stabilized zirconia (YSZ) as a solid electrolyte to natural gas detection. Artificial neural networks (ANNs) are used to automatically decode the possible source and concentration of methane. The ANNs trained on sensor data are capable of correctly discriminating between three sources of methane emissions from simulated mixtures of emissions from cattle, wetlands, or natural gas with >98% accuracy. Quantification error for methane in mixtures of CH 4 in air, CH 4 + NH3 in air, and simulated natural gas is less than 1.5% ppm when a two-temperature dataset is employed.

03 NATURAL GAS↗

Insights into Designing an Efficient and Reliable Microwave-Assisted Methane Dehydroaromatization Process: Effect of Microwave Absorber on Catalyst Performance

Microwave-assisted methane dehydroaromatization has the potential to address challenges of traditional dehydroaromatization reactions. However, catalysts for microwave-enhanced reaction systems require effective coupling of fields with the catalyst to produce heat and reach reaction temperatures. Here, this work presents an in-depth understanding of the effect of the addition of silicon carbide as a microwave absorber on catalyst performance among other variables, the viability of the microwave reactor configuration, and insights into designing an effective and reliable microwave-based methane dehydroaromatization process. The effect of other parameters including temperature, weight hourly space velocity, role of microwave absorber, and methane concentration during microwave-assisted methane dehydroaromatization reaction are studied. Mo/ZSM-5 was found to suffer from low permittivity and nonuniform heating under microwave conditions. Mixing silicon carbide powder as a microwave absorber with the catalyst was found to provide more uniform heating. When assessing the catalytic performance of the mixture, it was found that higher methane partial pressures at 2000 cc/g cat .h and a temperature range of 500-600°C produced the highest amount of benzene. The formation of graphitic carbon on the spent catalyst increased with temperature, gas-solid contact period, and methane concentration, which resulted in higher methane conversion and benzene selectivity. The study indicates that under microwave heating the presence of localized carbon enhanced catalyst life by coupling with microwave energy, leading to localized heating, and improving benzene selectivity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing Low-Cost Methane Sensor Calibration Shortcomings with Machine Learning

Quantifying methane emissions is essential for meeting near-term climate goals and is typically carried out using methane concentrations measured downwind of the source. One major source of methane that is important to observe and promptly remediate is fugitive emissions from oil and gas production sites but installing methane sensors at the thousands of sites within a production basin is expensive. In recent years, relatively inexpensive metal oxide sensors have been used to measure methane concentrations at production sites. Current methods used to calibrate metal oxide sensors have been shown to have significant shortcomings, resulting in limited confidence in methane concentrations generated by these sensors. To address this, we investigate using machine learning (ML) to generate a model that converts metal oxide sensor output to methane mixing ratios. To generate test data, two metal oxide sensors, TGS2600 and TGS2611, were collocated with a trace methane analyzer downwind of controlled methane releases. Over the duration of the measurements, the trace gas analyzer’s average methane mixing ratio was 2.40 ppm with a maximum of 147.6 ppm. The average calculated methane mixing ratios for the TGS2600 and TGS2611 using the ML algorithm were 2.42 ppm and 2.40 ppm, with maximum values of 117.5 ppm and 106.3 ppm, respectively. A comparison of histograms generated using the analyzer and metal oxide sensors mixing ratios shows overlap coefficients of 0.95 and 0.94 for the TGS2600 and TGS2611, respectively. Overall, our results showed there was a good agreement between the ML-derived metal oxide sensors’ mixing ratios and those generated using the more accurate trace gas analyzer. This suggests that the response of lower-cost sensors calibrated using ML could be used to generate mixing ratios with precision and accuracy comparable to higher priced trace methane analyzers. This would improve confidence in low-cost sensors’ response, reduce the cost of sensor deployment, and allow for timely and accurate tracking of methane emissions.

03 NATURAL GAS↗

UT-GOM2-2 Preliminary Report: Terrebonne Basin Northern Gulf of Mexico, 30 July-28 September 2023

In the summer and fall of 2023, the Gulf of Mexico Deepwater Hydrate Coring Expedition (UT-GOM2-2) drilled, cored, made downhole measurements, and analyzed samples from the seafloor to the base of the gas hydrate stability zone in one location (Site H, WR313) in the Terrebonne basin, deepwater Gulf of Mexico. Analyses of data and samples from the expedition will inform biological, geochemical, and geomechanical models to constrain the role of gas hydrates in the carbon cycle and the potential for gas hydrates as an energy resource. Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were obtained. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of ~200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The biogenic ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years) with a pronounced increase in sedimentation rate with depth. Beneath 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C 1 /C 2 ) and the methane to ethane plus propane (C 1 /(C 2 +C 3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ 13 C isotopic signature of methane ranges between -69.9 and -78.5 ‰ Vienna Pee Dee Belemnite (VPDB). Pressure core recovery of all sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

Expedition UT-GOM2-2 Site H

Pressure and conventional cores were collected at Site H of the Walker Ridge Protracted Area Block 313 in the Terrebonne Basin, deepwater Gulf of America (Gulf of Mexico) during the University of Texas (UT) Deepwater Hydrate Coring Expedition (UT-GOM2-2). Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were recovered. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of about 200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. These ooze intervals also correspond to lighter sediment color, increased Ca content based on X-ray florescence (XRF) core scanning, and increased calcareous nannofossil abundance. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years), with a pronounced increase in sedimentation rate with depth. Below 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C1 /C2 ) and the methane to ethane plus propane (C1 /(C2 +C3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ13C isotopic signature of methane ranges between -69.9 and -78.5 ‰ relative to the Vienna Pee Dee Belemnite (VPDB) standard. Pressure core recovery in sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One pressure core was degassed and the average hydrate saturation in the core was determined to be 24%. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗

Intrinsic kinetics of water-inhibited ultra-lean methane oxidation over PtPd-Mg/ θ -Al 2 O 3 catalyst

Here, this study develops intrinsic methane oxidation kinetics for ultra-lean methane conditions in the presence of water over a highly active and stable PtPd–Mg/θ-Al 2 O 3 catalyst. Comprehensive laboratory experiments were conducted over a wide range of methane concentrations (150–1200 ppm CH 4 ), water contents (1–5% H 2 O), and industrially relevant space velocities (80,000 ≤ GHSV ≤ 160,000 h -1 ). These systematic experiments informed a two-dimensional, axisymmetric, multiscale reactor model that was used to develop and validate methane oxidation kinetics under practically relevant conditions, including non-isothermal operation and high conversion regimes. Combined experimental and modeling results revealed significant intraparticle diffusion resistance and transport-induced reaction exotherm at elevated temperatures, which limited catalyst utilization despite high intrinsic activity. These transport effects were explicitly incorporated into the reactor model, enabling accurate estimation of intrinsic kinetic parameters without reliance on conventional effectiveness-factor corrections. The resulting kinetic model successfully captured both kinetically controlled and mass-transfer-limited regimes and reliably predicted CH 4 conversion across broad ranges of temperature, methane concentration, and water content

Heat and mass transfer limitations↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Numerical Study on the Effect of Methane Doping in Hydrogen-Air Rotating Detonation Engines for Various Temperatures and Pressures

Rotating detonation engines (RDEs) have gained attention as a promising technology for future aviation engines. However, the numerical studies of these systems pose severe challenges due to the broad range of spatial and temporal scales. In this study, we use an adaptive mesh refinement based compressible, reactive solver PeleC to resolve the broad range of scales and accurately capture shock and detonation waves using high-resolution numerical schemes. Multi- species transport along with compressible Navier-Stokes equations are solved in the model along with a finite-rate based chemistry model. Embedded boundary method is used to model the complex geometry consisting of discrete fuel nozzles and the combustion chamber. The fuel consisting predominantly of hydrogen is doped with varying levels of methane while air is used as the oxidizer. For a specified total pressure and temperature, the number of stable detonation waves is found to decrease with increasing methane concentration in the fuel mixture. Additionally, no stable detonation solutions are observed for methane composition higher than 20% by volume for the range of operating conditions studied (300-900K, 10 Atm). The increased presence of high temperature zones is also indicative of higher thermal NOx emissions at low methane concentrations. The effect of fuel-air mixture composition and temperature on the detonability, detonation wave structure, mode transitions and their stability are analyzed in this study in addition to their implication on NOx emission.

automatic mesh refinement↗