Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiation Effect On Gas Electron Multiplier Detector Performance

Gas Electron Multiplier (GEM) detector is a gas device with high gain and high efficiency. These detectors use chemically perforated 65 {mu}m thick copper clad Kapton polyimide foils. Given its potential for detecting X-rays and other radiations, GEM detectors may be used in an environment with high radioactivity. The Kapton foils manufacturer, Du Pont Inc., claims that the foils are radioactive resistant. To verify whether the GEM detector performance is affected by the exposure to radiation, several GEM foils were irradiated to a {sup 60}Co source at the gamma-ray irradiation facility at Sterigenics, Tustin, CA. Four sets of GEM foils were exposed to the level of 10 kGy, 100 kGy, 1,000 kGy and 10,000 kGy. The output signal from the GEM detectors with irradiated GEM foils were measured and compared to the detector with no irradiation. We observed that the shapes of the peaks from 5.9 KeV {sup 55}Fe X-ray were distorted and that the detector gain increased compared to that of the un-irradiated detector. In particular, the detector with 10,000 kGy irradiation appeared to have the biggest peak distortion and increased gain. It was also found from that additional electrons from radiation-induced free radicals in the Kapton film contribute to output signal of the irradiated GEM detectors. Further studies are needed to explain the mechanism of these detector performance changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Large Area Gas Electron Multiplier Detector and Its Application to a Digital Hadron Calorimeter for Future Collider Experiments

The UTA High Energy Physics Group conducted generic detector development based on large area, very thin and high sensitivity gas detector using gas electron multiplier (GEM) technology. This is in preparation for a use as a sensitive medium for sampling calorimeters in future collider experiments at the Energy Frontier as well as part of the tracking detector in Intensity Frontier experiments. We also have been monitoring the long term behavior of one of the prototype detectors (30cmx30cm) read out by the SLAC-developed 13-bit KPiX analog chip over three years and have made presentations of results at various APS meetings. While the important next step was the development of large area (1m x 1m) GEM planes, we also have looked into opportunities of applying this technology to precision tracking detectors to significantly improve the performance of the Range Stack detector for CP violation experiments and to provide an amplification layer for the liquid Argon Time Projection Chamber in the LBNE experiment. We have jointly developed 33cmx100cm large GEM foils with the CERN gas detector development group to construct 33cm x100cm unit chambers. Three of these unit chambers will be put together to form a 1m x 1m detector plane. Following characterization of one 33cmx100cm unit chamber prototype, a total of five 1m x 1m planes will be constructed and inserted into an existing 1m3 RPC DHCAL stack to test the performance of the new GEM DHCAL in particle beams. The large area GEM detector we planned to develop in this proposal not only gives an important option to DHCAL for future collider experiments but also the potential to expand its use to Intensity Frontier and Cosmic Frontier experiments as high efficiency, high amplification anode planes for liquid Argon time projection chambers. Finally, thanks to its sensitivity to X-rays and other neutral radiations and its light-weight characteristics, the large area GEM has a great potential for the use in medical imaging and homeland security, as well as satellite based astronomy experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Sealed, UHV Compatible, Soft X-ray Detector Utilizing Gas Electron Multipliers

An advanced soft X-ray detector has been designed and fabricated for use in synchrotron experiments that utilize X-ray absorption spectroscopy in the study a wide range of materials properties. Fluorescence X-rays, in particular C{sub K} at 277eV, are converted in a low pressure gas medium, and charge multiplication occurs in two gas electron multipliers, fabricated in-house from glass reinforced laminate, to enable single photon counting. The detector satisfies a number of demanding characteristics often required in synchrotron environments, such as UHV compatibility compactness, long-term stability, and energy resolving capability.

43 PARTICLE ACCELERATORS↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collaborative Research: Equipment for and Running of the PSI MUSE Experiment

The R&D funding from this award has been a significant tool to move the Muon Scattering Experiment (MUSE) at the Paul Scherrer Institute in Switzerland forward to the stage of realization. Specifically, this award has enabled Dr. Michael Kohl and his working group at Hampton University to achieve substantial progress toward the goal of providing beam particle tracking with Gas Electron Multiplier (GEM) detectors for MUSE experiment. Establishing a particle detection system that is capable of operating in a high-intensity environment, with a data acquisition system capable of running at several kHz, combined with robust tracking software providing high efficiency for track reconstruction in the presence of noise and backgrounds will have immediate application in many other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

PSMC Upgrade Development Documentation and Functional Testing

The functional verification consists of verifying that the calibration (a.k.a. gain matching) is accurate and that there is no double pulsing or signal cross talk and interference. The calibration is shown to be satisfactory from the plateau plots on the right. The absence of double pulsing and cross talk can be seen in the time-interval diagram below. Both phenomena are manifested by spikes in the time interval distribution around 1µs to 5µs. No such spike is present.

3-He detector electronics↗

Effective Gain and Ion Back Flow study of triple and quadruple GEM detector

Abstract Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Pattern Gaseous Detector (MPGD) category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several parameters define the performance of these types of devices under various experimental conditions. This article focuses on the study of effective gain and Ion Back Flow (IBF) in both triple and quadruple GEM detectors. Effective gain and IBF are two of the most important parameters in determining the performance of GEM detectors.

Instruments & Instrumentation↗

Analytical Method for the Detection of Ozone Depleting Chemicals (ODC) in Commercial Products Using a Gas Chromatograph with an Electron Capture Detector (GC-ECD)

This document describes an analytical procedure that was developed for the trace level detection of residual ozone depleting chemicals (ODC) associated with the manufacture of selected commercial products. To ensure the United States meets it obligation under the Montreal Protocol, Congress enacted legislation in 1989 to impose an excise tax on electronic goods imported into the United States that were produced with banned chemicals. This procedure was developed to technically determine if residual ODC chemicals could be detected on electronic circuit boards. The analytical method utilizes a “purge and trap” technique followed by gas chromatography with electron capture detection to capture and analyze the volatile chemicals associated with the matrix. The method describes the procedure, the hardware, operating conditions, calibration, and quality control measures in sufficient detail to allow the capability to be replicated. This document corresponds to internal Standard Operating Procedure (SOP) EFL-130A, Rev 4.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distribution of polychlorinated biphenyls and organochlorine pesticides in human breast milk from various locations in Tunisia: Levels of contamination, influencing factors, and infant risk assessment

The concentrations of dichlorodiphenytrichloroethane and its metabolites (DDTs), hexachlorobenzene (HCB), hexachlorocyclohexane isomers (HCHs), dieldrin, and 20 polychlorinated biphenyls (PCBs) were determined in 237 human breast milk samples collected from 12 locations in Tunisia. Gas chromatography with electron capture detector (GC-ECD) was used to identify and quantify residue levels on a lipid basis of organochlorine compounds (OCs). The predominant OCs in human breast milk were PCBs, p,p'-DDE, p,p'-DDT, HCHs, and HCB. Concentrations of DDTs in human breast milk from rural areas were significantly higher than those from urban locations (p<0.05). With regard to PCBs, we observed the predominance of mid-chlorinated congeners due to the presence of PCBs with high K{sub ow} such as PCB 153, 138, and 180. Positive correlations were found between concentrations of OCs in human breast milk and age of mothers and number of parities, suggesting the influence of such factors on OC burdens in lactating mothers. The comparison of daily intakes of PCBs, DDTs, HCHs, and HCB to infants through human breast milk with guidelines proposed by WHO and Health Canada shows that some individuals accumulated OCs in breast milk close to or higher than these guidelines.

60 APPLIED LIFE SCIENCES↗

Organochlorine pesticides and polychlorinated biphenyls in human adipose tissue from northern Tunisia: Current extent of contamination and contributions of socio-demographic characteristics and dietary habits

The aims of the present study were to investigate the current exposure levels of persistent organochlorine compounds (OCs) in adipose tissues intraoperatively collected from 40 patients over 20 years undergoing non-cancer-related surgery residing in Northern region of Tunisia (Bizerte), which constitutes an exemplary case, and examined association between levels of contamination and both socio-demographic characteristics and dietary habits. Concentration of hexachlorobenzene (HCB), hexachlorocyclohexane isomers (α-HCH, β-HCH, γ-HCH and δ-HCH), dichlorodiphenyltrichloroethane isomers (p,p′-DDT and o,p′-DDT) and metabolites (p,p′-DDE, o,p′-DDE, p,p′-DDD and o,p′-DDD) and 12 polychlorinated biphenyls (PCBs) congeners were measured using capillary gas chromatography with electron capture detector. Overall, residue levels of OCs followed the decreasing order of DDTs > PCBs > HCB > HCHs. DDTs levels ranged from 74.49 to 1834.76 ng g{sup −1} lipid and contributing to more than 90% to the sum of organochlorine pesticides (OCPs). p,p′-DDE was the most abundant in all samples and the p,p′-DDT/p,p′-DDE ratio (range between 1.85% and 58.45%) suggesting recent and ongoing exposure to banned commercial DDT products. PCB concentrations varied from 29.27 to 322.58 ng g{sup −1} lipid and PCB-180, PCB-153 and PCB-138 were the dominant congeners accounting for 70% of total PCBs. We did not find significant correlations between OC exposure levels and sex, parity, habitat areas and smoking habits. In females, the adipose tissue concentrations of DDTs, HCB and PCB-118 were positively correlated with age. There was statistically significant relationship between body mass index (BMI) changes and the adipose tissue levels of HCB and HCHs. No association was found between OCPs levels and dietary factors. However, our study suggests that fish consumption may be an important contributor of PCBs adipose tissue content of PCBs in Tunisian people. The presented work is highly significant, being the first study pointing out the chronic exposure to OCs in Bizerte. - Highlights: • First study to report HCB, HCHs, DDTs and PCBs in adipose tissues from Tunisia. • The measurement levels showed a general pattern as DDTs>PCBs> HCB>HCHs. • p,p′-DDE and PCB-180, PCB-153 and PCB-138 were the marker substances of OCPs and PCBs, respectively. • Strong associations between concentrations of OCPs and PCBs suggest Tunisian are exposed via similar routes. • Fish consumption is a major source of dietary exposure to PCBs.

54 ENVIRONMENTAL SCIENCES↗

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

We present that a large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d/d. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. Finally, the d/d resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the GEM-MSTPC for studies of astrophysical nuclear reaction rates

We have developed an active-target type gas-detector, a Gas Electron Multiplier Multiple-Sampling and Tracking Proportional Chamber (GEM-MSTPC) operating with low-pressure He-base mixed gas, where He is used as a target for studies of astrophysical nuclear reaction rates. Different kinds of 400 {mu}m thick GEMs were examined. The gain stability was examined with a configuration of GEMs of 400 {mu}m in thickness fabricated in different ways, against the injection rate of low-energy heavy ions of 10{sup 5} particles per second. The gain of GEM with Cu electrodes coated by Au was observed to be stable up to the injection rate of 10{sup 5} particles per second.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.↗

Calibration of a Gas Monitor Detector using a Cryogenic Radiometer for Measuring the Radiant Power of Extreme Ultraviolet Free Electron Laser at SPring-8

A gas monitor detector was calibrated to a cryogenic radiometer for measuring the radiant power of EUV-FEL (extreme ultraviolet free electron laser) at the wavelengths of 51 nm and 61 nm. The output signals of the gas monitor detector showed good linearity against the radiant power measured by the radiometer in the range from 6 {mu}W to 160 {mu}W. The calibration coefficients of the gas monitor detector are determined with the relative standard uncertainty of around 5 %.

43 PARTICLE ACCELERATORS↗

Prenatal dichlorodiphenyldichloroethylene (DDE) exposure and child growth during the first year of life

Background: Due to its long-term persistence in the environment and its ability to cross the placental barrier, prenatal p,p Prime -dichlorodiphenyldichloroethene (DDE) exposure continues to be a public health concern. This study aimed to evaluate the association between prenatal DDE exposure and child growth, at birth and during the first year of life. Methods: 253 pregnant women were recruited between January 2001 and June 2005 in a prospective cohort in Morelos, Mexico. Serum levels of DDE were measured during each trimester of pregnancy by gas chromatography with an electron capture detector. Using the generalized mixed-effects models, the association between DDE and child growth parameters (weight-for-age, length-for-age, weight-for-length, BMI-for-age and head circumference-for-age Z-scores) from birth to 1 year of age was assessed. Maternal dietary intake was considered as covariable among others. Results: DDE levels were 6.3{+-}2.8 ng/mL (first trimester), 6.6{+-}2.9 ng/mL (second trimester), and 7.6{+-}2.9 ng/mL (third trimester). After adjusting for potential confounder variables, no significant associations were observed with prenatal DDE exposure and each of the selected parameters. Conclusions: Our results show no evidence of an association between prenatal DDE exposure and child growth during the first year of life.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

Characterization of a 2D soft x-ray tomography camera with discrimination in energy bands

A gas detector with a 2D pixel readout is proposed for a future soft x-ray (SXR) tomography with discrimination in energy bands separately per pixel. The detector has three gas electron multiplier foils for the electron amplification and it offers the advantage, compared with the single stage, to be less sensitive to neutrons and gammas. The energy resolution and the detection efficiency of the detector have been accurately studied in the laboratory with continuous SXR spectra produced by an electronic tube and line emissions produced by fluorescence (K, Fe, and Mo) in the range of 3-17 keV. The front-end electronics, working in photon counting mode with a selectable threshold for pulse discrimination, is optimized for high rates. The distribution of the pulse amplitude has been indirectly derived by means of scans of the threshold. Scans in detector gain have also been performed to assess the capability of selecting different energy ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗