Engineering PapersSearch

SEARCH · Engineering Papers

Results for “inverter blocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dronebase Photovoltaic (PV) Fleet Imagery Quantitative Evaluation (CRADA CRD-22-22941 Final Report)

Combine the Dronebase aerial imagery with corresponding sites in the NLR Photovoltaic (PV) Fleets database. By combining these two data sources in an aggregated, anonymized fashion, we can perform the following analyses: quantifying power loss due to outages caused by stuck trackers, string outages, and shading/snow, validate site metadata, including tilt and azimuth, and correlate.

14 SOLAR ENERGY

UNIFI Specifications for Grid-Forming Inverter-Based Resources: Version 3

The UNiversal Interoperability for grid-Forming Inverters (UNIFI) Consortium addresses fundamental challenges facing the integration of grid-forming (GFM) inverters in electric grids alongside rotating machines and other inverter-based resources (IBRs). This document defines a set of UNIFI specifications for GFM IBRs that provides requirements from both a power system level as well as functional requirements at the inverter level that are intended to provide means for the vendor-agnostic operation of GFM IBRs at any scale in electric power systems.

14 SOLAR ENERGY

Integrated Inverter And Battery Charger

Circuit combines functions of dc-to-ac inversion (for driving ac motor in battery-powered vehicle) and ac-to-dc conversion (for charging battery from ac line when vehicle not in use). Automatically adapts to either mode. Design of integrated inverter/charger eliminates need for duplicate components, saves space, reduces weight and cost of vehicle. Advantages in other applications : load-leveling systems, standby ac power systems, and uninterruptible power supplies.

Rippel, Wally E.

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control

Evaluations of Additively Manufactured Superalloy Lattice Blocks

Cast lattice block structures made up of high-temperature superalloys were previously shown to offer advantages in density, efficiency, and tailored properties. However, inconsistencies in casting die-fill, composition, and microstructure were identified as persistent issues with the casting process path. Three candidate lattice designs were screened through additive manufacturing of a superalloy. Laser powder bed fusion was applied with superalloy powder to produce lattice blocks for three-dimensional octahedral unit-cell designs of three heights. Properties of the structural designs versus additively manufactured lattices were compared, including structural dimensions, densities, defects, grain structures, crystallographic texture, and surface residual stresses. Findings indicate this concept could produce useful superalloy structures for high-temperature-capable static components requiring tailored density, and thermophysical and mechanical properties.

superalloy

Evaluation of Superalloy 718 Additively Manufactured Lattice Blocks

Lattice block structures made up of high temperature superalloys could offer advantages in density, efficiency, and tailored properties. Three candidate lattice designs were screened through additive manufacturing of superalloy 718. Laser powder bed fusion was applied with 718 powder to produce lattice blocks for three-dimensional octahedral unit cell designs of three heights. As-designed versus additively manufactured 718 lattices were compared, including structural dimensions, densities, defects, grain structures, crystallographic texture, and surface residual stresses. Manufactured lattice I diverged the most from its design, with both corner and center nodes merged into continuous columns. Manufactured lattice III came closest to its design, though the actual nodes and struts were still larger in cross section than in the design. Only modest grain coarsening and negligible chemical segregation were observed for all three designs, suggesting uniform thermo-physical and mechanical properties are possible. Significant tensile residual stresses were present at the surface of the manufactured blocks, with highest stresses in the building direction. Current findings indicate this concept could produce useful superalloy structures for high-temperature-capable static components requiring tailored density, and thermo-physical/mechanical properties.

super alloys

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)

Block-Type Antiferromagnetism in Single Chain Quasi-One-Dimensional K 3 ⁢Fe 2 ⁢Se 4

One-dimensional (1D) structures provide a unique platform to study the correlated quantum interactions and phase transitions such as unconventional magnetism and superconducting states. Here, we report that iron chalcogenide K 3 ⁢Fe 2 ⁢Se 4 exhibits an unusual block-type canted antiferromagnetic (AFM) order with a clear single chain quasi-1D structure, which is structurally different from the two-leg ladder BaFe 2 ⁢Se 3 , through both experimental measurements and density matrix renormalization group (DMRG) calculations. The narrow bandgap semiconductor K 3 ⁢Fe 2 ⁢Se 4 has a quasi-1D edge-shared FeSe4 tetrahedra chain structure and orders antiferromagnetically below 110 K. The magnetic moments couple antiferromagnetically along the quasi-1D chain direction of the 𝑏 axis and form an up-down-down-up (↑−↓−↓−↑)–like spin structure with a commensurate propagation vector 𝒌=⁢(0,0,0), where block-type spin ↑−↑ or ↓−↓ coupling are between the longer Fe-Fe bonds of the quasi-1D chain. DMRG results show that block antiferromagnetic state is stable in K 3 ⁢Fe 2 ⁢Se 4 and reveal that the block-ordered arrangement of Fe 2.5+ ions spins arise from the competition between ferromagnetic and AFM interaction in the presence of strong electronic correlation. Our research results not only report the discovery of a clear block-type canted antiferromagnetic structure in a real quasi-1D chain material but also provide a theoretical approach to understand the block-type antiferromagnetism in quasi-1D iron chalcogenides.

antiferromagnetism

Developing a Pyrolysis Gas Thermal Blocking Model for Reentry Demise

In NASA’s Object Reentry Survival Analysis Tool (ORSAT), aerodynamic drag and aerothermal heating coefficients are computed for each of the free-molecular, continuum, and transitional flow regimes using analytical and semi-analytical methods. These heating coefficients were derived for typical metallic materials that melt and do not have a strong gas-phase contribution to the flow in the boundary layer. Modern satellites typically feature fiber-reinforced polymer (FRP) components, such as solar array booms, facesheets of sandwich panels, or overwraps for composite-overwrapped pressure vessels (COPV). These FRP materials do not behave the same as metals in the reentry environment, but instead will pyrolyze and develop significant volumes of gas into the boundary layer. Accurately predicting the reentry demise of FRP components is critical to assessing the reentry casualty risk for modern spacecraft. Research in recent years has shown that this demisability can depend heavily on how the expulsion of gaseous pyrolysis products through the outer surface of the material affects the heat flux at the surface. The ODPO has been developing a reduced-order model of the effect of pyrolysis gas blowing on the heat flux based on correlations between a blowing factor and a non-dimensional heat flux to be incorporated in the upcoming version 7.3 of the Object Reentry Survivability Analysis Tool (ORSAT). This presentation discusses the progress of this development project and the challenges remaining for generalizing the model across families of FRP materials.

Benton Greene

Block copolymer self-assembly derived mesoporous magnetic materials with three-dimensionally (3D) co-continuous gyroid nanostructure

Magnetic nanomaterials are gaining interest for their many applications in technological areas from information science and computing to next-generation quantum energy materials. While magnetic materials have historically been nanostructured through techniques such as lithography and molecular beam epitaxy, there has recently been growing interest in using soft matter self-assembly. In this work, a triblock terpolymer, poly(isoprene-block-styrene-block-ethylene oxide) (ISO), is used as a structure directing agent for aluminosilicate sol nanoparticles and magnetic material precursors to generate organic–inorganic bulk hybrid films with co-continuous morphology. After thermal processing into mesoporous materials, results from a combination of small angle X-ray scattering (SAXS) and scanning electron microscopy (SEM) are consistent with the double gyroid morphology. Nitrogen sorption measurements reveal a type IV isotherm with H1 hysteresis, and yield a specific surface area of around 200 m 2 g −1 and an average pore size of 23 nm. The magnetization of the mesostructured material as a function of applied field shows magnetic hysteresis and coercivity at 300 K and 10 K. Comparison of magnetic measurements between the mesoporous gyroid and an unstructured bulk magnetic material, derived from the identical inorganic precursors, reveals the structured material exhibits a coercivity of 250 Oe, opposed to 148 Oe for the unstructured at 10 K, and presence of remnant magnetic moment not conventionally found in bulk hematite; both of these properties are attributed to the mesostructure. This scalable route to mesoporous magnetic materials with co-continuous morphologies from block copolymer self-assembly may provide a pathway to advanced magnetic nanomaterials with a range of potential applications.

Chemistry