Engineering PapersSearch

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Anomaly Detection for Online Monitoring of Thermocouple Sensors in the Advanced Test Reactor

This study explores data-driven anomaly detection methods to analyze sensor fail- ures in the Advanced Gas Reactor (AGR) nuclear fuel irradiation experiments. Specifically, we examine failures of thermocouples (TCs), which are critical for mon- itoring and controlling in-reactor temperatures during operation. Failures were pri- marily observed during abrupt power transitions and manifested as sensor drop-outs, drifts, or unexplained behavior. We applied three time-series analysis techniques— rolling mean smoothing, matrix profile, and vector auto-regression (VAR)—to de- tect anomalies in TC data prior to failure events. The rolling mean method effec- tively highlighted deviations aligned with reported failures, while the matrix profile provided partial early warning but sometimes flagged normal fluctuations during power-down periods. VAR shows potential in capturing multivariate dependencies but requires further calibration. A rare case of TC drift was also documented, which did not result in failure, underscoring the challenge of building predictive models with sparse positive examples. Our findings demonstrate that traditional statistical tools can aid anomaly detection but have limited predictive power without richer training data. We propose future directions including synthetic data generation, real- time surrogate modeling, and multi-modal feature integration. This work provides a foundation for applying robust anomaly detection frameworks to mission-critical sensor systems in experimental settings.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Enhanced Component Performance Study: Motor-Operated Valves 1998-2024

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • High-demand MOV SO failure rate • Low-demand MOV frequency of FTOC events (failures per reactor year) • High-demand MOV frequency of SO events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS

Enhanced Component Performance Study: Motor Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Strain to failure measurements of Cr coatings with different processing

Differently processed Cr coatings on Zircaloy cladding were assessed for coating strain to failure. This report includes i) quantification of Cr coating strain to failure for several coating variants, ii) incorporation of high throughput analysis developed utilizing artificial intelligence, and iii) develop a hoop direction coating strain to failure testing approach for high temperatures that doesn’t require digital image correlation strain measurements. Room temperature strain to failure measurements indicated that heat treatment had an impact on strain to failure of the coating, with increasing heat treatment temperature increasing the average strain to failure of the Cr coating.

36 MATERIALS SCIENCE

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY

Interim Development of new Class B Code Case with Variable Design Lifetime and enhanced design rules to guard against cyclic structural failure mode

This report summarizes updates on the ongoing development of the new American Society of Mechanical Engineers Section III, Division 5, Class B rules to address the potential failure modes of Class B components. An initial design-by-analysis approach and supporting design rules are presented. The elastic-perfectly plastic (EPP) analysis approach has been adopted for primary stress limit and ratcheting check to prevent the component failure against the structural failure mode against primary load and strain accumulation due to cyclic loads. The creep-fatigue damage assessment uses explicitly defined elastic follow-up calculated from the stress concentration region of given component. Damage fraction calculation uses a novel coupled approach to capture the influence of the elastic follow-up and provide adequate conservatism for Class B components. The proposed Class B rules does not use the stress classification approach and uses the combined loads to assess component.

36 MATERIALS SCIENCE

ACT University Collaboration Proposal: Role of manufacturing defects on material failure under dynamic loading for developing enhanced failure models and theories (Final Report)

Research on the tensile behavior of additively manufactured 316L stainless steel coupon specimens at increasing strain rates was conducted over the past year at Penn State. Dynamic loading rates into the 1000 1/s loading rates were performed on specimens with nearly 1.32” gage lengths. Stress-strain plots show ductile and plastic behavior well beyond 12% strain with necked specimens, having smaller effective gage lengths showing up to 56% ultimate strain. Additional tests performed on compact tension specimens helped with simulation work to understand the deformation behavior. Using finite elements, it was possible to determine the feasibility of a comprehensive experimental validation study towards an improved model for AM material failure – specifically, the Bai-Wierzbicki approach which accounts for lode angle and triaxiality. A non-significant number of tests are projected for eight specific failure nodes, with additional replicates to provide strain-rate capabilities to the existing formulation. One such correction factor is explored for quasi-static, notched specimens. Finally, stress intensity factor was explored using a set of compact-tension specimens which would also provide useful validation data for any simulation work.

36 MATERIALS SCIENCE

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.

Safety Hazards of Batteries and Hydrogen Storage Systems in Proximity

This report addresses the safety concerns and mitigations for battery failures and their impact on hydrogen storage systems. Through an analysis of failure modes, this report highlights the risks posed by thermal runaway and chemical emissions caused by batteries. Although rare, battery thermal failure events may prompt the opening of the relief valve on the hydrogen tank. Strategies such as battery management systems, thermal management systems, and multiple thermally activated pressure relief devices can mitigate these risks. Potential simulations and experiments to better quantify the unique risks posed by lithium-ion batteries near tanks are suggested. Improving safety standards will enable integration of batteries and hydrogen storage systems in various energy storage technologies.

08 HYDROGEN

Understanding failure in austenitic steels: Key considerations for molten salt storage in CSP applications

Owing to their excellent properties, austenitic stainless steels are extensively used in boilers, furnaces, molten salt tanks, and other applications that are subjected to extreme mechanical loads and high-temperature conditions. Their high corrosion and creep resistance make them suitable for high-temperature operating environments. Additionally, good fatigue resistance and favorable mechanical and visual properties are essential. However, the premature failure of several components at elevated temperatures has been previously reported. Although the failure analysis of components in service is complex, processes such as cold work and welding have been identified as contributing factors to the performance degradation of these steels. This study aims to analyze the various documented failure modes and mechanisms in austenitic steels, including creep, cracking, stress relaxation cracking, and fatigue, to better understand the multi-objective design requirements for these alloys as structural materials for high-temperature molten salt tanks in Concentrating Solar Power (CSP) plants. Stabilized austenitic grades, such as AISI 347H, demonstrate superior resistance to creep and corrosion-related degradation when compared to non-stabilized grades like AISI 316L at temperatures relevant to concentrated solar power (CSP) applications. In contrast, nickel-based alloys offer enhanced corrosion resistance, albeit at a higher cost. This review underscores that creep, stress relaxation cracking, and thermo-mechanical fatigue are the predominant long-term failure risks in CSP hot tanks.

14 SOLAR ENERGY

Durability Optimization of CO 2 Electrolyzers for Syngas Evolution

Recently, there has been an increased interest in mitigating anthropogenic CO 2 emissions through the electrochemical conversion of CO 2 into fuels and fuel feedstocks, including hydrogen gas (H 2 ), carbon monoxide (CO), and mixtures of the two to yield syngas. Commercial applications of these systems require high catalytic selectivity for the desired products, while exhibiting operational lifetimes exceeding thousands of hours. Advancements in this field have produced systems that display high selectivity of the desired products at faradaic efficiencies exceeding 95%. Despite the advancements made in CO 2 electrolysis, system durability remains a standing challenge in the field. CO 2 electrolyzer lifetimes are often limited by carbonate fouling, catalyst degradation, detrimental flooding of electrode microporous layers and anion exchange membrane (AEM) failures. In this report, a 5 cm 2 membrane electrode assembly (MEA) device is used to investigate potential failure modes and to optimize AEM CO 2 electrolyzer operation. Key findings of this study include the importance of CO 2 flow rate, use of a thin PiperION PTFE-reinforced membrane, optimizing compression to enhance contact under 40 in-lb compression, and the effect of more compressible, commercial iridium oxide anodes on system durability.

Abouremeleh, Mohammed H. [Lawrence Berkeley Nation

Design Methods, Tools, and Data for Ceramic Solar Receivers

This report presents the development of tools and methods for evaluating the reliability and performance of ceramic materials in high temperature solar receivers. As Concentrating Solar Power (CSP) technologies aim for higher operating temperatures to enhance efficiency and meet industrial process heat requirements, current high temperature metallic materials face challenges in maintaining structural integrity. This report explores advanced ceramics as a promising alternative, given their superior high temperature strength and lower thermal expansion, compared to metals. To address the need for effective ceramic receiver design tools, this report integrates statistical failure models of ceramics into the existing srlife tool: an open-source software package designed to estimate the life of high temperature CSP components. These failure models account for the inherent variability and flaw distribution in ceramics, as well as the impact of subcritical crack growth under high temperature cyclic loads. The report also presents experimental data collected for a commercially available ceramic material, SiC, and details the process of estimating reliability model parameters from these data. A comparative design analysis is then performed between ceramic (SiC) and metallic (current nickel-based superalloys A740H and A282) receiver. This comparison demonstrates that SiC receivers can achieve service life exceeding 30 years under high incident heat flux conditions, compared to just a few years for metallic receivers.

14 SOLAR ENERGY

Adapting Traditional Hazards Analysis Methods to Address Cyber Risks

Traditional hazards analysis (HA) methods, originally developed to address physical and operational risks, often fall short when it comes to identifying and mitigating cyber threats. These cyber threats pose unique and evolving risks to critical infrastructure and industrial control systems (ICS). This report explores the integration of Cyber-Informed Engineering (CIE) principles into existing HA methods to enhance their ability to address cyber-induced risks. CIE provides organizations with a practical, cost-effective approach to closing the gap between traditional HA methods and the need for cyber risk mitigation. By leveraging existing safety processes and controls, CIE allows users to examine and mitigate cyber vulnerabilities without overhauling existing HA methods. This report identifies areas where HA and CIE naturally align and where their approaches diverge. It emphasizes how CIE principles can be used to adapt HA methods, broadening their scope to include cyber risks and enabling the mitigation of cyber- induced impacts alongside traditional hazards and failure scenarios. This report examines how CIE can be applied across various HA methods—such as Hazard and Operability Studies (HAZOP), Probabilistic Risk Assessment (PRA), Failure Modes and Effects Analysis (FMEA), Systems-Theoretic Process Analysis (STPA), Hazard and Consequence Analysis for Digital Systems (HAZCADS), and Layers of Protection Analysis (LOPA). It provides strategies for integrating CIE to strengthen the identification, assessment, and mitigation of cyber-induced risks. The findings offer a structured entry point for organizations to embed CIE concepts into hazards and safety analyses, as well as broader engineering processes, ultimately supporting the design and operation of a more resilient infrastructure.

42 ENGINEERING

Adapting Traditional Hazards Analysis Methods to Address Cyber Risks

Traditional hazards analysis (HA) methods, originally developed to address physical and operational risks, often fall short when it comes to identifying and mitigating cyber threats. These cyber threats pose unique and evolving risks to critical infrastructure and industrial control systems (ICS). This report explores the integration of Cyber-Informed Engineering (CIE) principles into existing HA methods to enhance their ability to address cyber-induced risks. CIE provides organizations with a practical, cost-effective approach to closing the gap between traditional HA methods and the need for cyber risk mitigation. By leveraging existing safety processes and controls, CIE allows users to examine and mitigate cyber vulnerabilities without overhauling existing HA methods. This report identifies areas where HA and CIE naturally align and where their approaches diverge. It emphasizes how CIE principles can be used to adapt HA methods, broadening their scope to include cyber risks and enabling the mitigation of cyber- induced impacts alongside traditional hazards and failure scenarios. This report examines how CIE can be applied across various HA methods—such as Hazard and Operability Studies (HAZOP), Probabilistic Risk Assessment (PRA), Failure Modes and Effects Analysis (FMEA), Systems-Theoretic Process Analysis (STPA), Hazard and Consequence Analysis for Digital Systems (HAZCADS), and Layers of Protection Analysis (LOPA). It provides strategies for integrating CIE to strengthen the identification, assessment, and mitigation of cyber-induced risks. The findings offer a structured entry point for organizations to embed CIE concepts into hazards and safety analyses, as well as broader engineering processes, ultimately supporting the design and operation of a more resilient infrastructure.

42 - ENGINEERING

Assessment of Potential Failure Modes and Effects for On-Board Components for Hydrogen-Powered Locomotives

Hydrogen fuel sources offer alternatives to conventional fuels in the rail transportation industry. Hydrogen powered locomotive designs utilizing either a fuel cell or an internal combustion engine can make migration to alternative fuels possible for rail transportation. Codes and standards are still in development for rail application of hydrogen and safety risks must be assessed for hydrogen locomotive applications. This report utilizes a failure mode & effects analysis framework to help qualitatively understand possible risks from a hydrogen locomotive system. Findings illustrate how a combination of three mitigations greatly reduces the risks from a hydrogen locomotive system.

08 HYDROGEN

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY

Evaluation of NETL’s Self-Healing Metallic Coating for Internal Corrosion Protection of Natural Gas Pipelines: Field Test

Steel pipelines are a safe, reliable, and affordable way to transport natural gas. However, the presence of impurities (e.g., water, carbon dioxide, and hydrogen sulfide) in the natural gas can cause internal corrosion, which can lead to pipeline leaks and failure. This paper reports on field tests of an innovative self-healing, corrosion-resistant, metallic coating developed at the National Energy Technology Laboratory (NETL) for protecting the interior surfaces of pipelines.

carbon dioxide (CO2)