DOE OSTI · 1907598
A new algorithm for estimating radioxenon concentrations
Abstract
A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Eslinger, Paul W., Schrom, Brian T., Warren, Glen A.. 2022-12-22. A new algorithm for estimating radioxenon concentrations. https://doi.org/10.1016/j.jenvrad.2022.107094
Cite the original work for its findings. Save a collection to share your selection of sources.