Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Jet Impingement Cooling of Electric Machines with Driveline Fluids

In the presentation thermal management of electric traction drives is discussed and capabilities of NREL's Advanced Power Electronics and Electric Machines group is reviewed. Emphasis is made on jet impingement cooling technique of electric machines with driveline fluids and experimental measurements of associated heat transfer coefficients.

47 OTHER INSTRUMENTATION↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗

A code-to-code benchmark for magneto-convection in a horizontal duct

Liquid metals and magnetic fields are used in many technical applications such as metallurgy, crystal growth and nuclear fusion reactors. When an electrically conducting fluid moves in a magnetic environment, electric currents and electromagnetic forces are generated that affect velocity and pressure losses in the flow. These magnetohydrodynamic (MHD) interactions have to be investigated to optimize the engineering processes. The characteristics of MHD flows depend on the geometrical configuration, the strength of the applied magnetic field, the electrical properties of fluid and structural materials and the thermal conditions. In the so-called blankets for fusion reactors, where liquid metals are used to breed the plasma fuel component tritium and to extract the generated heat, magneto-convective flows play a crucial role in determining heat and mass transfer. Therefore, the availability of numerical codes to simulate this type of flow is mandatory and their validation is a necessary step to guarantee the reliability of the results. For that reason, a benchmark problem has been defined to simulate liquid metal flows in a horizontal rectangular duct heated from below and exposed to a non-uniform magnetic field. Results obtained by five research groups using different codes are compared.

benchmark↗

Electrically controlled interlayer trion fluid in electron-hole bilayers

Here, the combination of repulsive and attractive Coulomb interactions in a quantum electron-hole (e-h) fluid can produce correlated phases of multiparticle charge complexes, such as excitons, trions, and biexcitons. We report an experimental realization of an electrically controlled interlayer trion fluid in van der Waals heterostructures. In strongly coupled e-h bilayers, electrons and holes spontaneously form three-particle trion bound states. The interlayer trions can assume 1e-2h and 2e-1h configurations. We show that the two holes in 1e-2h trions form a spin-singlet with a spin gap of approximately one milli–electron volt. By electrostatic gating, the equilibrium state can be continuously tuned into an exciton fluid, a trion fluid, an exciton-trion mixture, or a trion-charge mixture. Our work demonstrates a platform to study correlated phases of tunable Bose-Fermi mixtures.

Qi, Ruishi [University of California, Berkeley, CA↗

Optimal Control of SOEC-Based Hydrogen Production Systems for Demand Response Using Deep Reinforcement Learning in Smart Grids

Solid oxide electrolysis cell (SOEC) hydrogen production technology can range in size from small, appliance-size equipment to large-scale, central production facilities that can be tied directly to renewable or non-greenhouse-gas-emitting forms of electricity production, making it an ideal resource for demand response (DR). The SOEC hydrogen production system is a complex integrated system that encompasses fluid dynamics, electrical dynamics, and electrochemical and thermal dynamics, all of which involve non-linearity and non-convexity. Proper control of the SOEC hydrogen production system is crucial to enable its participation in the DR program. Here, to overcome the difficulty of designing an explicit control law for such nonlinear systems with nonconvex optimization features in DR applications, deep reinforcement learning (DRL) is explored to achieve the optimal control of the SOEC system for DR participation. Specifically, a twin delayed deterministic policy gradient (TD3) control framework is applied to achieve optimal response performance during DR events by considering power tracking error and hydrogen production efficiency with a suitable reward function. Two case studies with grid connections for tracking different DR commands were investigated. The first case study involved operating conditions reaching the boundaries, while the second involved operating conditions within the boundaries. The results showed that the proposed DRL-based control for SOEC can track the DR signal in a timely manner while maintaining high energy efficiency.

08 HYDROGEN↗

Review of Wave Energy Converter Power Take-Off Systems, Testing Practices, and Evaluation Metrics: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. One of the difficulties that wave energy systems have been struggling to overcome is the design of highly efficient energy conversion systems that can convert the mechanical power, derived from the oscillation of wave activated bodies, into another useful product. Often the power take-off (PTO) is defined as the single unit responsible for converting mechanical power into another usable form such as electricity, pressurized fluid, compressed air, and others. The PTO, and the entire power conversion chain (PCC), is of great importance as it affects not only how efficient wave power is converted into electricity, but also contributes to the mass, size, structural dynamics, and levelized cost of energy (LCOE) of the wave energy converter (WEC). Unlike wind and solar, there is no industrial standard device, or devices, for wave energy conversion and this diversity is transferred to the PTO system. The majority of current WEC PTO systems incorporate a mechanical or hydraulic drive train, power generator, and an electrical control system. The challenge of WEC PTO designs is designing a mechanical-to-electrical component that can efficiently convert irregular, bi-directional, low frequency and low alternating velocity wave motions. While gross average power levels can be predicted in advance, the variable wave elevation input has to be converted into smooth electrical output and hence usually necessitates some type of energy storage system, such as battery storage, accumulator super capacitors, etc., or other means of compensation such as an array of devices. One of the primary challenges for wave energy converter systems is the fluctuating nature of wave resources, which require WEC components to be designed to handle loads (i.e. torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater PTO capacity than the average power output and indicates a higher cost. In addition, supporting mechanical coupling and or gearing can be added to the PCC to help alleviate the difficulties with transmission and control of fluctuating large loads with low frequencies (indicative of wave forcing) into smaller loads at higher frequencies (optimum for conventional electrical machine design) can quickly increase the complexity of the PCC which could result in a greater number of failure modes and increased maintenance costs. All of the previous points demonstrate how the PTO influences WEC dynamics, reliability, performance and cost which are critical design factors. This paper further explores these topics by providing a review of the state-of-the-art PTO systems currently under development, how these novel PTO systems are tested and derisked prior to precommercial deployment, and the evaluation metrics historically used to differentiate between PTO designs and how they can be improved to support control co-design focused development of wave energy systems.

laboratory testing↗

Apparatus and method for intrachannel defouling of a heat exchanger using induction heaters

An apparatus comprising a heat exchanger and one or more induction heating elements is disclosed. The heat exchanger comprises a coolant side conduit and a process side conduit, the process side conduit being susceptible to fouling by at least partial desublimation, condensation, crystallization, deposition, or combinations thereof of a fouling component of a circulating process fluid. An electrically conductive first metal is disposed adjacent to the process side conduit. The one or more induction heating elements are disposed proximate to the heat exchanger. The one or more induction heating elements are connected to a source of electrical current. When the electrical current flows through the induction heating elements, eddy currents are induced in the first metal, heating the first metal such that the fouling component sublimates, melts, absorbs, or a combination thereof into the circulating process fluid.

42 ENGINEERING↗

Integrated Traction Drive Thermal Management: Keystone Project 3

The presentation was developed for the U.S. Department of Energy (DOE) Vehicle Technologies Program 2020 Annual Merit Review and Peer Evaluation Meeting. It reports on progress and accomplishments of DOE funded Integrated Traction Drive Thermal Management project. Highlighted are NREL's research accomplishments during FY 2020. Challenges associated with thermal management of integrated traction drives for electric vehicles arise due to the limited packaging space, coolant distribution, electrical connections, and ambient temperatures. For this project at NREL, research focuses on enabling thermal management technologies to support a modular, compact, self-contained integrated electric drive unit with motor and power electronics. Integration approaches, based on packaging location and coolant options for power electronics integrated with candidate motor technologies to reduce cables and connectors, are reviewed and compared using finite element analysis (FEA) tools. Automatic transmission fluid (ATF) jet impingement cooling characterization is carried out experimentally (measuring heat transfer coefficients) and using computational fluid dynamics (CFD) modeling.

47 OTHER INSTRUMENTATION↗

Fast Computational Algorithms for Partial Differential Equations and Uncertainty Quantifications

This project concerned the construction, testing and analysis of computational algorithms for solving parameterized and stochastic partial differential equations. The study and understanding of equations of this type is of fundamental importance in numerous engineering and scientific applications. Examples include simulation of plasma dynamics in models of electric propulsion and nuclear fusion, simulation of multiphase flows, such as the flow of water, gas and oil in reservoirs, and structural analysis of the dependence of structures on materials. Parametrization is used in such settings when properties of the models such as viscosity of fluids or electric resistivity of materials are not precisely understood and instead are treated as random variables. The resulting solutions are themselves random, and having such solutions will enable engineers to use probabilistic methods to assess the likelihood of events, for example, whether a pollutant in a liquid will exceed a limit, and to use such analyses to develop ways to ensure positive outcomes. Construction of accurate (high resolution) computational solutions is expensive, requiring significant computer time and computational resources, and there is need to reduce computational cost to make simulation useful and effective. The aim of the project was to construct algorithms to efficiently compute surrogate solutions to parameterized problems to allow for efficient and accurate simulation. The technical approach used focused on two related strategies, based on rank-reduction methods and reduced-order models. These methods construct surrogate solutions of parameter-dependent models by projection or interpolation into low-dimensional approximation spaces. Cost savings are achieved if the low-dimensional spaces can be identified and constructed efficiently and if the resulting low-dimensional algebraic systems can be solved cheaply. Accomplishments include: Theoretical and empirical demonstration of the effectiveness of fast multigrid solution strategies for computing low-rank representations of parameter-dependent solutions to discrete partial differential equations, including the first proof establishing so-called textbook convergence properties for low-rank methods. Development of efficient solution algorithms for solving nonlinear parameter-dependent partial differential equations used in models of fluid dynamics. Developent of efficient algorithms for low-rank representation of solutions of time-dependent simulations of fluid dynamics using multi-dimensional tensor representations of solutions.

97 MATHEMATICS AND COMPUTING↗

Using Resin to Reduce Silica in Borated Fluid - 20072

The Electric Power Research Institute (EPRI) strongly recommends the concentration of silica in the reactor coolant be limited, potential ingress be carefully controlled, and frequently monitored to assess potential silica deposits on fuel cladding surfaces. Boraflex is a product with silicone rubber encasing a neutron absorber for criticality control, and it was installed in the majority of nuclear power plant spent fuel pools. Over time and in the presence of radiation, the silicone rubber lining degrades into silica (SiO{sub 2}) and hydrogen gas. Silica is somewhat soluble in water and spent fuel pool water communicates with other plant systems during refueling outages, leading to a buildup of silica in the reactor coolant and connected systems. Due to the prevalence of Boraflex racks in spent fuel pools, the presence of silica is a chronic nuclear industry concern. To address this concern, many nuclear plants have installed reverse osmosis skid systems to remove the silica from their spent fuel pools and, by extension, from reactor coolant. These skids are expensive to install and maintain. Arcadis personnel demonstrated that an iron-impregnated resin could be used to remove silica from borated systems without impacting the water quality. The resin was readily available, inexpensive, and easy to install in existing plant equipment. During a nuclear power plant's refueling outage the iron-impregnated resin proved to be effective in reducing the need for feed and bleed operations, with concurrent cost savings and reduction in required outage water management activities. Thus, the following savings were realized: - Eliminated the need to purchase, install, and maintain a reverse osmosis system avoiding more than $10 million in up-front capital cost and ongoing operating and maintenance costs. - Removed 9.57 kilograms (21 pounds) of silica dioxide from the primary system fluid. - Reduced the volume of feed and bleed from 70,000 gallons (2.65 E+05 liters) to 35,000 gallons (1.32 E+05 liters). - Saved $380,000 in water production and disposal costs. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of fluid inside pipe using multi frequency electrical signal

A multi-frequency signal may be used to induce voltage difference across a portion of a pipe. The voltage difference may be induced to take multi-frequency measurement of impedance characteristics of fluid inside the pipe. The multi-frequency measurement of the impedance characteristic of the fluid inside the pipe may be used to determine a characteristic of the fluid inside the pipe. This may be achieved by active integration of experimental data with high-resolution multi-frequency electrical impedance tomography (MFEIT) modeling.

Chillara, Vamshi Krishna↗

High-speed imaging of transition from fluid breakup to phase explosion in electric explosion of tungsten wires in air

High-speed visible imaging of sub-microsecond electric explosion of wires at the low specific energy deposition threshold reveals three distinct modes of wire failure as capacitor charge voltage and energy deposition are increased. For 100 micron diameter gold-plated tungsten wires of 2 cm length, deposited energies of 1.9 eV/atom produces a liquid column that undergoes hydrodynamic breakup into droplets with radii of order of wire diameter on timescales of 200 μs. Instability growth, column breakup, and droplet coalescence follow classic Rayleigh-Plateau predictions for instability of viscous fluid column. Above 3.2 eV/atom of deposited energy, wires are seen to abruptly transition to an expanding mixture of micron scale liquid-droplets and vapor within one frame (less than 3.33 μs), which has been termed ‘phase explosion’ in literature. Between these two limits, at 2.5 eV/atom of deposited energy, wire radius is unchanged for the first 10 μs before the onset of a rapid expansion and disintegration that resembles homogenous nucleation of mechanically unstable bubbles. Here, thermodynamic calculations are presented that separate cases by temperature obtained during heating: below boiling point, near boiling point, and exceeding boiling point.

42 ENGINEERING↗

Electrically conductive proppant and methods for detecting, locating and characterizing the electrically conductive proppant

Electrically conductive proppants and methods for detecting, locating, and characterizing same are provided. The electrically conductive proppant can include a substantially uniform coating of an electrically conductive material having a thickness of at least 500 nm. The method can include injecting a hydraulic fluid into a wellbore extending into a subterranean formation at a rate and pressure sufficient to open a fracture therein, injecting into the fracture a fluid containing the electrically conductive proppant, electrically energizing the earth at or near the fracture, and measuring three dimensional (x, y, and z) components of electric and magnetic field responses at a surface of the earth or in an adjacent wellbore.

47 OTHER INSTRUMENTATION↗

Electrically conductive proppant and methods for detecting, locating and characterizing the electrically conductive proppant

Electrically conductive proppants and methods for detecting, locating, and characterizing same are provided. The electrically conductive proppant can include a substantially uniform coating of an electrically conductive material having a thickness of at least 500 nm. The method can include injecting a hydraulic fluid into a wellbore extending into a subterranean formation at a rate and pressure sufficient to open a fracture therein, injecting into the fracture a fluid containing the electrically conductive proppant, electrically energizing the earth at or near the fracture, and measuring three dimensional (x, y, and z) components of electric and magnetic field responses at a surface of the earth or in an adjacent wellbore.

Cannan, Chad↗