Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beta-gamma coincidence detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation of MCNPX-PoliMi code for simulations of radioxenon beta-gamma coincidence detection

Radioxenon detection is an important component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty. We developed and validated a new model in MCNPX-PoliMi to simulate the decay of various radioxenon isotopes and the detector response of a variety of detector types. The model was validated using calibration data from a plastic and NaI(Tl) beta-gamma coincidence detector and the results are presented. The results of this validation show that this model can also be used as a tool to produce training spectra and as a method to calibrate radioxenon detection systems.

Radioxenon analysis, MCNP, beta-gamma coincidence↗

A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty

Here in this work, a prototype radioxenon detection system was designed, developed and tested at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon radioisotopes for monitoring nuclear explosions. The detector utilizes two coplanar CZT detectors and measures xenon radioisotopes through beta-gamma coincidence detection between the two detection elements. The CZT-based detection system offers excellent energy resolution and background count rate compared with scintillator-based beta-gamma coincidence detectors currently in operation at the IMS stations. In this paper, we briefly discuss the detector design and report our recent measurement results with 131mXe, 133mXe, and 133Xe produced in the TRIGA reactor at OSU.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A prototype detection system for atmospheric monitoring of xenon radioisotopes

The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135 Xe and 133/133m Xe, have been detailed previously. This paper presents recent measurements of 133/133m Xe and 131m Xe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135 Xe, 133/133m Xe, and 131m Xe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m 3 for 131m Xe, 133 Xe, and 133m Xe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). Lastly, the system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.

36 MATERIALS SCIENCE↗

Absolute Efficiency Calibration of a Beta-Gamma Detector

Abstract- Identification and quantification of nuclear events such as the Fukushima reactor failure and nuclear explosions rely heavily on the accurate measurement of radioxenon releases. One radioxenon detection method depends on detecting beta-gamma coincident events paired with a stable xenon measurement to determine the concentration of a plume. Like all measurements, the beta-gamma method relies on knowing the detection efficiency for each isotope measured. Several methods are commonly used to characterize the detection efficiency for a beta-gamma detector. The most common method is using a NIST certified sealed source to determine the efficiency. A second method determines the detection efficiencies relative to an already characterized detector. Finally, a potentially more accurate method is to use the expected sample to perform an absolute efficiency calibration; in the case of a beta-gamma detector, this relies on radioxenon gas samples. The complication of the first method is it focuses only on the gamma detectors and does not offer a solution for determining the beta efficiency. The second method listed is not similarly constrained, however it relies on another detector to have a well-known efficiency calibration. The final method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The production, by University of Texas (UT), of isotopically pure radioxenon has allowed the beta-gamma detectors to be calibrated using the absolute efficiency method. The first four radioxenon isotope calibration will be discussed is this paper.

absolute efficiency calibration beta-gamma↗

Study of Shadowing in Beta-Gamma Coincidence Plots for Radioxenon

This document describes a study of the cause of shadowing observed in certain beta-gamma plots produced with beta-gamma coincidence detectors for detection of radioxenon. Beta-gamma detectors must possess adequate resolution to allow for the metastable isotopes 131m Xe and 133m Xe to be distinguished from each other and from 133 Xe. One effect that can minimize the ability to distinguish the metastables from 133 Xe is the shadowing effect, in which a band of high-energy signal is present in addition to the primary signal. A study was performed to determine the cause of the shadowing, and how to minimize the effect of the shadowing on an individual beta cell. Through this study, it is determined that the shadowing results from a difference in light transmission between the dome and end-cap portions of the beta cell. Consequently, it is not possible to remove the shadowing during the beta cell manufacturing process. The shadowing must be minimized by preferentially matching the light output from the end-cap and dome portion prior to the manufacturing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radioxenon detector calibration spike production and delivery systems

Abstract Beta-Gamma coincidence radioxenon detectors must be calibrated for each of the four-radioxenon isotopes (135Xe, 133Xe, 133mXe, and 131mXe). Without a proper calibration, there is potential for the misidentification of the amount of each isotope detected. It is important to accurately determine the amount of each radioxenon isotope, as the ratios can be used to distinguish between an anthropogenic source and a nuclear explosion. We have developed a xenon calibration system (XeCalS) that produces calibration spikes of known activity and pressure for field calibration of detectors. The activity concentrations of these calibration spikes are measured using a beta-gamma coincidence detector and a high purity germanium (HPGe) detector. We will present the results from the development and commissioning of XeCalS, along with the future plans for a portable spike implementation system.

beta-gamma coincidence detector↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A radioxenon detection system using PIPS and CZT

This paper introduces and describes the initial characterizations of a prototype beta gamma coincidence detection system that utilizes a PIPSBox and two coplanar CdZnTe detectors for atmospheric radioxenon identification and nuclear test ban treaty verification. Coincidences between four independent detecting bodies are identified in real time via a custom coincidence module implemented in a field-programmable gate array (FPGA). The system is compact, maintains simple readout electronics, and provides high resolution radiation detection at room temperature operation. Preliminary measurements using 137 Cs and 131m Xe were conducted to optimize various system parameters to achieve optimal energy resolution of key spectral features. The purpose of this research was to explore the utility of these materials and methods for radioxenon monitoring in the International Monitoring System (IMS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A ROBUST ABSOLUTE DETECTION EFFICIENCY CALIBRATION METHOD UTILIZING BETA/GAMMA COINCIDENCE SIGNATURES AND ISOTOPICALLY PURIFIED NEUTRON ACTIVATED RADIOXENON ISOTOPES

Efforts to calibrate the absolute efficiency of gas cell radiations detectors have utilized a number of methodologies which allow adequate calibration but are time consuming and prone to a host of difficult-to-determine uncertainties. A method that extrapolates the total source strength from the measured beta and gamma gated beta coincidence signal was developed in the 1960’s and 1970’s. It has become clear that it is possible to achieve more consistent results across a range of isotopes and a range of activities using this method. Even more compelling is the ease with which this process can be used on routine samples to determine the total activity present in the detector. Additionally, recent advances in the generation of isotopically pure radioxenon samples of Xe-131m, Xe-133, and Xe-135 have allowed these measurement techniques to achieve much better results than would have been possible before when using mixed isotopic radioxenon source. This paper will discuss the beta/gamma absolute detection efficiency technique that utilizes several of the beta-gamma decay signatures to more precisely determine the beta and gamma efficiencies. It will than compare these results with other methods using pure sources of Xe-133, Xe-131m, and Xe-135 and a Xe-133/Xe-133m mix.

Beta-gamma↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of portable, modular gas samplers as part of an atmospheric tracer experiment

Underground nuclear explosions release noble gases into the atmosphere that can be detected to support international monitoring efforts. Atmospheric transport models help predict the movement of these gases over long distances, but struggle to predict the movement in the atmosphere local to the release. A field experiment was designed to monitor the movement of 127 Xe within a 5-km radius. Four gas samplers were deployed as part of this experiment to collect atmospheric samples at various distances from the release point. In conclusion, these samples were then analyzed in a near-field lab using a NaI detector and in an off-site lab using gamma-gamma coincidence and beta-gamma coincidence counting.

Radioxenon↗